- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Fluke 1662 Multifunction Installation Tester
Includes: 6x AA (IEC LR6) cell batteries, C1600 hard carrying case, zero adapter, heavy duty mains cord, STD standard test lead set, padded carrying and waist strap, quick reference guide, TP165X remote control probe and lead set (FTP/UK fused probes, UK only), User’s manual on CD-ROM.
The Fluke 1660 Series Installation Testers are the only installation testers that help prevent damage to connected appliances and also allow users to send test results wirelessly via smartphone directly from the field.
The Fluke 1662 tester verifies the safety of electrical installations in domestic, commercial and industrial applications. It can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364 and all relevant local standards.
Reduce test time up to 40% with Auto Test. Auto Test does 5 required installation tests in one sequence, including selectable Type A, AC & RCD Auto Test, ensuring compliance with local installation regulations. It reduces the number of manual connections, decreases the possibility of making errors and reduces test time up to 40 % from previous Fluke models.
FEATURES
Voltage & frequency.
Wiring polarity checker, detects broken N wires.
Insulation resistance.
Continuity & resistance.
Measure motor windings with continuity test.
Loop & line resistance.
Prospective earth fault current (PEFC/IK).
Prospective short-circuit current (PSC/IK).
RCD switching time.
RCD tripping level (ramp test).
Measures trip time & current for RCD type A & AC in one test.
RCD variable current.
Automatic RCD test sequence.
Phase sequence indicator.
On/Off switchable Auto Start for RCD and Looptest.
Self-test.
Illuminated display.
AC Voltage Measurement | |||
Range | 500 V. | ||
Resolution | 0.1 V. | ||
Accuracy (45 Hz – 66 Hz) | 0.8% + 3. | ||
Input impedance | 360 kΩ. | ||
Overload protection | 660 V rms. | ||
Continuity Testing (RLO) | |||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω. | ||
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω. | ||
Open Circuit Voltage | >4 V. | ||
Insulation Resistance Measurement (RISO) | |||
Test voltages | 50-100-250-500-1000 V. | ||
Accuracy of Test voltage (at rated test current) | +10%, -0%. | ||
Test voltage | 100 V 250 V 500 V 1000 V |
||
Insulation resistance range | 20 MΩ /50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ |
||
Resolution | 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ |
||
Test current | 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ |
||
Loop & Line Impedance (ZI) | |||
Range | 10 Ω / 0.001 Ω / High current mΩ mode. | ||
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω. | ||
Prospective Earth Fault Current, PSC Test | |||
Range | 1000 A / 10 kA (50 kA). | ||
Resolution | 1 A / 0.1 kA. | ||
RCD Testing, RCD Types Tested | |||
RCD Type | A4, AC¹, G², S³ | ||
Notes | ¹Responds to AC ²General, no delay ³Time delay 4Responds to pulsed signal 5Responds to smooth DC signal |
||
Tripping Speed Test (ΔT) | |||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR 10-30-100 mA |
||
Multiplier | x ½, x 1, x 5 | ||
Notes | ¹1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. |
||
General Specifications | |||
Battery size, quantity | Type AA, 6 ea. | ||
Sealing | IP-40. | ||
Dimensions (L x W x H) | 10 x 25 x 12.5 cm. | ||
Weight (incl. batteries) | 1.3 Kg. | ||
Fluke 1662 warranty | 3 years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
C1600 | Hard carrying case for meter and accessories. | 2091049 | ||
TP165X | Remote control probe. | 2107742 | ||
Zero Adapter | Zero adapter for test lead null. | 3261925 | ||
166X-MTC-UK | Fluke 166X Main test cord. | 4601070 | ||
DMS COMP | DMS Complete, Installation and PAT software. | 4718790 |