Martindale HPAT500/2 PAT Tester
Includes: HPAT 500/2, Earth Bond Probe with Croc Clip, Calibration Certificate, 6 x 1800mAh NiMH Rechargeable Batteries, Mains Battery Charging Adaptor, 240V Extension Lead Adaptor, Soft Carry Case with Strap, Printed Instruction Manual.
The Martindale HPAT500/2 is a battery powered, hand held PAT tester with simple one-button test selection. It is ideal for use where there is no convenient power socket and provides a time saving solution when adopting a mobile approach to PAT testing.
Unlike similar PAT testers, the HPAT500/2 has a unique feature to counteract issues with testing appliances with long leads, or long extension leads, caused by the extra resistance added as a result of the lead length.
The HPAT500/2 has a new high contrast backlit display.
FEATURES
Simple One Button Operation.
Automatic Class I, Class II & power lead tests.
Pass / Fail Tester with Result.
Measured values displayed.
Selectable 250V insulation test for surge protected equipment.
I.T. safe 200mA DC earth bond test with two pass levels.
Rechargeable Batteries & Charger Included.
Low Current Bond Test for Sensitive IT Equipment.
Tests both 240V and 110V appliances.
Mains rechargeable with in-car option.
Ideal for Low Volume Testing.
Unlike similar PAT testers, the HPAT500/2 has a unique feature to counteract issues with testing appliances with long leads, or long extension leads, caused by the extra resistance added as a result of the lead length.
The HPAT500/2 has a new high contrast backlit display.
FEATURES
Simple One Button Operation.
Automatic Class I, Class II & power lead tests.
Pass / Fail Tester with Result.
Measured values displayed.
Selectable 250V insulation test for surge protected equipment.
I.T. safe 200mA DC earth bond test with two pass levels.
Rechargeable Batteries & Charger Included.
Low Current Bond Test for Sensitive IT Equipment.
Tests both 240V and 110V appliances.
Mains rechargeable with in-car option.
Ideal for Low Volume Testing.
Martindale HPAT500 Product Video
Martindale HPAT Comparison Chart
HPAT400 | HPAT500/2 | HPAT600/2 | |
---|---|---|---|
Class I /II Test | ✔ | ✔ | ✔ |
Lead Test | ✔ | ✔ | ✔ |
Pass/Fail Indication | ✔ | ✔ | ✔ |
Test Values Displayed | - | ✔ | ✔ |
Selectable Limits | - | - | ✔ |
Test Mode | Auto | Auto | Auto/Manual |
Run Test | - | - | Simulated |
Earth Continuity Test Current | 200 mA | 200 mA | 200m A |
Insulation Test Voltage | 500 V | 250/500 V | 250/500 V |
110V Appliances | With accessory | With accessory | With accessory |
Memory | - | - | 200 results for on-screen recall |
Supply | Alkaline batteries | Rechargeable | Rechargeable |
Martindale HPAT500/2 Specifications
Earth Continuity | ||
Test Voltage | 4 V DC (into open circuit). | |
Test Current | 200 mA DC (into short circuit). | |
Range | 0 to 19.99 Ω. | |
Resolution | 0.01 Ω. | |
Accuracy | ± (5% of reading + 2 digits). | |
Fixed Pass Limits | ||
Lead | ≤ 0.10 Ω = PASS ≤ 0.20 Ω = NOTE x.xx PASS. |
|
Class I | Class I ≤ 0.10 Ω = PASS ≤ 0.20 Ω = NOTE x.xx PASS. |
|
Insulation | ||
Fixed Voltage | >500 V DC at 1 mA (< 600 V DC into open circuit). | |
Test Current | Test current: 1.5 mA (into short circuit). | |
Ranges | 2.00 MΩ, 20.0 MΩ, 200 MΩ. | |
Resolution | 0.01 MΩ. | |
Accuracy | <100 MΩ ± (5% reading + 2 digits) >100 MΩ ± (10% reading + 2 digits). |
|
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ. |
|
Fuse Checks | ||
Test Voltage | 4V DC (into open circuit). | |
Test Current | 200mA DC (into short circuit). | |
Pass Level | >2mA. | |
General | ||
Overload Protection | 300 V AC/DC. | |
Protection Class | IP20. | |
Safety | Complies to BS EN 61010-1: 2001. | |
Temperature Range | -10 to 40°C, non-condensing. | |
Batteries | 6 x 1.2 V AA NiMH rechargeable batteries 1800mAh, or greater. |
|
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
|
Auto Shut Down | After 10 minutes of inactivity, or when battery low. | |
Battery Charger Input | 230 V 50 Hz. | |
Battery Charger Output | 12 V DC at 300mA, 5.5 jack x 2.5 bore centre positive. |
|
Dimensions | 90 x 210 x 54 mm. | |
Weight | Approx 700g (including batteries & leads). |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Earth Bond Lead | Heavy duty earth bond lead with single 4mm banana plug connection, compatible with the Martindale HPAT500 & HPAT600. | MARTL68 | ||
TL151 | 4 pin, 16A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. | MARTL151 | ||
TL152 | 5 pin, 16A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. | MARTL152 | ||
TL153 | 4 pin, 32A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. | MARTL153 | ||
TL154 | 5 pin, 32A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. | MARTL154 | ||
EX331 | 110V Extension Lead Adaptor, use with PATs that have the IEC lead test built in to test 110V extension leads. | MAREX331 | ||
PAT Register Book | This handy A5 register allows you to keep manual records of PAT testing results for up to 315 appliances to ensure your system is fully compliant. | MARPATREG |
5 other products in the same category: