loading spinner
Fluke MDA-510 Motor Drive Analyser
  • Fluke MDA-510 Motor Drive Analyser
  • Fluke MDA-510 Motor Drive Analyser
  • Fluke MDA-510 Motor Drive Analyser

Fluke MDA-510 Motor Drive Analyser

Fluke authorised distributor and calibration house.

Includes: 1x BP 291 li-ion battery pack, 1x BC190 charger/power adapter, 3x VPS 100:1 high voltage probes with alligator clips, 1x VPS410-II-R 10:1 500MHz voltage probe, 1x i400s ac current clamp, 1x C1740 carrying case, 1x 2 GB USB drive with manuals and FlukeView™ 2 software.

mda-510
£5,067.00
Tax excluded
Quantity
  • done HTTPS SECURE: Our pages are encrypted and protected from cyber-attack.
  • done COMPLIANT: Payment Card Industry Data Security Standard (PCI DSS) Compliant.
  • done PROTECTED: by TLS (SSL) - all data/information is secure from interception.
Simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results. The MDA-510 and MDA-550 are the ideal portable motor-drive analysis test tools and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.

The MDA-550/MDA-510 Motor Drive Analyzer is an extension of the ScopeMeter® Test Tool 190 Series II with additional functionality and accessories that test inverter type motor drives. Inverter type motor drives are known as variable frequency drives or variable speed drives and use pulse width modulation to control ac motor speed and torque. The test tool supports motor drives with signal levels up to 1000 V to ground.

KEY FEATURES

Key motor drive parameters: Includes measurement of voltage, current, dc link voltage level and ac ripple, voltage and current unbalance, harmonics (MDA-550), and voltage modulation.

Extended harmonics: Identifies the effects of low and high order harmonics on the electrical power system.

Guided measurements: Guidance for motor drive input, dc bus, drive output, motor input, and shaft measurements (MDA-550).

Simplified measurement setup: Graphically shows how to connect and then automatically triggers according to the selected test procedure.

Reports: Use for troubleshooting and collaborative work with others.

Additional electrical parameters: Full 500 MHz oscilloscope capability is available for the complete range of electrical and electronic measurement on industrial systems.

The MDA-500 Series is designed to help you quickly and easily test and troubleshoot typical problems on three-phase and single-phase inverter type motor-drive systems. The on-screen information, and step-by-step setup guidance make it easy to configure the analyzer and get the drive measurements you need to make better maintenance decisions, fast. From power input to the installed motor, the MDA-500 provides the measurement capability for the fastest motor-drive troubleshooting.

Fluke MDA-550 Series Product Video

Fluke MDA-510 & MDA-550 Specifications
Measurement Function
DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe 1000 V.
Maximum resolution with 10:1 or 100:1 probe 1 mV.
Full scale reading 999 counts.
Accuracy at 4 s to 10 us/div ±(3 % + 6 counts).
AC voltage (V ac)
Maximum voltage with 10:1 or 100:1 probe 1000 V.
Maximum resolution with 10:1 or 100:1 probe 1 mV.
Full scale reading 999 counts.
50 Hz ±(3 % + 10 counts) - 0.6 %.
60 Hz ±(3 % + 10 counts) - 0.4 %.
60 Hz to 20 kHz ±(4 % + 15 counts).
20 kHz to 1 MHz ±(6 % + 20 counts).
1 MHz to 25 MHz ±(10 % + 20 counts).
True-rms voltage (V ac+dc)
Maximum voltage with 10:1 or 100:1 probe 1000 V.
Maximum resolution with 10:1 or 100:1 probe 1 mV.
Full scale reading 1100 counts.
DC to 60 Hz ±(3 % + 10 counts).
60 Hz to 20 kHz ±(4 % + 15 counts).
20 kHz to 1 MHz ±(6 % + 20 counts).
1 MHz to 25 MHz ±(10 % + 20 counts).
PWM voltage (V pwm)
Purpose To measure on pulse width modulated signals, like motor drive inverter outputs.
Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency.
Accuracy As Vac+dc for sinewave signals.
Peak voltage (V peak)
Modes Max peak, min peak, or pk-to-pk.
Maximum voltage with 10:1 or 100:1 probe 1000 V.
Maximum resolution with 10:1 or 100:1 probe 10 mV.
Accuracy
Max peak, min peak ±0.2 division.
Pk-to-pk ±0.4 division.
Full scale reading 800 counts.
General Specification
Current (AMP) with current clamp
Ranges Same as V ac, Vac+dc or V peak.
Scale Factors 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A.
Accuracy Same as Vac, Vac+dc or V peak (add current clamp accuracy).
Frequency (Hz)
Range 1.000 Hz to 500 MHz.
Full scale reading 999 counts.
Accuracy ±(0.5 % + 2 counts).
Voltage/Hertz ratio (V/Hz)
Purpose To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives.
Accuracy % Vrms + % Hz.
Voltage unbalance drive input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages.
Accuracy Indicative percentage based on Vac+dc values.
Voltage unbalance drive output and motor input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages.
Accuracy Indicative percentage based on V PWM values.
Current unbalance drive input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values.
Accuracy Indicative percentage based on A ac+dc values.
Current unbalance drive output and motor input
Purpose To show the highest percentage difference of one of the phase vs average of the 3 AC current values.
Accuracy Indicative percentage based on A ac values.
Rise and fall time
Readings Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot.
Accuracy As oscilloscope accuracy.
Harmonics and spectrum
Harmonics DC to 51st.
Spectrum ranges 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation).
Shaft voltage
Events / second Indicative percentage based on rise and fall time (Impulse discharges) measurements.
Report data capture
Number of screens Typical 50 screens can be saved in reports (depends on compression ratio).
Transfer to PC Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool.
Probe settings
Voltage probe 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1.
Current clamp 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A.
Shaft voltage probe 1:1, 10:1, 100:1.

Download

Fluke MDA-500 Datasheet

PDF Specifications of the Fluke MDA-510 & the Fluke MDA-550 Motor Drive Analysers.

Download (922.51k)

No customer reviews for the moment.

Write your review

Fluke MDA-510 Motor Drive Analyser
COMPONENT
DESCRIPTION PART No.
SB-500 Replacement Brush Set for Models MDA510 and MDA550. FLU-SB-500
SVS-500 Shaft Voltage Set. Shaft Voltage Set. Set of 3x brushes, probe holder, two-piece extension rod and magnetic base. SVS-500
i400s AC current clamp (400 A). 2277202
BP291 4800 mAh High Capacity Li-Ion Battery. 3894688
BC190 Line Voltage Adapter / Battery Charger. 1282244
HH290 Hanging hook for meter. 3894844
C1740 Soft case for meter. 4116762

8 other products in the same category:

ALL-TEST Pro Motor Genie

Call For Price
(0)
Call For Price

ALL-TEST Pro 5 Motor Circuit Analyser

(0)
Call For Price

ALL-TEST Pro 33 IND Software

Call For Price
(0)
Call For Price
All-Test PRO On-Line II All-Test PRO On-Line II
  • New

All-Test PRO On-Line II

Call For Price
(0)
Call For Price
ALL-TEST Pro MD III Assembly ALL-TEST Pro MD III Assembly
  • New

ALL-TEST Pro MD III Assembly

Call For Price
(0)
Call For Price

ALL-TEST Pro 33 IND Motor Tester

Call For Price
(0)
Call For Price
arrow_upward