- Reduced price
- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Testo 340 Flue Gas Analyser (Basic Combustion Kit)
Includes: testo 340 flue gas analyser, calibration certificate, shoulder strap, O2, CO, NO sensors fitted, AC power supply.
The testo 340 combustion analyser is an easy-to-use combustion gas analyser designed for commercial and industrial applications that can be fitted with up to four different gas sensors. This 'basic combustion' kit includes sensors for O2, CO, and NO.
The handy, easy-to-operate testo 340 is the right tool for many different emission measurements. The compact design and the reliable technology make it the ideal measuring instrument for commissioning, service and maintenance work and in test measurements on industrial burners, stationary industrial engines, gas turbines and thermal processes.
The testo 340 analysers compact and robust design increases mobility and makes it ideal for daily servicing and carrying out measurement checks. High gas concentrations are no problem for the testo 340, with an extended measuring range via sample dilution the gas sensor is not subjected to any higher stress levels than low gas concentrations, this ensure the sensor has the longest possible service life.
The instrument can also be operated remotely from your Android Smartphone or tablet using the free App.
FEATURES
Flue gas analysis with up to 4 gas sensors – freely configurable.
Large selection of probes.
Bluetooth interface.
Convenient measurement data management.
TÜV-tested /EN norm.
(*note - kit does not include sampling probe - to be selected dependent on application).
Differential Pressure - Piezoresistive | |
---|---|
Measuring range | -200 to 200 hPa. |
Accuracy | ±0.5 hPa (-49.9 to 49.9 hPa) ±1.5 % of mv (Remaining Range). |
Resolution | 0.1 hPa. |
Absolute Pressure | |
Measuring range | +600 to +1150 hPa. |
Accuracy | ±10 hPa. |
Resolution | 1 hPa. |
Flue gas O₂ | |
Measuring range | 0 to 25 Vol.%. |
Accuracy | ±0.2 Vol.%. |
Resolution | 0.01 Vol.%. |
Reaction time t₉₀ | < 20 s. |
Flue gas CO (with H₂-compensation) | |
Measuring range | 0 to 10000 ppm. |
Accuracy | ±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 10000 ppm). |
Resolution | 1 ppm. |
Reaction time t₉₀ | < 40 s. |
Flue gas COlow | |
Measuring range | 0 to 500 ppm. |
Accuracy | ±2 ppm (0 to 39.9 ppm) ±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K. |
Resolution | 0.1 ppm. |
Reaction time t₉₀ | < 40 s. |
Flue gas NO | |
Measuring range | 0 to 4000 ppm. |
Accuracy | ±5 ppm (0 to 99 ppm) ±5 % of mv (100 to 1999 ppm) ±10 % of mv (2000 to 4000 ppm). |
Resolution | 1 ppm. |
Reaction time t₉₀ | < 30 s. |
Flue gas Nolow | |
Measuring range | 0 to 300 ppm. |
Accuracy | ±2 ppm (0 to 39.9 ppm) ±5 % of mv (Remaining Range). |
Resolution | 0.1 ppm. |
Reaction time t₉₀ | < 30 s. |
Flue gas NO₂ | |
Measuring range | 0 to 500 ppm. |
Accuracy | ±10 ppm (0 to 199 ppm) ±5 % of mv (Remaining Range). |
Resolution | 0.1 ppm. |
Reaction time t₉₀ | < 40 s. |
Flue gas SO₂ | |
Measuring range | 0 to 5000 ppm. |
Accuracy | ±10 ppm (0 to 99 ppm) ±10 % of mv (Remaining Range). |
Resolution | 1 ppm. |
Reaction time t₉₀ | < 40 s. |
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded. | |
Differential Pressure flue gas Draught - Piezoresistive | |
Measuring range | -40 to +40 hPa. |
Accuracy | ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (Remaining Range). |
Resolution | 0.01 hPa. |
Temperature | |
Measuring range | -40 to +1200 °C. |
Accuracy | ±0.5 °C (0 to +99 °C) ±0.5 % of mv (Remaining Range). |
Resolution | 0.1 °C. |
Flue gas degree of effectivity, Eta (calculated) | |
Measuring range | 0 to 120 %. |
Resolution | 0.1 %. |
Flue gas loss (calculated) | |
Measuring range | 0 to 99.9 %. |
Resolution | 0.1 %. |
Flue gas dewpoint (calculated) | |
Measuring range | 0 to 99.9 °Ctd. |
Resolution | 0.1 °Ctd. |
Flue gas CO₂ calculation (calculated from O₂) | |
Measuring range | 0 to CO₂ max. |
Accuracy | ±0.2 Vol.%. |
Resolution | 0.1 Vol.%. |
Reaction time t₉₀ | < 40 s. |
General technical data | |
Weight | 960 g. |
Dimensions | 283 x 103 x 65 mm. |
Operating temperature | -5 to +50 °C. |
Product-/housing material | TPE PC. |
Protection class | IP40. |
Product colour | Black. |
Connectable probes | 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure. |
Battery life | > 6h (Pumpe an, Displaybeleuchtung aus, bei 20°C). |
Display type | Graphic display. |
Display size | 160 x 240 pixels. |
Display function | Graphic display. |
Power supply | Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A. |
Max. neg. press./flue gas | -200 mbar. |
Max. pos. press./flue gas | 50 mbar. |
User defined fuels | 10 user-defined fuels incl. test gas as fuel. |
Hose length | max. 7.8 m (corresponds to two probe hose extensions). |
Pump flow | 0.6 l/min (regulated). |
Maximum memory | 100 folders. |
Storage per folder | Max. 10 sites. |
Storage per site | Max. 200 logs. |
Miscellaneous | The max. number of logs is determined by the number of folders or sites. |
Interface | Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure. |
Storage temperature | -20 to +50 °C. |
No customer reviews for the moment.
COMPONENT | DESCRIPTION | PART No. | ||
Industrial Probe Set 1 | Enables the extractive sampling of flue gas analysed at high flue gas temperatures (up to 1 200 °C) or for applications involving large flue gas pipe diameters. | 0600 7610 | ||
Pitot Tube 350 mm | Stainless steel Pitot tube, length 350 mm, Ø 7 mm - for measuring flow velocity. | 0635 2145 | ||
Pitot Tube 1000 mm | Stainless steel Pitot tube, length 1000 mm, Ø 7 mm - for measuring flow velocity. | 0635 2345 | ||
Air Temp Probe | Combustion air temperature probe, immersion depth 60 mm. | 0600 9797 | ||
Hose Extension | Probe-instrument extension hose (length 2.8 m). | 0554 1202 | ||
Fast Printer | Testo fast printer IRDA. | 0554 0549 | ||
International Mains Unit | For mains operation or charging batteries in the instrument. 100-240 V AC / 6.3 V DC. | 0554 1096 | ||
Emission Software | The testo easyEmission PC software offers numerous functions for convenient measurement data management. | 0554 3334 |