Megger LT300 High Current Loop Tester
Includes: Megger LT300 Earth Loop Tester, Fused Leads & Clips, Hard Carrying Case.
This version of the Megger LT300 Earth Loop Tester ships as standard with a set of fused leads and clips. There are also two other models of this tester available that ship with a mains plug and non-fused leads.
The LT300 offers high current loop testing over a wide range of frequencies and supply voltages with simple, fast, two wire operation. It has a large clear display that aids visibility in poor conditions. The high current loop test provides fast accurate and stable results with a resolution to 0.01Ω on the 20Ω range.
The instrument is housed in a rubber armoured case with a built-in cover to protect the display when not in use. The IP54 weatherproof rating provides excellent protection in adverse conditions.
FEATURES:
CAT IV 300V applications.
High current loop tester.
Portable design made for use out in the field.
Single and 3 phase testing.
16 Hz to 400 Hz operation.
Two wire lead set or mains plug leads.
Tough armoured case.
Built-in cover.
Voltage Measurement Range | 0 V to 550 V (400 V @ 16 Hz). |
Voltage Accuracy | ±5% ± 2 V. |
Loop Test Operating Frequencies | 16 Hz: 15 Hz to 18 Hz, 29 Hz to 337 Hz 50/60 Hz: 40 Hz to 70 Hz, 125 Hz, 100 Hz to 142 Hz 400 Hz: 260 Hz to 498 Hz. |
Test Currents | 550 V: 20 Ω - 27 A, 200 Ω - 2.7 A 230 V: 12 Ω - 12 A, 200 Ω - 1.2 A 115 V: 20 Ω - 6 A, 200 Ω - 0.6 A 50 V: 20 Ω - 3 A, 200 Ω - 0.3 A. |
Loop Test Accuracy | 0 to 19.99 Ω (20 Ω range) - ±5% ±0.03 Ω 0 to 199.9 Ω (200 Ω range) - ±5% ± 0.5 Ω. |
Operating Temperature | -10 to 60°C. |
Storage Temperature | -25 to 70°C. |
Humidity | 90% RH @ 40°C. |
Maximum Altitude | 2000m. |
Dust and Water | IP54. |
Battery | 8 x AA (LR6) Alkaline or NiMH Rechargable Cells. |
Safety | Meets the requirements of IEC61010-1 300V CAT IV Phase to Earth or 550V Phase to Phase (400V@16Hz) . |
EN61557 | Complies with the following parts of EN61577: Electrical Safety in Low Voltage Systems up to 1000V AC and 1500V DC, Equipment for Testing, Measuring or Monitoring of Protective Measures: Part 1 - General Requirements Part 3 - Loop Resistance. |
EMC | In accordance with IEC61326-1. |
Weight | 980g (2.6lb). |
Dimensions | 203 x 148 x 78 mm (8 x 5.8 x 3in). |