Includes: Fluke 9133 calibrator, report of calibration, power cord, user's guide, serial cable, target cover, 9930 software.

1658231
£5886.00
£7063.2 Inc. VAT

The Fluke Model 9133 is small enough to use in the field, and accurate enough to use in the lab. Calibrations may be done over a range of -30°C to150°C (-22°F to 302°F). Temperature display and setability resolution of the 9133 is 0.1 degrees. With a conveniently located dry gas fitting on the front bezel, ice build up on the target can be avoided. At the upper end of its range, the Fluke 9133 provides stable temperatures to 160°C (320°F).

The LED front panel continuously shows the current temperature. The temperature may be easily set with the control buttons to any desired temperature within the specified range. The instrument’s multiple fault protection devices insure user and instrument safety and protection.

The Fluke 9133 calibrator was designed for portability, low cost, and ease of operation. Through proper use, the instrument will provide continued accurate calibration of temperature sensors and devices.

FEATURES

Rapid heating and cooling.
Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F).
Large 57 mm (2.25 in) blackbody target.
Temperature scan rate control.
Eight set-point memory.
Adjustable readout in °C or °F.
RTD reference well for contact temperature measurement.
RS-232 interface capability.
Small, compact design in a blackbody calibrator.

Fluke 9133 Specifications
Temperature Range –30 °C to 150 °C at 23 °C ambient (–22 °F to 302 °F at 73 °F ambient).
Accuracy ± 0.4 °C (± 0.72 °F).
Stability ± 0.1 °C (± 0.18 °F).
Target Size 57 mm (2.25 in).
Target Emissivity 0.95 (± 0.02 from 8 to 14 µm).
Resolution 0.1°.
Heating time 15 minutes (25 °C to 150 °C).
Cooling time 15 minutes (25 °C to –20 °C).
Computer Interface RS-232 I/O included with 9930 Interface-it software.
Power 115 V ac (± 10 %), 1.5 A, or
230 V ac (± 10 %), 1.0 A,
switchable, 50/60 Hz, 200 W.
Dimensions (H x W x D) 152 x 286 x 267 mm (6 x 11.25 x 10.5 in).
Weight 4.6 kg (10 lb).
NIST-Traceable Contact Calibration Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C.
Fluke 9133 warranty One year.