Includes: ii910 Imager, AC power supply and battery pack charger (including universal AC adapters), two rugged lithium ion smart battery packs, USB cable, rugged, hard carrying case, two rubber array covers, adjustable hand strap and adjustable neck strap.

5233904
£18225.80
£21870.96 Inc. VAT
In Stock

Leaks in compressed air, gas and vacuum systems hit both production uptime and the operations bottom line.

While most manufacturers know that these types of leaks exist, it has been too time consuming and tedious to address them until now. With the Fluke ii900 or ii910 and minimal training, your maintenance technicians can begin checking for leaks during their typical maintenance routine - even during peak operation hours.

The ii900 series acoustic imagers let technicians see sound as they scan hoses, fittings, and connections for leaks. Its built-in acoustic array of tiny sensitive microphones generates a spectrum of decibel levels per frequency. Based on this output, an algorithm calculates a sound image, known as SoundMap™ that is superimposed on a visual image. The SoundMap is automatically adapted depending on the frequency level selected so that background noise is filtered out, making it incredibly simple to detect compressed gas leaks.

The Fluke ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting and maintaining power distribution and industrial high voltage equipment. The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events.

With the SoundSight™ technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas. The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning and is why the ii910 has a frequency range of 2-100Khz.

FEATURES

Do more with the same air compressors – delay the capital expense of installing an additional compressor.
Ensure proper air pressure to your pneumatic equipment.
Lower energy costs.
Reduce leak detection time
Improve reliability in your production line.
Make leak detection part of your typical maintenance routine.
Train the team in a matter of minutes.
Validate repairs on the spot.

Fluke ii910 Precision Acoustic Imager

Fluke ii910 Specifications
Sensors
Frequency band 2 kHz to 100 kHz.
Detection range .5 m to 120 m (1.6 to 393 feet)*.
Field of view 63°± 5°.
Nominal frame rate 25 FPS.
Built-in digital camera (visible light)
Field of view (FOV) 63°± 5°.
Focus Fixed lens.
Display
Size 7" LCD with backlight, sunlight readable.
Resolution 1280 x 800 (1,024,000 pixels).
Touchscreen Capactive.
Acoustic image Yes, SoundMap™ image.
Image Storage
Storage capacity Internal memory with the capacity for 999 picture files and 20 video files.
Image format Blended visual and SoundMap™.JPG or .PNG.
Video format Blended visual and SoundMap™.MP4.
Video length Up to 5 minutes.
Digital Export USB-C for data transfer.
Acoustic Measurements
Measurement range 12.1 dB SPL to 114.6 dB SPL
±1 dB SPL 2 kHz
4.4 dB SPL to 101.2 dB SPL
±2 dB SPL 19 kHz
12.8 dB SPL to 119.2 dB SPL
±1 dB SPL 35 kHz
19.8 dB SPL to 116.1 dB SPL
±3 dB SPL 52 kHz
41.4 dB SPL to 129.0 dB SPL
±1 dB SPL 80 kHz
54.4 dB SPL to 135.5 dB SPL
±1 dB SPL 100 kHz.
Auto max/min dB gain Auto or manual, user selectable.
Frequency band selection User selectable through user-made presets or manual entry.
Software
Ease of use Intuitive user interface.
Trend graphs Frequency and dB scale.
Spot markers dB level reading at center point of the image.
Battery
Batteries (field-replaceable, rechargeable) x Rechargeable Li-ion, Fluke BP291.
Battery life 6 hours/battery (product includes spare battery).
Battery charging time 3 hours.
Battery charging system External dual-bay charger, EDBC 290.
Safety
General safety IEC 61010-1.
Electromagnetic Compatibility (EMC) Int. IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A.
General Specifications
Standard palettes 3: Grayscale, Ironbow and Blue-Red.
Operating temperature -10 °C to 40 °C (14 °F to 104 °F).
Storage temperature -20 °C to 70 °C ( -4 °F to 158 °F) without batteries installed.
Relative humidity 10 % to 95 % non-condensing.
Ingress Protection (IP) IP40 (Protection against particles 1 mm or greater and dripping water).
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese.
RoHS compliant Yes.
Self-diagnostic notification Array-health test to identify when microphone array needs attention.
Size (H x W x L) 186 x 322 x 68 mm (7.3 x 12.7 x 2.7 inches).
Weight (battery included) 1.7 kg (3.75 pounds).
Fluke ii910 warranty 2 year.
*Depending on ambient conditions.