Fluke 5627A-12-X Precision Industrial RTD Probe

Fluke Calibration

Fluke Calibration authorised distributor.

The Fluke 5627a RTD temperature probe is an excellent value for a precision thermometer. It has the price-to-accuracy and price-to-durability ratios you should demand in all of your precision thermometers.

More details

3055537

New

Delivery TBC

£ 536.00

(£ 643.20 inc VAT.)

Add to wishlist

The Platinum Resistance Thermometer (PRT) models 5627A is designed to be a secondary standard interpolating instrument converting temperature to resistance. The 5627A may also be used as a temperature standard for calibration of industrial sensors. The PRT is used with a readout device to detect temperature changes or actual temperature.

The Fluke 5627A-12-X is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order).

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer, lab code 200706-0.

Please Note: When ordering please specify the termination you require. ie. Fluke 5627A-12-G (gold pins), plus the Bending Radius required.

X = termination.

Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “I" (INFO-CON for 1521 or 1522), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

FEATURES:

Secondary PRT, 305 mm x 6.35 mm (12 in x 1/4 in), –200 °C to 420 °C.
Vibration and shock resistant.
NVLAP-accredited calibration included, lab code 200706-0.
Bending Radius: Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip.

Fluke 5627A-12-X Specifications:

  • Resistance: Nominal 100 Ω.
  • Temperature Coefficient: 0.00385 Ω/Ω/ °C nominal.
  • Temperature Range: −200 °C to 420 °C.
  • Drift Rate (k=2): ± 0.04 °C at 0 °C after 100 hours at 420 °C.
  • Sheath Material: 316 Stainless Steel.
  • Leads: PTFE-insulated, nickel-plated stranded copper, 22 AWG.
  • Immersion: At least 100 mm (4 in) recommended.
  • Bending Radius: See above.
  • Size: 305 mm x 6.35 mm (12 in x 1/4 in).
  • Calibration: Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration.
  • Fluke Calibration 5627A Warranty: 1 year.