- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Megger CSU600AT High Current Supply Unit
Includes: Complete with: Cable set GA-05052, Transport case GD-00182 and CSU 600AT User Manual.
The Megger CSU600AT high-current supply unit has two main fields of application. The first is to conduct primary tests on protective relays. A primary test shows whether all parts of the protection system are functioning together properly within the specified time limits under operating conditions. The second field of application involves conducting current tests on low-voltage circuit breakers and overcurrent devices.
It has a built-in timer and an analog ammeter that provide rough current settings quickly and easily. As a result, connection time has been reduced to the bare minimum.
FEATURES
Compact and rugged.
Quick and easy to use.
Broad application range.
Excellent weight/performance ratio.
Current Supply Units CSU600A/AT are used for:
Performance and transformation-ratio testing of current transformers.
Primary testing of relay-type cutouts.
Testing circuit breakers.
Commissioning of substation switchgear.
115 V Mains Voltage | 230 V Mains Voltage | |||
Current | Load time | Minimum Output Voltage | Load time | Minimum Output Voltage |
0 A | Cont. | 6 V | Cont. | 9.5 V. |
75 A | - | - | Cont. | 9.3 V. |
100 A | Cont. | 5.6 V | 1 hr | 9.0 V. |
200 A | 15 mins. | 5.3 V | 5 mins. | 8.5 V. |
300 A | 1.5 mins. | 4.9 V | 2 mins. | 8.0 V. |
400 A | 1 min. | 4.6 V | 1 min. | 7.5 V. |
500 A | 20 s. | 4.2 V | 30 s | 7.0 V. |
600 A | 15 s. | 3.9 V | 20 s | 6.5 V. |
1) Maximum load time from cold state 25°C (77°F). Not valid for repeated tests. |
Measurement section | |||
Output for external ammeter | 600/6 A. | ||
Inaccuracy | ±0.5%. | ||
Timer (only CSU600AT) |
|||
Range | 0-999.999 s. | ||
Resolution | 1 ms. | ||
Inaccuracy | ±0.02% of shown value + 0 to 2 ms. | ||
Maximum cable lengths at 600 A | |||
230 V mains | 2 x 5 m (16 ft), 70 mm² 2 x 5 m (16 ft), 50 mm² 2 x 10 m (33 ft), 70 mm² 2 x 15 m (49 ft), 95 mm². |
||
15 V mains | 2 x 5 m (16 ft), 70 mm². | ||
General Specifications | |||
Specifications are valid at nominal input voltage and an ambient temperature of +25°C, (77°F). Specifications are subject to change without notice. | |||
Operating temperature | 0°C to +50°C (32°F to +122°F). | ||
Storage temperature | -40°C to +70°C (-40°F to +158°F). | ||
Humidity | 5% – 95% RH, non-condensing. | ||
CE-Marking | EMC: 2004/108/EC LVD: 2006/95/EC. |
||
Mains voltage | 15 or 230 V AC, 50 / 60 Hz. | ||
Power consumption (max) | 115 V, 667 VA cont. (interm. 3738 VA) 230 V, 851 VA cont. (interm. 6440 VA). |
||
Protection | Thermal cut-outs and miniature circuit breakers. | ||
Dimensions | Instrument: 356 x 203 x 241 mm (14.0” x 8.0” x 9.5”) Transport case: 610 x 290 x 360 mm (24.0 x 11.4 x 14.2”). |
||
Current cables | 2 x 5 m (16 ft), 50 mm². | ||
Weight | 21.9 kg (48 lbs) 38.3 kg (84.4 lbs) with accessories and carrying case. | ||
Megger CSU600AT warranty | One year. |
No customer reviews for the moment.
Cable set 10 m | 2 x 10 m (33 ft), 70 mm2, Weight: 16.8 kg (37 lbs). | GA-07102 | |
Cable set 15 m | 2 x 15 m (49 ft), 95 mm2, Weight: 29.4 kg (65 lbs). | GA-09152 | |
TM200 | Timer. See TM200 datasheet for more information | BE-29090 |