- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Chauvin Arnoux PEL 102 Power Logger
Includes: 4 measurement leads (straight banana / straight banana, 3m long, black), 4 croc clips (black), 3 MA193 mini-AmpFLEX sensors (cable length 3 m), 1 SD card (2 GB), 1 SD-USB adapter, 1 set of inserts (ends of leads and current sensors), 1 mains power cable (1.8 m long - 250 V), 1 USB cable (Type A / Type B - 1 m long), 1 Multifix mounting systems, 1 operating manual (on CD), 1 bag & 1 safety datasheet.
The PEL 102 is a low cost, simple to use, one, two (split phase) and three phase power / energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits.
All vital energy data is easily measured, recorded, and analysed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customisable Reports supplied). The instrument’s design enables it to be installed inside a load center panel (including the current sensors) and still allow the door to close on most panels.
When installed for a long period in a cabinet, PEL100 loggers constantly monitor the active, apparent and reactive power values on the electrical network involved. This means they will instantly detect whenever the subscribed power threshold is exceeded.
With the software for automatically generating and printing reports, balance sheets, graphs or DataView® summaries, users can act quickly on the cause of this over-consumption which will lead to higher bills. Indeed, every time your subscribed power threshold is exceeded, your bill will increase.
ADVANTAGES
0.2 % accuracy class.
Measurement of power indices, PF, THD, hour meter, min/max, etc.
Measurement of all power values.
Measurement from DC up to 400 Hz.
Energy measurement and costing.
Voltage up to 1,000 V.
Communication via Ethernet, Bluetooth and SD card.
Simple to set up without opening the electrical network.
Configuration in record time.
Recording on SD card.
All vital energy data is easily measured, recorded, and analysed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customisable Reports supplied). The instrument’s design enables it to be installed inside a load center panel (including the current sensors) and still allow the door to close on most panels.
When installed for a long period in a cabinet, PEL100 loggers constantly monitor the active, apparent and reactive power values on the electrical network involved. This means they will instantly detect whenever the subscribed power threshold is exceeded.
With the software for automatically generating and printing reports, balance sheets, graphs or DataView® summaries, users can act quickly on the cause of this over-consumption which will lead to higher bills. Indeed, every time your subscribed power threshold is exceeded, your bill will increase.
ADVANTAGES
0.2 % accuracy class.
Measurement of power indices, PF, THD, hour meter, min/max, etc.
Measurement of all power values.
Measurement from DC up to 400 Hz.
Energy measurement and costing.
Voltage up to 1,000 V.
Communication via Ethernet, Bluetooth and SD card.
Simple to set up without opening the electrical network.
Configuration in record time.
Recording on SD card.
Chauvin Arnoux PEL Product Video
Chauvin Arnoux PEL102 Specifications
General Specifications | |||
Display | Without. | ||
Installation types | Single-phase, split-phase, three-phase with or without neutral and many other specific configurations. | ||
Accuracy class | 0.2%. | ||
Electrical Specifications | |||
Number of channels | 3 voltage inputs / 3 current inputs (calculation of neutral current). | ||
Network frequency | DC, 50 Hz, 60 Hz and 400 Hz. | ||
Voltage range | 0 to 1,000 V AC and DC. | ||
Current (depending on sensor) | 5 mA ac to 10 kA ac / 50 mA dc to 1.4 kA dc / ±0.5 %. | ||
Voltage ratio/ Current ratio | Up to 650,000 V / up to 25,000 A. | ||
Calculated Measurements | |||
Power | 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA. | ||
Energy | Up to 4EWh / 4 EVAh / 4 Evarh. | ||
Phase | cos φ, tan Φ, PF. | ||
Harmonics | Up to the 50th order. | ||
Complementary Functions | |||
Phase order | Yes. | ||
Min/max | Yes. | ||
Mounting | Magnet, hook. | ||
Recordings | |||
Sampling / Acquisition rate / Aggregation | 8 samples/period - 1 measurement per second from 1 min to 60 min. | ||
Memory | SD card, 2 GB (SD-HC up to 32 GB). | ||
Communication | Bluetooth (Class 1), Ethernet, USB. | ||
Power supply | 110 V - 250 V (+ 10%, - 15 %) @ 50-60 Hz & 400Hz. | ||
Safety | IEC 61010 CAT IV 600 V and CAT III 1,000 V. | ||
Casing |
IP54, UL (pending). | ||
Mechanical | |||
Dimensions | 256 x 125 x 37 mm without sensor. | ||
Weight | 900 g. | ||
Chauvin PEL102 warranty | 3 year. |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | ||
S/ware |
DataVIEW® software. | P01102095 | ||
Markers | Set of id. rings/inserts. | P01102080 | ||
Clamp | MN93 clamp. | P01120425B | ||
AmpFlex | AmpFlex® A193-450 mm clamp. | P01120526B | ||
Mains |
Mains adapter. | P01102134 | ||
Carry bag |
Bag no. 23. | P01298078 |