Megger RCDT330 RCD Tester
Includes: RCDT330 RCD tester, 2 wire test lead with prods with clips, 8 x AA (LR6) batteries (fitted in instrument), Warranty card, Calibration certificate, CD containing user manual, Safety instructions, USB download lead, Download manager CD, Printed quick start guide, Mains plug test lead.
The Megger RCDT330 covers a wider supply voltage range of 50V to 290V than the RCDT310, allowing use with centre-tapped 110V supplies. It incorporates ramp testing testing, for RCD tripping current measurement, and the unique Megger auto sequence test feature, which saves time by allowing the tester to conduct all the RCD tests, and to store the results while the operator stands by the RCD, resetting it as appropriate.
The operating current range of the RCDT330 covers 10mA to 1,000mA devices, and the ability to measure AC supply voltage and frequency. The large liquid crystal display for test results is backlit in this model, making it easier to use in locations with low ambient light levels. Data is stored in non-volatile memory, being retained when the instrument is switched off or batteries are exhausted.
FEATURES
Tests standard, DC and selective RCDs.
Ramp testing.
Auto (Remote) testing.
3 Phase safe.
Enables testing on 110 V centre tapped supplies.
Tough rubber armoured case with built-in cover.
Weatherproof to IP54.
RCD Test Ranges (to EN61557-6) | |
Supply Voltage | RCDT310: 100 V to 280 V (45 Hz to 65 Hz) RCDT320: 50 V to 280 V (45 Hz to 65 Hz) RCDT330: 50 V to 280 V (45 Hz to 65 Hz) Minimum voltage 71 V for 300 mA RCDs, 100 V for 500 mA RCDs and 205 V for 1000 mA RCDs. |
Test Current Accuracy | |
No Trip Test | (1/2I): -8 to -2%. |
Trip Test | (I, 5I): +2% to +8%. |
Trip Time | ±1% ± 1 ms. |
Voltage Measurement | |
AC Range | 0 to 300 V (25 to 450 Hz). |
Accuracy | ±2% ± 2 digits. |
Frequency Measurements (RCDT320/330 Only) | |
Range | 25 to 450 Hz. |
Accuracy | 25 to 199.9 Hz ± 0.1 Hz 200 Hz to 450 Hz ± 1 Hz. |
Fault (Touch) Voltage | |
Displayed Range | 0 to 50 V. |
Error | +5%/+15% ± 0.5 V. |
Programmable RCD Step Increments | |
10 mA to 50 mA | 1 mA steps. |
50 mA to 500 mA | 5 mA steps. |
500 mA to 1000 mA | 10 mA steps. |
Test Result Storage (1000 Results) - RCDT330 Only | |
Job Number | 256 locations. |
Distribution Board Number | 99 locations. |
Circuits | 99 locations. |
Phases | P1, P2, P3. |
Temperature and Humidity | |
Operating Range | -5 to 40°C. |
Operating Humidity | 93% RH at +40°C max. |
Storage Range | -25 to 70°C. |
Maximum Altitude | 2000m. |
Environmental Protection | IP54. |
Safety | |
Rating | IEC 61010-1 CAT III 300 V phase to earth. |
Power Supply | |
Batteries | 8 x 1.5 V cells IEC LR6 type (AA alkaline). |
Rechargeable | 8 x 1.2 V NiCd or NiMH cells. |
Battery Life | 2000 consecutive tests. |
General Specs | |
Weight | 980g. |
Dimensions | 203 x 148 x 78 mm. |
E.M.C | In accordance with IEC61326-1. |
Megger RCDT330 warranty | Three-years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Lead Set | 2-wire test lead with prods and clips. | 1003-132B | ||
Mains Plug | UK Mains Plug test leadset, 3-pin 1 wire (BS1363 plug). | 6231-601 | ||
Case | Blow Moulded Case. MIT/LTW/RCDT. | 1007-167 |