loading spinner
Time 1048
  • Time 1048
  • Time 1048
  • Time 1048
  • Time 1048

Time 1048 Voltage/Current/Loop Calibrator

Time Authorised distributor.

Includes: Leatherette carry case, 9V PP3 battery (installed), and user manual.

1048
£580.00
£696 Inc. VAT

The Time 1048 is a portable instrument that operates as a current and voltage source and a multi-purpose loop calibrator. High performance and simple operation make it suitable for R&D, service, process control engineers, and calibration technicians. As a versatile handheld calibrator, the source and measure capabilities with 0.02 % accuracy mean the 1048 is a compact solution for most simulation and test applications.

Common use of the 1048 is to simulate a transducer or measure the current flow in a transducer loop. As a process calibrator it can be used to check a 4 to 20 mA system in either source or measure modes of operation. The 24 V compliance voltage powering the loop when current source mode is selected.

In source mode the Time 1048 can test and calibrate meters, thermocouple indicators, data loggers. It can also be used for signal injection, semiconductor characterisation, or as a backing off source. In measure mode it can operate as a multimeter, accurately checking DC voltages and currents over 3 ranges.

FEATURES

Source/measure voltage and current.
3 source ranges: 0 to 22 mA & 0 to 22 V.
3 measure ranges: 0 to 70 mA & 0 to 50 V.
Accuracy 0.02 %.
Transmitter simulator/sink loop control.
Output steps and ramps.
Fine adjustment.
20 hours typical battery life.
Optional mains power supply.

Time 1048 Voltage/Current/Loop Calibrator Specifications
Voltage Source
Range Resolution Accuracy Output Current Temp Coefficient
0 to 220 mV 10 μV, 100 μV above 0.2 V 0.05 % of full scale 20 mA ± 6 ppm/°C
0 to 2.2 V 100 μV, 1 mV above 2 V 0.02 % of full scale 20 mA ± 6 ppm/°C
0 to 22 V 1 mV, 10 mV above 20 V 0.02 % of full scale 20 mA ± 6 ppm/°C
Voltage Measure
Range Resolution Accuracy Measure Load Temp Coefficient
0 to 220 mV 10 μV, 100 μV above 0.2 V 0.05 % of fs ± 1 digit 1 MΩ ± 3 ppm/°C
0 to 2.2 V 100 μV, 1 mV above 2 V 0.02 % of fs ± 1 digit 1 MΩ ± 3 ppm/°C
0 to 22 V 1 mV, 10 mV above 20 V 0.02 % of fs ± 1 digit 10 MΩ ± 3 ppm/°C
Current Source
Range Resolution Accuracy Output Voltage Temp Coefficient
0 to 220 μA 10 nA, 0.1 μA above 200 mA 0.05 % of full scale 24 V max ± 12 ppm/°C
0 to 2.2 mA 0.1 μA, 1 μA above 2 mA 0.02 % of full scale 24 V max ± 12 ppm/°C
0 to 22 mA 1 μA, 10 μA above 20 mA 0.02 % of full scale 24 V max ± 12 ppm/°C
Current Measure
Range Resolution Accuracy Measure Load Temp Coefficient
0 to 220 μA 10 nA, 0.1 μA above 200 mA 0.05 % of fs ± 1 digit 1 kΩ ± 8 ppm/°C
0 to 2.2 mA 0.1 μA, 1 μA above 2 mA 0.02 % of fs ± 1 digit 110 Ω ± 8 ppm/°C
0 to 22 mA 1 μA, 10 μA above 20 mA 0.02 % of fs ± 1 digit 16 Ω ± 8 ppm/°C
Sink (TX Sim) 2 wire transmitter simulation: External excitation voltage, 3 V min, 50 V max. The current sink levels are adjustable, with accuracies as in the 3 source ranges shown above. Note: Accuracies in all measure modes are +/-1 digit.
Output Steps 5 fixed 4 mA steps for current output 4, 8, 12, 16 & 20 mA.
11 fixed 1 V steps for voltage output 0,1,2...10 V.
21 fixed steps 1 V/1 mA for V & I output 0,1,2...20.
Stepping can be done manually or automatically (Autostep). Stepping speed is adjustable (1-9 sec/step).
Dwell time (top and bottom) is one step period. In step mode the accuracy is limited to 0.05 % of span +/- 1 digit.
Output Ramp Current Ramp 4 to 20, or 0 to 20 on all ranges.
Voltage Ramp 0 to 10, or 0 to 20 on all ranges.
Ramp time 7 seconds. Dwell (top/bottom) 5 seconds. Manual restart. Ramp operation is also available in Sink (TX SIM).
Output Adjustment A ten turn potentiometer for quick setting, with fine adjust using up/down increment buttons.
Connections Made by 4 mm connectors or clamped using the wire compression feature.
General Specifications
Operating Temperature -10 to 50 °C.
Storage Temperature -30 to 70 °C.
Power PP3 size, 9 V battery (supplied).
Battery life Approximately 20 hours life depending on the current sourced. Optional 12 V power supply can be plugged into the 2.5 mm socket on the top of the unit.
Dimensions HH 142 x W 78 x D 50 mm.
Weight 0.30 kg.

Download

Time 1048 Datasheet

PDF Specifications of the Time 1048 Voltage/Current/Loop Calibrator.

Download (665.44k)