Amprobe HD160C Heavy-Duty Digital Multimeter
Includes: Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA-1A) and User Manual.
The Amprobe HD160C digital multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistance to at least eight feet.
The HD160C is a heavy-duty 4-digit, autoranging, AC-coupled True RMS measuring instrument that measures voltage, current, resistance, continuity, as well as capacitance, frequency and temperature. It also offers Range Lock, Data Hold, Relative Measurement, Auto Min Max Measurement, a bright backlight, and Auto Power Off to save battery life. The instrument is completely o-ring sealed to pass strict IP-67 ratings for moisture and dust proof. The HD160C meets the highest safety rating of CAT IV 1000 V (1500V DC max).
FEATURES
Highest voltage capability, measuring to 1500 Vdc and 1000 Vac.
CAT IV 1000 V rated.
Special sealing for environment and water resistance. IP67 rated.
Constructed with drop-resistant housing and PCB mounting.
Measures capacitance, temperature and frequency.
Superior 10,000 count resolution with bar graph.
Magne-Grip™ holster, frees both hands for workIncludes high voltage test leads with threaded alligator clips.
Temperature measurement built-in.
Frequency and capacitance.
Digi-Glo™ bright backlight.
General Specifications | |
---|---|
Display | 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. |
Polarity Indication | Automatic. |
Input Overload Indication | OL, -OL. |
Low Battery Indication | Symbol at less than 50 hours battery life remaining (accuracy no longer guaranteed) |
Display Update Rate | 2/sec nominal; 20/sec for bargraph |
Operating Temperature | 0 to +50°C @ 0 to 75% RH. |
Storage Temperature | -20 to 60°C @ 0 to 80% RH, battery removed. |
Temperature Coefficient | 0.1 x (spec. accuracy)/°C (0 to 18°C and 28 to 50°C). |
Fuse | F 2A/1500V fuse (8mm x 65mm), I.R. 30kA - Amprobe p/n FP700. |
Power | Standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22. |
Auto Power Down | Meter powers down after approximately 30 minutes of inactivity. Not in MIN/MAX function. |
Battery Life (typical) | 150 hours, alkaline. Backlight usage consumes extra power and will decreased battery life significantly. Backlight auto off after approx 60 seconds. |
Dimensions (without holster) | 200 x 102 x 59mm (7.9 x 4.0 x 2.3") - H x W x D. |
Weight (Incl. Battery) | 642g (22oz). |
Case material | Reinforced, high-impact, fire retardant thermoplastic. |
Safety | Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67. |
EMC | Meets EN 61326-1. |
Electrical Specifications (Accuracy at 23 °C ± 5 °C, Accuracy at 23 °C ± 5 °C, <75 % RH, guaranteed for one year) | |
DC Voltage | |
Ranges | 1000mV, 10V, 100V, 1500V. |
Resolution | 0.1mV in 1000mV range. |
Accuracy | ±(0.1% rdg + 5 digits). |
Input Impedance | 10MΩ. |
CMRR | >120dB up to 1500V DC. |
NMRR | >60dB at 50/60Hz. |
OL Protection | 1500V DC or 1000V AC RMS. |
Transient Protection | 12kV impulse (1.2μS/50μS) based on EN 61010-1:2001 impulse requirements for CAT IV 1000V/1500V DC products. This product should not be used in installations where transients exceed 12kV. |
AC Voltage (True RMS) | |
