loading spinner
  • On sale!
Chauvin C.A 1950 DiaCAm 2
  • Chauvin C.A 1950 DiaCAm 2
  • Chauvin C.A 1950 DiaCAm 2
  • Chauvin C.A 1950 DiaCAm 2

Chauvin C.A 1950 DiaCam 2

chauvin arnoux authorised distributor.

Includes: C.A 1950, delivered in hard case with 4 NiMH batteries and battery charger, 1 micro SD HD card, 1 USB cable, 1 set of Bluetooth earphones, CAmReport software on CD ROM, operating manuals.

P01651901
£950.00
£760.00 Save 20%
Tax excluded
Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

The C.A 1950 makes it very simple to perform your thermal inspections for your energy audit and ensures trouble-free industrial, electrical or mechanical maintenance. The C.A 1950 is a communicating camera which can recover the necessary measurements (current, etc.) from current clamps and multimeters via Bluetooth.

The Diacam2 C.A 1950 is a powerful tool for analysing new or old buildings. This thermal camera enables you to detect faults and anomalies such as, thermal bridges, insulation faults on the exterior of a building, draught-proofing, presence of excessive humidity. The C.A 1950 can also be used to search for water leaks and detect embedded or blocked pipes.

ELECTRICAL MAINTENANCE

For electrical maintenance, the C.A 1950 can detect electrical equipment malfunctions, particularly abnormal heating, before a fault occurs, thus avoiding the considerable cost of halting production or carrying out repairs: Faulty electrical contacts; Unbalance; Incorrect sizing.

MECHANICAL MAINTENANCE

For mechanical maintenance, the C.A 1950 is ideal, offering quick diagnostics thanks to: detection of anomalies or malfunctions on internal components to prevent motor overheating, verification and inspections on the parts and mechanical assemblies such as: wear points, poor shaft alignment, lubrication problems and adjustment errors.

REPORT CREATION

Report creation is automatic, using the various templates available. Reports can be exported in Word or pdf format. This makes it simpler to print them out and/or archive them.

FEATURES

Exceptional 13-hour battery life.
Quick startup in under 3 seconds.
Focus-free with 20° x 20° field of view.
Emissivity table which can be enhanced as required.
Possibility of renaming the images and thermograms by site.
Recording and storage of the configurations according to the different applications (building, electrical cabinet, etc.).
Vocal annotations to record your comments directly on the image.
Connection to current clamps and multimeters: all the necessary measurements simultaneously.

The DiaCam2 has a 20° x 20° field of view with focus-free imaging. The image is automatically in focus whatever the distance to the object targeted. With a wide 2.8-inch screen and more comfortable viewing thanks to automatic (or manual) adaptation of display brightness to suit your environment.

Chauvin CA 1950 Product Video

Chauvin C.A 1950 Specifications
Detector80 x 80.
TypeUFPA microbolometer, 8 ~14 μm.
Frequency9 Hz.
Sensitivity (N.E.T.D)
80 mK @ 30°C (0.08 °C @ 30 °C).
Temperature range-20 °C to +250 °C.
Accuracy±2 °C or ±2 % of reading.
Field of view20° x 20°.
IFOV (spatial resolution)4.4 mrad.
FocusFixed.
Minimum focal distance40 cm.
Real imageYes (320 x 240 pixels).
Display modeThermal image, real image with automatic parallax compensation. Merging of both images possible with PC software.
Measurement tools
1 manual cursor + 1 automatic detection + Min-Max on adjustable area + temperature profile + Isotherm.
Parameter settingsEmissivity, environmental temperature, distance, relative humidity.
Vocal commentsYes via Bluetooth (earphones provided).
ConnectivityF407 and F607 clamps, MTX 3292 and MTX 3293 multimeters.
Data storageOn 2 GB micro SD card (approx. 4,000 images) removable up to 32 GB.
Removable, up to 32 GB.bmp (thermal and real images recorded simultaneously).
AdjustmentAutomatic or manual adjustment of palette min-max.
Freezing of imageAnimated or fixed image.
Image displayMulti-palette.
Screen2.8 inches.
PowerNiMH rechargeable batteries with low self-discharge.
RechargingExternal (charger provided).
Operating temperature-15 °C to +50 °C (-4 °F to +122 °F).
Storage temperature-40 °C to +70 °C (-40 °F to +158 °F).
StandardsEN 61326-1: 2006 / EN 61010-1 Ed.2.
Fall resistance2 metres on all surfaces.
Ingress protectionIP 54.
InterfacesUSB link and Mass Storage function
Bluetooth for connectivity with earphones (vocal comments) and Chauvin Arnoux Metrix measuring instruments.
Tripod mountingYes with ¼" insert on the camera.
Report creation softwareSupplied as standard with automatic report generation.
Dimensions225 x 125 x 83 mm.
Weight700 g with rechargeable batteries.
C.A 1950 warranty2 years.

Download

Chauvin CA 1950 Datasheet

PDF Specifications of the Chauvin Arnoux C.A1950 DiaCAm2 Thermal Imager.

Download (1019.53k)

No customer reviews for the moment.