testo Saveris 2 T2 WiFi Data Logger
Includes: testo Saveris 2-T2 WiFi data logger, Including free Cloud access (basic functionality), Micro USB cable, Wall bracket with lock, Batteries (4 x AA AlMn Mignon batteries), Short instructions, Calibration protocol.
The WiFi data logger testo Saveris 2-T2 allows you to monitor the temperatures and door contacts in refrigerated and work- or storerooms. The temperature values and door contacts measured with the connectable probes are reliably recorded over long periods, and transmitted directly to the Testo Cloud (online data store) via your WiFi. You can access these readings at any time, anywhere, using your internet-enabled smartphone, tablet or PC.
The temperature monitoring system consists of at least one WiFi data logger and a Cloud access (online data store). As a component of this data logger system, the testo Saveris 2-T2 data logger with up to 2 connectable NTC temperature probes or door contacts stores all measured temperature values and door contacts and transmits them directly by wireless LAN to the Testo Cloud. You can use the alarm function to receive immediate warnings by e-mail or SMS (optional) when limit values are violated.
FEATURESAutomated door contact and temperature monitoring with connectable probes (optional).
WiFI data logger system with easy installation and operation.
Call up measurement data at any time via Smartphone, tablet or PC.
Limit value violation alarms by e-mail or (optionally) SMS.
WiFi Data Logger: Advantages and Functions
Current measuring values, limit value violations and the remaining battery life can be seen in the data logger's display. The standard batteries (AA) have a lifetime of 12 months and can be replaced at any time by users themselves. The internal data memory of the WiFi data logger has a capacity of 2 x 10,000 readings and the housing is protected according to IP54.
Depending on the range of functions you require, you have a choice between the free Basic and the more extensive Advanced functionality for use of the Testo Cloud, one advanced license must be purchased per logger:
Basic (free) | Advanced | |
Measuring cycle | 15 min. ... 24 h | 1 min. ... 24 h |
Communication cycle | 15 min. ... 24 h | 1 min. ... 24 h |
Data storage | Max. 3 months | Max. 2 years |
Reports | Manual (.pdf/.csv) | Manual (.pdf/.csv) Automatic (.pdf/.csv) |
Number of users per account | 1 | 10 |
Number of WiFi data loggers per account |
Unlimited | Unlimited |
Alarm options | Upper/lower alarm limits | • Upper/lower alarm limits • Alarm delay • Time control of alarms |
System notifications | • Notification of low battery • Radio link interrupted • Power supply interrupted |
• Notification of low battery • Radio link interrupted • Power supply interrupted |
E-mail alarm | Yes | Yes |
SMS alarm | No | • Including 25 SMS per logger and year • Option of purchasing additional SMS packages |
Measurement data export (API interface) | Yes | Yes |
Temperature - NTC | |
---|---|
Measuring range | -50 to +150 °C. |
Accuracy | ±0.3 °C. |
Resolution | 0.1 °C. |
General Technical Data | |
Dimensions | 95 x 75 x 30.5 mm. |
Operating temperature | -30 to +50 °C. |
Protection class | IP65. |
Door contact | Yes. |
Communication rate | Dependent on Cloud licence; Basic: 15 min … 24 h / Advanced: 1 min … 24 h. |
WLAN Connectivity | Signal transmission: wireless; frequency band: 2.4 GHz; supported wireless LAN standards: IEEE 802.11 b/g/n and IEEE 802.1X; Possible encryption methods: without encryption, WEP, WPA, WPA2, WPA2 Enterprise - The data loggers communicate via the standard protocol MQTT and are SNTP time synchronization-capable. |
Measuring rate | Dependent on Cloud licence; Basic: 15 min … 24 h / Advanced: 1 min … 24 h. |
Standards | EN 12830. |
Power supply | 4 x AA AlMn batteries; mains unit optional; for temperatures below -10 °C please use Energizer batteries 0515 0572. |
Memory | 10,000 measurement values / channel. |
Battery life | 12 months (typical value, depending on the wireless LAN infrastructure) at +25 °C, 15-minute measuring cycle and standard communication cycle at -30 °C, 15-minute measuring cycle and standard communication cycle with Energizer batteries 0515 0572. |
Storage temperature | -40 to +70 °C (without batteries). |
Weight | 240 g. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
External NTC Temperature Probes | ||||
Probe with Velcro (NTC) | With Velcro: makes it easy to attach the surface probe to pipes with a pipe diameter of up to 75 mm. Measuring range: -50 to +70°C. |
0613 4611 | ||
Stub Probe | NTC temperature probe with short probe tube (stub probe) for measurement in liquids, pastes and in air. Measuring range: -20 to +70 °C. |
0628 7510 | ||
NTC Temperature Probes | ||||
Surface Measurement Probe | NTC temperature probe with 2 m cable, for long-term measurements it can be affixed using a screw for example. Measuring range: -50 to +80 °C. |
0628 7516 | ||
Temperature Probes | ||||
Connectable Temperature Probe | Compactly connected to the logger: the probe is plugged directly into the logger. Measuring range: -30 to +50 °C. | 0572 2153 | ||
Immersion/ penetration Probes | ||||
Probe with Penetration Tip | NTC probe with exceptionally flat cable (2 m long), which can be pushed through narrow openings, e.g. through slits in doors. For measurement in pastes and semi-solid media and also in liquids and air. Measuring range: -40 to +125 °C. |
0572 1001 | ||
Surface Measurement Probe | NTC probe with exceptionally long 6 m cable, can be installed for long-term measurements. For measurement in liquids, pastes and in air. Measuring range: -35 to +80 °C. |
0610 1725 | ||
Probe with Long Cable | NTC probe with exceptionally long 6 m cable, can be installed for long-term measurements. For measurement in liquids, pastes and in air. Measuring range: -35 to +80 °C. |
0610 1725 | ||
Probe with Aluminium Sleeve | NTC temperature probe with 2.4 m cable, can be installed at the measuring location for long-term measurements. For measurements in liquids, pastes and air. Measuring range: -30 to +90 °C. |
0628 7503 |
COMPONENT |
DESCRIPTION | PART No. | ||
Door Contact Cable | To connect data loggers and standard door contacts. Enables the opening of refrigerator doors to be recorded. | 0572 2152 | ||
Mains Unit | Mains unit for wireless LAN data logger for optional, external power supply of the WiFi data loggers. | 0572 2020 |