Ranges | 1000mV, 10V, 100V, 1000V. |
Resolution | 0.1V in 1000mV range. |
Accuracy | 1000mV (45 to 400Hz): ±(1.2% rdg + 10 digits) 10V, 100V (45 to 500Hz): ±(1.2% rdg + 10 digits) 10V, 100V (500Hz to 2kHz): ±(2.0% rdg + 10 digits) 1000V (45 to 1kHz): ±(2.0% rdg + 10 digits) |
Input Impedance | 10MΩ. |
Conversion Type | True RMS, AC coupled 5% to 100% of range. |
Crest Factor | ≤3 |
OL Protection | 1500V DC or 1000V AC RMS. |
Transient Protection | 12kV impulse (1.2μS/50μS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV. |
DC Current | |
Ranges | 100μA, 1000μA, 10mA, 100mA, 400mA, 2A (auto/manual ranging). |
Resolution | 0.01μA in 100μA range. |
Accuracy | 100μA range: ±(0.5% rdg + 10 digits) 1000μA to 400mA ranges: ±(0.5% rdg + 5 digits) 2A range: ±(1.5% rdg + 10 digits). |
Input Protection | 2A/1500V fast blow ceramic fuse 8 x 65mm on A input, FP700. |
Burden Voltage | μA range of 1mV/1μA, mA range of 10mV/1mA, 2A range of 500mV/1A, 500mV max. (2V max on 1000μA, 100mA, 400mA, 2A ranges). |
OL Protection | A input (F 2A/1500V, size 8 x 65mm IR fast blow ceramic). |
AC Current (True RMS) | |
Ranges | 100μA, 1000μA, 10mA, 100mA, 400mA, 2A. |
Resolution | 0.01μA in 100μA range. |
Accuracy (45 to 1kHz) | 100μA to 100mA: ±(1.5% + 10 digits) 400mA: ±(2.0% + 10 digits) 2A: ±(2.5% + 20 digits). |
Voltage Burden | See DC current. |
Conversion Type | True RMS AC couple 10 to 100% of range. |
Crest Factor | ≤3. |
OL Protection | See DC current. |
Resistance | |
Ranges | 1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ. |
Resolution | 0.1Ω in 1000Ω range. |
Accuracy | 1000Ω to 1000kΩ: ±(0.5% rdg + 8 digits) 10MΩ: ±(1.0% rdg + 10 digits) 40MΩ: ±(2.0% rdg + 10 digits). |
Overload Protection (All Ranges) | 1500V DC or 1000V AC RMS. |
Continuity | |
Audible Indication | Less than 40Ω. |
Response Time | 100ms. |
Overload Protection | 1500V DC or 1000V AC RMS. |
Capacitance | |
Ranges | 40nF, 400nF, 4μF, 40μF, 400μF (3999 counts) - auto/manual ranging. |
Resolution | 0.01nF. |
Accuracy | 40nF, 400μF: ±(3.0% rdg + 10 digits) 400nF to 40μF: ±(3.0% rdg + 5 digits). |
Test Voltage | <1V. |
Test Frequency | 1.3Hz on 40nF to 40μF ranges; 0.7Hz on 400μF range. |
Overload Protection | 1500V DC or 1000V AC RMS. |
Temperature | |
Ranges | -20 to 1300°C (-4 to 2372°F). |
Resolution | 1°C, 1°F). |
Accuracy | -20 to 10°C: ±(2.0% rdg + 4°C) 10 to 200°C: ±(1.0% rdg + 3°C) 200 to 1300°C: ±(2.0% rdg + 2°C). |
Frequency | |
Ranges | 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz. |
Resolution | 0.01Hz on 100Hz range. |
Accuracy | ±(0.1% rdg + 5 digits). |
Sensitivity | 3Hz to 1mHz: >2.5V AC RMS 1mHZ to 10mHZ: >2.5V AC RMS, <5V AC RMS. |
Minimum Input Range | 100Hz range: >3Hz 1000Hz range: >30Hz. |
Minimum Pulse Width | >25ns. |
Duty Cycle Limits | >30% and <70%. |
Overload Protection | 1500V DC or 1000V AC RMS . |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
TL1500 | Cat IV 1000 V Test Leads with Alligator Clips. | 2696277 | ||
CT235A | 1000 A ac/dc Clamp. | 3026809 | ||
VC221B | Padded Vinyl Case. Fits meter & holster. | 3068271 | ||
FP700 | Replacement Fuse, 2 A/1500 V, pack of two. | 2637713 |