- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
TPI 716 Flue Gas Combustion Efficiency Analyser
Includes: TPI 716 Analyser, Rubber Boot (A765), Soft Carrying Case (A768), Flue Sampling Probe, In-Line Filter / Water Trap installed on Flue probe, Temperature Probe, Battery Charger, Mini Pump Protection Filter Assembly, Exhaust Spigot Removable, Pressure Adapters 1 pair, PC Software and cable for communication to a PC, Instruction Manual.
The feature rich, but still easy-to-use, TPI 716 Deluxe Flue Gas Combustion Efficiency Analyser is designed to meet the needs of the busiest gas heating engineer and installer. The TPI 716 not only displays and calculate the required readings from a flue but also covers most of the other measurements associated with combustion.
The instrument is ruggedly constructed and comes with a 6 Year Guarantee subject to annual servicing being carried out by TPI or one of their approved service centres.
FEATURES
Long life O2 sensor.
In-line water trap bowl filter to prevent water ingress.
In-line mini pump protection filter to prevent a blocked pump caused by dust/dirt ingress.
Multi-fuel.
View pressure and gas at same time.
Timed Let/By & Tightness test.
Timed CO Build-Up room test.
Large 4 or 8 Line Graphical Display.
Upgradeable to take NOx readings.
Upgradeable to take High CO readings.
Re-Chargeable NiMH battery.
Readings output to (Optional) IR printer.
Operating Temperature Range | 14°F to +122°F (-10°C to +50°C). | ||
Battery/Battery Life | Rechargeable NiMH / > 6 hours. | ||
Charger Input Voltage | 115V or 230V: 50/60Hz AC. | ||
Fuels | Natural gas, LPG, light oil, heavy oil, bituminous coal, anthracite coal, coke, butane, wood, bagasse. | ||
Units of Pressure | mbar, kPa, and inH20. | ||
Display | 8 line graphical LCD (backlit). | ||
Data Storage | 100 sets of readings. | ||
Data Logging | 400 sets of readings. | ||
Single Logging | 150 sets of readings. | ||
Time and Date | 24 hour real time clock. | ||
Dimensions | 7.8 x 3.5 x 2.4". | ||
Weight | 1.1lbs. | ||
Measurement Ranges | |||
---|---|---|---|
Gas | Range | Resolution | Accuracy |
Oxygen | 0-25% | 0.1% | ±0.3% |
Carbon Monoxide | 0-10000ppm | 1ppm | ±5ppm or 5% |
Carbon Dioxide | 0-25% | 0.1% | Calculated |
CO/CO2 Ratio | 0-0.999 | 0.001 | Calculated |
Combustion Efficiency | 0-100% | - | Calculated |
No customer reviews for the moment.