Kewtech KT5 Open Jaw Current & Voltage Tester
Includes: Kewtech KT5 tester, Manual & Batteries.
The ultimate in everyday electrical tools, including all modes of volatge detection and an open jaw current measurement capability which enables you to detect open PEN situations.
FEATURES
Non contact voltage detection with three sensitivity levels.
Single pole volatge detection - works on either probe.
Traditional two pole voltage detection with clear backlit LED indication and LCD readout.
Three sensory outputs for voltage indication - buzzer, vibration and LED/LCD.
Resistance and continuity buzzer.
DMM functions.
Phase rotation.
Probe tip cover with nose to depress the earth pin in traditional UK BS1363 socket outlets.
Convenient probe storage in body.
Kewtech KT5 Open Jaw Current & Voltage Tester Specifications
Voltage Range | 1…1000V AC (15…800Hz), 1…1500V DC(±). |
LED nominal Voltage | 120 /230/400/690/1000V. |
LED tolerances | EN 61243-3. |
ELV indication LED | >50V AC, >120V DC. |
Response time | <1s at 100% of each nominal value. |
LCD Range | 1…1000V, AC (15…800Hz), 1…1500V DC(±). |
LCD Resolution | 0.1V (1…29.9V), 1V (30…1500V). |
LCD Accuracy | ±3% ±1.5V (1…29.9V) ±3% ±3dgt (30…1500V). |
LCD Overrange indication | “OL”. |
Current Test | 0.1…200A AC(+/-3%+5dgt). |
Resolution 0.1A. | |
Frequency range 45…65Hz. | |
Safety current | Is<3.5mA (at 1000V AC), <6mA at 1500V DC. |
Measurement Duty | 30 s ON, 240s OFF. |
Internal battery consumption | approx. 120mA. |
Single-pole phase test voltage range | 100…1000V AC (50/60Hz ). |
Phase rotation test | 170…1000V phase-to-phase, AC (40...70Hz). |
Continuity test | 0…500 kΩ + 50%. |
Resistance measurement | 0…100 kΩ; accuracy: ±5%±10dgt@25°C; resolution: 1 Ω (1-2000 Ω) 1 kΩ (2-100 kΩ). |
Frequency measurement | 1…800 Hz ±5%±5dgt; resolution: 1Hz. |
NCV Test | 100...1000V AC (50/60Hz). |
Battery | 3V (IEC LR03 1.5V x 2) |
Temperature | -15…55°C operation; -20…70°C storage; No condensation. |
Humidity | max. 85% RH. |
Altitude | up to 2000m. |
Overvoltage | CAT IV/600V, CAT III/1000V. |
Standard | EN/IEC 61243-3:2014. |
Protection | IP64. |
Dimensions | 215(L) x 60(W) x 40mm(D). |
Weight (Instrument) | Approx: 260 g. |
Kewtech KT5 warranty | Two-years. |