Megger MIT300 Insulation & Continuity Tester
Includes: test lead set, crocodile clips and MIT300 User Manual.
Combining both Insulation testing and continuity testing, the Megger MIT300 caters for all aspects of fixed wiring installations. The MIT300 features 250 & 500V insulation ranges, audible continuity test and a safety interlock system which prevents unsafe connection of test leads.
In line with other products in Megger's comprehensive contractor range, MIT300 insulation testers feature rugged construction, with an impact-resistant rubber-overmoulded case, and innovative circuitry which guarantees high accuracy combined with stability of calibration.
All instruments in the MIT300 range provide indication of insulation resistance up to 999Mohms, 200mA continuity testing, a fast-reacting continuity buzzer, and facilities for nulling the resistance of the test leads. The entry-level MIT300 offers insulation test voltages of 250V and 500V, while the remaining models allow testing at 250V, 500V and 1,000V.
Digital and analogue LCD bar graph display.
Megger Intelligent Safety System built in.
250 V and 500 V insulation testing.
Test range of up to 999 MΩ.
Continuity testing to 100 Ω to continuity buzzer.
Voltage warning.
Locking test button.
Auto powerdown.
IP54 weatherproofing.
Insulation voltage | 250 V & 500 V. | ||
Nominal Test Voltage | MIT310: 310 A, 320, 330: 1000 V, 500 V, 250 V (DC) MIT300: 500 V, 250 V (DC). |
||
Measuring Range | 10 kΩ to 999 MΩ on all ranges. | ||
Short Circuit Current | 1.5 mA nominal. | ||
Test Current on Load | 1mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364). | ||
Accuracy (at 20°C) | MIT300, 310, 320, 330: ±3% ± 2 digits up to 10 MΩ, ±5% up to 100 MΩ, ±30% up to full scale MIT310 A: <2.5% of scale length (or 30% of reading 200 kΩ to 10 MΩ). |
||
Continuity | |||
Measuring Range | 0.01 Ω to 99.9 Ω (0-50 Ω on analogue scale). | ||
Open Circuit Voltage | 5 V ± 1 V. | ||
Short Circuit Current | MIT300, 310, 320, 330: 205 mA + 10 mA -5 mA MIT310A: 200-250 mA. |
||
Continuity Accuracy | MIT300, 310, 320, 330: ±3% ± 2 digits MIT310A: ±2.5% of scale length (or 30% of reading 0.2 to 2 kΩ). |
||
Measuring Range | 0-2/20/200/2 kΩ. | ||
Open Circuit Voltage | 1.5V ± 0.5 V. | ||
Zero Offset Adjust | MIT300, 310, 320, 330: 0 - 9Ω MIT310A: 0 to 0.5 Ω. |
||
Continuity Buzzer | MIT300, 310: operates at <5 Ω MIT 320, 330: adjustable from 1 Ω to 20 Ω MIT310A: operates at <5 Ω MIT300, 310, 320, 330: response time <20 ms MIT310: response time <100 ms. |
||
Resistance Range (MIT320/330) | |||
Measuring Range | 10 Ω to 1 MΩ. | ||
Open Circuit Voltage | 5 V. | ||
Short Circuit Current | 1.5 mA. | ||
Accuracy (at 20°C) | ±5 ± 2 digits up to 100 kΩ. | ||
Measuring Range (MIT310A) | 0 to 2 kΩ (refer to continuity). | ||
Voltage Range | |||
Measuring Range | 0 to 600 V AC (50/60 Hz) or DC. | ||
Accuracy (at 20°C) | MIT310, 320, 330: DC or AC (50/60 Hz): ±1% ± 2 digits MIT310A: ±2.5% of scale length for 50/60 Hz. |
||
Temperature Coefficient | <0.1°C per °C on all ranges. | ||
Default Voltmeter | |||
MIT310, 320, 330 | >25 V AC or DC is applied display will operate as a voltmeter. | ||
MIT300 | Beeps and flashes V on the display. | ||
MIT310A | All modes including OFF. | ||
Test Inhibit | If more than 50 V is detected testing will be inhibited. | ||
General | |||
Power | 8 x 1.5 V cells IEC LR6 type(AA alkaline) Rechargeable NiCd or NiMH cells may be used. |
||
Battery life |
5000 consecutive tests (5 seconds per test) on any test using 2Ah batteries.
|
||
EMC | In accordance with IEC61326-1. | ||
Dimensions | 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches). | ||
Weight | 980 g. | ||
Megger MIT300 warranty | 3 years. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Leads & clips | Unfused test lead set and crocodile clips. | 1002-001 | ||
Fused leads | Fused test lead set Red/Black. | 1002-015 | ||
Prod & clips | Prod and clip set - insulation testers. | 1002-491 |