loading spinner
Megger LT300 High Current Loop Tester
  • Megger LT300 High Current Loop Tester
  • Megger LT300 High Current Loop Tester
  • Megger LT300 High Current Loop Tester

Megger LT300 High Current Loop Tester

Megger approved distributor and service centre.

Includes: Megger LT300 Earth Loop Tester, Fused Leads & Clips, Hard Carrying Case.

LT300-EN-FS
Megger
£489.00
£586.8 Inc. VAT

This version of the Megger LT300 Earth Loop Tester ships as standard with a set of fused leads and clips. There are also two other models of this tester available that ship with a mains plug and non-fused leads.

The LT300 offers high current loop testing over a wide range of frequencies and supply voltages with simple, fast, two wire operation. It has a large clear display that aids visibility in poor conditions. The high current loop test provides fast accurate and stable results with a resolution to 0.01Ω on the 20Ω range.

The instrument is housed in a rubber armoured case with a built-in cover to protect the display when not in use. The IP54 weatherproof rating provides excellent protection in adverse conditions.

FEATURES:

CAT IV 300V applications.
High current loop tester.
Portable design made for use out in the field.
Single and 3 phase testing.
16 Hz to 400 Hz operation.
Two wire lead set or mains plug leads.
Tough armoured case.
Built-in cover.

Megger LT300 Specifications
Voltage Measurement Range 0 V to 550 V (400 V @ 16 Hz).
Voltage Accuracy ±5% ± 2 V.
Loop Test Operating Frequencies  16 Hz: 15 Hz to 18 Hz, 29 Hz to 337 Hz
50/60 Hz: 40 Hz to 70 Hz, 125 Hz, 100 Hz to 142 Hz
400 Hz: 260 Hz to 498 Hz.
Test Currents 550 V: 20 Ω - 27 A, 200 Ω - 2.7 A
230 V: 12 Ω - 12 A, 200 Ω - 1.2 A
115 V: 20 Ω - 6 A, 200 Ω - 0.6 A
50 V: 20 Ω - 3 A, 200 Ω - 0.3 A.
Loop Test Accuracy 0 to 19.99 Ω (20 Ω range) - ±5% ±0.03 Ω
0 to 199.9 Ω (200 Ω range) - ±5% ± 0.5 Ω.
Operating Temperature -10 to 60°C.
Storage Temperature -25 to 70°C.
Humidity 90% RH @ 40°C.
Maximum Altitude 2000m.
Dust and Water IP54.
Battery 8 x AA (LR6) Alkaline or NiMH Rechargable Cells.
Safety Meets the requirements of IEC61010-1 300V CAT IV
Phase to Earth or 550V Phase to Phase (400V@16Hz) .
EN61557 Complies with the following parts of EN61577:
Electrical Safety in Low Voltage Systems up to 1000V AC and 1500V DC, Equipment for Testing, Measuring or Monitoring of Protective Measures:
Part 1 - General Requirements
Part 3 - Loop Resistance.
EMC In accordance with IEC61326-1.
Weight 980g (2.6lb).
Dimensions 203 x 148 x 78 mm (8 x 5.8 x 3in).

Download

Megger LT300 Datasheet

PDF Specifications of the Megger LT300 High Current Loop Tester.

Download (291.46k)

No customer reviews for the moment.

Write your review

Megger LT300 High Current Loop Tester

8 other products in the same category: