loading spinner
Fluke 4180-256 Precision Infrared Calibrator
  • Fluke 4180-256 Precision Infrared Calibrator
  • Fluke 4180-256 Precision Infrared Calibrator

Fluke 4180-256 Precision Infrared Calibrator

Fluke Approved distributor and certified product specialist

lead time  Lead Time Approx. 7-14 Days.


Includes: Fluke 4180 IR Calibrator, Report of Calibration, Power Cord, User’s Guide, Documentation CD, Target Cover, Serial Cable.

3109525
£7382.00
£8858.4 Inc. VAT

The Fluke 4180 Precision Infrared Calibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations.

The Fluke 4180 Infrared Temperature Calibrator reaches temperatures from –15 °C to 120 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.

Unique patent pending safety features make the instrument the safest IR calibrator available. The Block Temperature Indicator shows the user when the target temperature is above 50°C letting the user know when it is safe to place the target cover on the instrument and/or move it to a different location. The indicator remains illuminated when the instrument is energised and above 50°C, but with mains power removed, it will flash until the target temperature drops below 50°C.

In addition, with accuracies as good as ± 0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1. The Fluke 4180 IR Calibrator is designed in accordance with IEC 61010-1, IEC 61010-2-010 and CAN/CSA 22.2 No 61010.1-04. The uniformity and stability are so good that variations can’t be detected with a thermal imager.

FEATURES

Rapid heating and cooling.
RS-232 interface capability.
Eight set-point memory.
Adjustable readout in °C or °F.
Adjustable Emissivity.
Calibrated radiometrically for meaningful, consistent results.
Intuitive, easy-to-read display that indicates when temperature is stable.

Fluke 4180-256 Product Video

Fluke 4180-256 Specifications
Temperature range (@ 23 °C ambient, 0.95 emissivity) –15 °C to 120 °C.
Display accuracy1 ± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C.
Stability ± 0.10 °C at –15 °C
± 0.05 °C at 0 °C
± 0.10 °C at 120 °C.
Uniformity (5.0 in dia of center of target)2 ± 0.15 °C at –15 °C
± 0.10 °C at 0 °C
± 0.25 °C at 120 °C.
Uniformity (2.0 in dia of center of target)2 ± 0.10 °C at -15 °C
± 0.10 °C at 0 °C
± 0.20 °C at 120 °C.
Heating time 15 min: –15 °C to 120 °C
14 min: 23 °C to 120 °C.
Cooling time 15 min: 120 °C to 23 °C
20 min: 23 °C to –15 °C.
Stabilisation time 10 minutes.
Nominal emissivity3 0.95.
Thermometer emissivity compensation 0.9 to 1.0.
Target diameter 152.4 mm (6 in).
Computer interface RS-232.
Power 115 V ac (± 10%), 6.3 A,
50/60 Hz, 630 W
230 V ac (± 10%), 3.15 A,
50/60 Hz, 630 W.
Fuse(s) 115 V ac 6.3 A, 250 V, slow blow
230 V ac 3.15 A, 250 V, T.
Safety EN 61010-1:2001, CAN/CSA C22.2 No. 61010.1-04.
Dimensions (H x W x D) 356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in).
Weight 9.1 kg (20 lb).
NIST-Traceable Contact Calibration Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C.
Fluke 4180 warranty One year.
1For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0
2The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature.
3The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.

Download

Fluke 4180 + 4181 Datasheet

PDF Specifications of the Fluke 4180 & 4181 Precision IR Calibrators.

Download (2.05M)

No customer reviews for the moment.

Write your review

Fluke 4180-256 Precision Infrared Calibrator
COMPONENT
DESCRIPTION PART No.
4180-APRT 2" Aperture. 3277383
4180-CASE Carrying case. 3109591
4180-DCAS Carrying case with wheels. 3186636
4180-PURGEBOX Purgebox 4180 (plexiglass). 4034585

4 other products in the same category: