loading spinner
Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer
  • Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer
  • Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer
  • Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer

Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer

fluke Approved distributor

lead time   Lead Time Approx. 7-14 Days.


Includes: NVLAP-accredited report of calibration, Fluke 1552A-12 User’s Guide on CD-ROM, 3 AAA batteries.

3936070
Options

The Fluke 1552A “Stik” Thermometer is accurate, stable and durable, making it the best alternative to mercury thermometers and existing electronic thermometers. The thin-film RTD sensor incorporates the same characteristics of other premium reference thermometers designed by Fluke calibration, but it is more robust and less susceptible to drift.

The stainless steel probe sheath of the “Stik” Thermometer is far more robust than the glass stem of a mercury thermometer and better suited for industrial environments. And since the “Stik” thermometer does not contain mercury, the risk of an accidental mercury spill is eliminated.

The digital display and probe are fixed together as a system. The hinge allows the display to rotate 90° to easily view the measurement from any angle.

FEATURES

Accuracy of ± 0.05 °C (± 0.09 °F) over full range.
Intrinsically safe (ATEX and IECEx compliant).
User-configurable temperature Trend/Stability indicator.
Display temperature in °C or °F.
Optional data logging to internal memory.
300-hour battery life.
Percent battery-life and low-battery indicator.
NVLAP-accredited, NIST-traceable calibration included.

Fluke 1552A Specifications
Temperature Range -80 °C to 300 °C (-112 °F to 572 °F).
Accuracy (1 year) ± 0.05 °C (± 0.09 °F).
Display units °C, °F.
Sensor type 10Ω wire-wound PRT.
Probe temperature coefficient 0.00385 Ω/Ω/ΩC nominal.
Sensor length ≤ 30 mm.
Sensor position (from sheath tip) 3 mm (0.1 in).
Minimum immersion depth 12 cm (4.8 in).
Probe sheath material Stainless steel.
Response time 4.8 mm diameter probe (3/16 in): 14 seconds
6.35 mm diameter probe (1/4 in): 21 seconds.
Probe hysteresis ± 0.01 °C.
Temperature resolution Selectable: 0.1, 0.01, 0.001 (default 0.01).
Sample rate Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds).
Operating temperature range readout -10 °C to 50 °C (14 °F to 122 °F).
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) 0 % to 95 % RH, non-condensing.
Optional data logging1 Up to 10,000 time-stamped readings stored to internal memory.
Logging intervals1 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds;
2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes
Damping Moving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10).
Communications RS-232 stereo jack (access calibration parameters only).
AC power None.
DC Power 3-AAA Batteries, typical battery life of 300 hours without LCD backlight.
EMC compliance EN61326:2006 Annex C; CISPR II Edition 5.0-2009; Class “B.
Enclosure rating IP50.
Electronics dimensions (H x W x D) 114 mm x 57 mm x 25 mm (4.5 in x 2.25 in x 1.0 in).
Weight 196 g (6.9 oz).
Calibration (included) NVLAP-accredited, NIST-traceable.
Characterisation ITS-90.
Fluke 1552A warranty 1 year.
1. For Data-Logging option, please choose the 1552A-12-DL option from the dropdown.

Download

Fluke 1551A-1552A Datasheet

PDF Specifications of the Fluke 1551A/1552A 'Stik' Thermometer.

Download (364.68k)

No customer reviews for the moment.

Write your review

Fluke 1552A-12 Intrinsically Safe 'Stik' Thermometer
COMPONENT
DESCRIPTION PART No.
1551-CASE Carrying case (155x). 3624160
1551-CBL RS-232 cable (155x). 3936096

8 other products in the same category:

arrow_upward