- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Chauvin CA5001 Analogue Multimeter (No Case)
Includes: C.A 5001, leads with prods, 1x battery 1.5 V and user’s manual.
This product does not include the hard carry case. Customers requiring the case should see P01196521F.
The Chauvin Arnoux C.A 5001 multimeter is designed for the daily needs of professionals in electricity. It has the following functions: Voltmeter: voltage measurements (V DC and AC), Ammeter: current measurements (A DC and AC), Ohmmeter: resistance measurements (Ω), Continuity sound test.
It also allows the measurement of decibel levels (dB), on the AC voltmeter ranges. The dial has a fuse test light (Fus.).
The analogue dial comprises 6 scales: 2 black scales, with antiparallax mirror, for V DC and AC (0.100 and 0.30), 1 green scale for Ω (0.10k), 1 black scale for A DC (0.50), 1 red scale for A AC (0.50), 1 red scale for dB (0.22).
FEATURES
Neon testing for the 0.5A and 5A fuses on current measurement.
24 position switch to select functions and ranges.
Zero reset button on ohmmeter.
DC and AC current testing.
2 resistance ranges (x1 and x100).
Continuous audible beep emitted for a resistance R < 50 Ω.
Compact shockproof case with multi-purpose articulated stand.
DC voltage | 8 ranges: 100 mV ... 1000 V. |
AC voltage | 5 ranges: 10 V ... 1000 V. |
Internal resistance | 20 kΩ/V. |
Working frequency | 10 Hz ...100 kHz depending on range. |
DC current | 5 ranges: 50 μA ... 5 A. |
AC current | 4 ranges: 5 mA ... 5 A. |
Resistance | 2 ranges: 10 kΩ and 1 MΩ. |
Audible continuity test | R < 50 Ω. |
Scale in dB for V AC | 0 ... +22 dB. |
Typical accuracy (3) | 1.5% on V DC • 2.5 % on V AC and A AC/DC • 10 % on Ω. |
Power supply | 1 battery 1.5 V. |
Battery life | 10,000 measurements of 15 s. |
Electrical safety | IEC 1010-1 - 600 V/Cat III. |
Protection | HBC fuses 0.5 A and 5 A. |
Degree of watertightness | IP 40. |
Environmental conditions | -10°C ... + 55°C and RH < 90 %. |
Dimensions | 160 x 105 x 56 mm. |
Weight | 500 g. |
(1) Additional “VoltestTM ” function to check the possible presence of voltage on resistance and audible continuity test. (2) Limited to 240 A max by the miniclamp MN 89. (3) In % of end of scale. (4) Degree of pollution 2 - (5) Electronic protection and HBC fuses for the current ranges with fuse test light. |