GMI GT Series Multi-functional Gas Detector
Includes: GT Instrument, Dust Filter - Box of 30, User Handbook, Quick Operating Instructions, Calibration Certificate, Configuration Report, Declaration of Conformity.
Designed for the gas industry, the GT Series are multi-application instruments, satisfying all the needs of service technicians within a single unit. With 7 modes of operation, the GT Series is the most versatile instrument available for working with gas.
The GT Series is suitable for the following operations:
Leak test.
Confined space entry.
Barhole testing.
Carbon monoxide.
Purge.
Sniffer.
Pressure leak tightness.
FEATURES
PPM, LEL and Volume Methane flammable gas ranges for leak detection.
Manual and automatic datalogging.
Loud audible and high visual ‘ticker’ (Geiger) on ppm range.
Integral flashlight.
Diversity to suit various applications.
Alkaline or rechargeable battery options.
Charging via simple power cable or docking station.
Rugged polycarbonate case, sealed to IP54.
GAS | RANGE | INCREMENTS | SENSOR TYPE |
O2 | 0 - 25% | 0.1% | Electrochemical |
CO | 0 - 2000 ppm | 1 ppm | Electrochemical |
H2S | 0 - 100 ppm | 1 ppm | Electrochemical |
Dual Tox (CO/H2S) | 0 - 2000 ppm/0-100 ppm | 1 ppm | Electrochemical |
CH4 | 0 - 10,000 ppm | 1 ppm | Semiconductor |
CH4 | 0 - 100% LEL | 1% | Catalytic Bead |
CH4 | 0 - 100% Volume | 1% | Thermal Conductivity Sensor |
Water Gauge | 0-60in. H2O or 0 to 150 mBar |
0.1in. 1 mBar |
Differential Pressure Transducer |
Display | LCD with back light. | ||
Alarms | High visibility LEDs on both sides of instrument 85 db audible alarm All alarms user programmable via password protected menu. |
||
Sampling | Integral pump with pressure sensor for flow fail detection. Sample path is protected by a hydrophobic filter. Respone Time T90 < 30 seconds. |
||
Humidity | 0 - 95% non condensing. | ||
Battery | 3 ‘C’ type batteries – LR14 alkaline or rechargeable. | ||
Battery Life | 8 hours continuous alkaline or rechargeable. | ||
Construction | High impact polycarbonate ABS blend. | ||
Rating | IP65 (Dust tight and water resistant). | ||
Approvals | UL 913 Class I, Div 1, Groups C, D CSA Class I, Groups C, D C22.2 No. 152 SIRA05 ATEX II 2G EEx iad IIB T3 IECEx Ex iad IIB T3. |
||
Dimensions | 290 x 95 x 43 mm / 11.4 x 3.7 x 1.7” (Excl. Probe). | ||
Weight | 0.78 kg / 1.7 lbs (Incl. Probe and Batteries). | ||
GMI GT Series warranty | Two years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Case | Carrying Case. | 67108 | ||
Probe | 35cm Solid End Probe. | 12480 | ||
Probe | 80cm Solid End (Barhole) Probe. | 12393 | ||
Probe | Stainless Steel (Flue) Probe (use with 67142 & 67148). | 67185 | ||
Filter Ass. | Chemical Filter Assembly. | 67142 | ||
Charcoal Granules | Bottle of charcoal granules. | 67148 | ||
Charcoal Filter | Charcoal Filter. | 13936 | ||
Rubber Boot | Rubber Boot. | 67120 | ||
Std. Charger | Standard Instrument Charger (Universal Plug). | 67134 | ||
Vehicle Charger | 12v / 24v Vehicle Instrument charger. | 66206GT | ||
Probe Assy. | Filtered Flue Probe assy. | 67179 | ||
Charging Station | Charging Station (including Power Supply). | 67101 | ||
Power Supply | Power Supply - Universal (for charging station or Auto Cal Station). | 12444 |