The GE Druck UPS-II loop calibrator (Druck UPS-2) is an advanced handheld process calibrator tool. It can power (24 VDC) and read 2-wire transmitters to perform field calibrations. Output currents are adjustable to a resolution of 10 microamps in both source and transmitter simulation. The calibrator can source or simulate fixed calibration currents to test or calibrate receivers and to stroke valves. Different current levels are available from the menu.

Output currents can be changed manually or automatically. The time between steps is 10 seconds in the auto-stepping mode. In the valve mode, auto-stepping will be: 3.8, 4, 4.2 or 19, 20, 21 mA. The UPSII calibrator can also source or simulate with high resolution a continuous up/down cycle between 4 and 20 mA or 0 and 20 mA. The travel time between limits is 60 seconds.

FEATURES

Sources and reads milliamps.
Powers and reads 2-wire transmitters.
Reads and simulates DP transmitters in % of flow.
Auto-ramp cycling for endurance tests.
Auto-stepping for hands-free calibration.
Fixed calibration currents.
Fixed currents for valve stroking.

Fixed Steps

The calibrator can source or simulate fixed calibration currents to test or calibrate receivers and to stroke valves. Different current levels are available from the menu.

4 to 20 mA linear 4, 8, 12, 16, 20 mA.
0 to 20 mA linear 0, 5, 10, 15, 20 mA.
4 to 20 mA sq.rt (flow) 4, 5, 8, 13, 20 mA.
0 to 20 mA sq.rt (flow) 0, 1.25, 5, 11.25, 20 mA.
4 to 20 mA 3.8, 4, 4.2, 12, 19, 20, 21 mA.

Output currents can be changed manually or automatically. The time between steps is 10 seconds in the auto-stepping mode. In the valve mode, auto-stepping will be: 3.8, 4, 4.2 or 19, 20, 21 mA.

Ramping

The calibrator can source or simulate with high resolution a continuous up/down cycle between 4 and 20 mA or 0 and 20 mA. The travel time between limits is 60 seconds.

Reading in Percentage

The calibrator can display readings in percentage of a 4 to 20 mA or 0 to 20 mA span and can also read or simulate dP-transmitters directly in percentage of flow.

Druck UPS II Specifications
Output Range 0 to 21.00 mA.
Input Range 0 to 21.00 mA.
Accuracy 0.05% of range.
Resolution 10 microamps.
Temperature Effect 0.0015% /°F (0.003% /°C).
Internal Loop-Power 24 VDC stabilised.
External Loop-Power 56 VDC maximum.
Measurement Input 12 Ω including fuse.
Drive Capability 900 Ω.
Operating Temperature 15°F to 120°F (-10°C to 50°C).
Batteries 4x 1.5V AA Batteries.
Battery Life Sources 12 mA: 13 hours
Measures: 64 hours.
Low Battery Flashes “lobat”.
Housing High impact ABS.
Dimensions 3 in x 5 in x 0.83 in (77 mm x 124 mm x 21 mm).
Weight 9 oz (285 g) including batteries.
Druck UPS-II warranty One year.

Download

Druck UPSII Datasheet

PDF Specifications of the Druck UPSII Loop Calibrator.

Download (483.96k)

No customer reviews for the moment.

Write your review

Druck UPS-II Loop Calibrator
COMPONENT
DESCRIPTION PART No.
Line adaptor 230V UK PLG line adaptor. UNO-13600-1
Line adaptor Line Adapt/Charger (230V, 50Hz) EU. UNO-13600-2
Line adaptor Line Adapt/Charger (115V, 50Hz) USA. UNO-13600-3

16 other products in the same category:

arrow_upward