- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Testo 440 Lux Kit
Includes: testo 440 air velocity and IAQ measuring instrument, 3 x AA batteries, USB cable and calibration protocol, Lux probe with fixed cable (cable length 1.4 m) and calibration protocol, Basic case for testo 440 and 1 probe.
Kit for measuring the illuminance in workplaces, for example in offices or in production areas.
As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
The lux probe is ideal for determining the illuminance in workplaces. It assesses the illuminance according to the V-lambda curve, which corresponds to the sensitivity of the human eye in daylight. White or warm light LEDs (K< 5,000) can also be measured without any problem.
The 1.4 m cable length means that you can place the probe directly at the measuring location and carry out the measurement from a sufficient distance. So the readings are not affected by your shadow.
The clearly structured measurement menu for long-term measurement enables the measuring instrument to be operated intuitively. Reading trends are reliably recorded thanks to the convenient input of measurement time and measuring cycle.
Intuitive: clearly structured measurement menu for long-term measurement and determination of illuminance according to the V-lambda curve , thus for all common light sources
Precise: standard-compliant accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
Convenient: non-slip probe contact surface for convenient positioning at the measuring location, internal data storage and USB port for data export
As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
The lux probe is ideal for determining the illuminance in workplaces. It assesses the illuminance according to the V-lambda curve, which corresponds to the sensitivity of the human eye in daylight. White or warm light LEDs (K< 5,000) can also be measured without any problem.
The 1.4 m cable length means that you can place the probe directly at the measuring location and carry out the measurement from a sufficient distance. So the readings are not affected by your shadow.
The clearly structured measurement menu for long-term measurement enables the measuring instrument to be operated intuitively. Reading trends are reliably recorded thanks to the convenient input of measurement time and measuring cycle.
Intuitive: clearly structured measurement menu for long-term measurement and determination of illuminance according to the V-lambda curve , thus for all common light sources
Precise: standard-compliant accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
Convenient: non-slip probe contact surface for convenient positioning at the measuring location, internal data storage and USB port for data export
FEATURES
Structured measurement menu for long-term measurements.
Wireless probe, internal data storage and USB port for data export.
Can be extended with a large portfolio of digital probes.
Testo 440 Product Video
Testo 440 Specifications
Temperature NTC | |
Measurement Range | -40 to +150 °C. |
Accuracy | ±0.4 °C (-40 to -25.1 °C) ±0.3 °C (-25 to +74.9 °C) ±0.4 °C (+75 to +99.9 °C) ±0.5 % of mv (Remaining Range). |
Resolution | 0.1°C. |
Temperature - TC Type K (NiCr-Ni) | |
Measurement Range | -200 to +1370 °C. |
Accuracy | ±(0.3 °C + 0.3 % of mv). |
Resolution | 0.1 °C. |
General Specifications | |
Data transmission | Bluetooth®, USB interface. |
Operating Temperature | -20 to +50°C. |
Connectable probes | 1 x digital probe with cable or 1 x Temperature NTC TUC, 1 x digital Bluetooth probe or testo Smart Probe, 1 x Temperature TC Type K. |
Battery Type | 3 AA mignon 1.5 V. |
Battery life | 12 h (typically vane measurement). |
Dimensions | 154 x 65 x 32 mm (testo 440). |
Weight | 250 g. |
Testo 440 warranty | 2 years. |
Lux Probe (digital)
Measuring range | 0 to 100000 Lux. |
Accuracy | DIN EN 13032-1 Appendix B Class C according to DIN 5032-7. |
Resolution | 0.1 Lux (< 10000 ) 1 Lux (> 10000 ). |
Cable length | 1.4 m. |
Operating Temperature | 0 to +50 °C. |
Storage temperature | -20 to +50 °C. |
Dimensions | 110 x 55 x 22 mm. |
Weight | 110 g. |
No customer reviews for the moment.