Fluke 707Ex IS Loop Calibrator
Includes: Alligator test clips, Fluke 707 Ex Instruction manual (on CD-ROM), Protective holster with Flex-Stand, Safety designed test leads, NIST- traceable calibration report and data.
The Fluke 707Ex mA Calibrator is a compact and easy to operate sourcing and measuring tool. The Calibrator tests current loops of 0-20 mA or 4-20 mA and measures dc voltage to 28V. The Fluke707Ex is ideal for use in confined and restricted spaces within Ex-hazardous areas according to IEC/CENELEC and Factory Mutual and is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.
FEATURES
Large display and simple, quick-click push rotary button for easy one-handed operation.
Simultaneous mA and % readout for quick, easy, interpretation of readings.
mA accuracy of 0.015%, superior to other loop calibrators.
1 µA resolution for mA source, simulate and measure.
Push button with 25% steps for fast, easy linearity checks.
0-100% "span check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Measures Vdc to 28 V.
Single 9 V battery that is easily changed.
0-20 mA or 4-20 mA default start up modes.
Innovative output adjustment dial with 1 µA and 100 µA resolution.
HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators.
Features | |||
Current Measurement | Range: 0 to 24 mA Resolution: 0.001 mA Accuracy: 0.015% Rdg + 2 LSD. |
||
Current Sourcing | Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.015% Rdg + 2 LSD Drive Capability: 700 Ω at 20 mA. |
||
Current Simulation | Range: 0 to 20 mA or 4 to 20 mA Accuracy: 0.015% Rdg + 2 LSD. |
||
Loop power | While measuring mA, 24 V. | ||
Environmental Specifications | |||
Operating Temperature | CSA C22.2 No. 1010.1:1992. | ||
Storage Temperature | -40ºC to 60ºC. | ||
Safety Specifications | |||
Safety | CSA C22.2 No. 1010.1:1992. | ||
EMC | EN50082-1:1992 and EN55022:1994 Class B. | ||
Maximum voltage | 30 V. | ||
ATEX certification | Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X. | ||
CE certification | EN61010-1 and EN61326. | ||
General Specifications | |||
Display current and % of span | |||
Auto step, auto ramp | |||
Span Check |
|||
Batteries | One 9V battery Alkaline. | ||
Shock & Vibration | per MIL-T-28800 for a Class 2 Instrument. | ||
Dimensions | 152 x 70 x 41 mm. | ||
Weight | 224 g (350 g including holster). | ||
Fluke 707 Ex warranty | 3 year. |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | ||
AC220 | SureGrip™ Alligator Clip Set. | 1610103 | ||
AC280 | SureGrip™ Hook Clips. | 1610115 | ||
AC283 | SureGrip™ Pincer Clips. | 1610144 | ||
AC285 | SureGrip™ Alligator Clip Set. | 1610159 | ||
C12A | Soft Meter Case. | 930529 | ||
TL220-1 | SureGrip™ Industrial Test Lead Set includes: AC220 SureGrip™ Alligator Clip Set TP220 SureGrip™ Industrial Test Probe Set TL224 SureGrip™ Silicone Test Lead Set (straight to right) |
3971178 | ||
TL223-1 | Electrical Test Lead Set. | 3971184 | ||
TL71-1 | Premium Test Lead Set. | 3971207 | ||
TL75-1 | Hard Point™ Test Lead Set. | 3971218 |