loading spinner
Megger MIT2500 50V to 2500V Insulation Tester
  • Megger MIT2500 50V to 2500V Insulation Tester
  • Megger MIT2500 50V to 2500V Insulation Tester

Megger MIT2500 50V to 2500V Insulation Tester

Megger approved distributor and service centre.

Includes: MIT 2500, Red/Black/Blue silicone test leads with prods and clips, 2.5 kV Red/Black/Blue silicone test leads with clips, Owners Information CD, Batteries 6 x AA Alkaline, Carry Case.

1004-745
Megger
£849.00
£1018.8 Inc. VAT
In Stock

Designed to offer long reliable service even when used in tough on-site conditions, the MIT2500 insulation tester features rugged construction, with resilient rubber over-moulding, and an IP54 protection rating. Designed from the outset with safety in mind, it incorporates live circuit detection and protection functionality, and has a CATIV 600 V safety rating in line with IEC 61010.

The MIT2500 insulation tester has feedback-stabilised test voltages to ensure that tests are always carried out to Megger’s market leading tight specification. The MIT2500 also incorporates a guard terminal that makes it possible to compensate for the effects of surface leakage currents.

The variable mode provides a unique solution for awkward insulation voltage measurement applications. The range option allows an insulation test voltage from 50 V to 999 V in 1 V steps, 1.0 KV to 2.5 KV in 10 V steps.

Typical applications for Megger’s new 2.5 kV insulation tester include testing of cables, motors and generators. In addition, as users can adjust the test voltage in 10 V steps from 100 V to 2.5 kV, the instrument can also be used for testing electrical installations, verifying the ESD of materials and testing of control panels, to name but a few.

FEATURES

Designed for the Electrical and Industrial markets.
Insulation testing up to 2.5 kV (New) and 200 GΩ range in a hand held instrument.
Guard terminal for high resistance accuracy.
Adjustable insulation test voltage from 50 V to 2500 V.
Stabilised insulation test voltage.
Rechargeable options for mains and car charging.
Single range, faster continuity testing from 0.01 Ω to 1 MΩ.
Polarisation Index (PI) & Dielectric Absorption Ratio (DAR).
600 V Trms AC and DC voltage measurement.
New case design with optional magnetic hanging strap.
Test result storage and review and Bluetooth download.
Live circuit detection and protection.
CAT IV 600 V applications.
IP54.

Megger MIT2500 Specifications
Insulation
Insulation Accuracy 50 Volts: 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ
100 Volts: 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ
250 Volts: 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ
500 Volts: 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ
1000 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
2500 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ
Service Error: BS EN 61557-2 (2007).
50V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5%
100V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
250V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
500V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3%
1000V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 11.5%
Guard Terminal Performance <5% erros on 500 kΩ parallel circuit resistance with 100 MΩ load.
Display Range Analogue: 1 GΩ full scale.
Short Circuit/Charge Current 2mA +0 to -50% t EN 61557-2 (2007) (except 2500 V).
Terminal Voltage Accuracy -0 +2% ±2 V.
Test Current 1mA at minimum pass values of insulation to a maximum of 2 mA max.
Operation EN61557: 0.10 MΩ to 1.0 GΩ.
Leakage Current Display 10% ±3 digits.
Voltage ±3% ±2 digits ±0.5% of rated voltage.
Timer Control Countdown timer 60 seconds (adjustable to 10 minutes).
Note Above specs only apply when high quality silicone leads are used.
Continuity
Continuity Measurement 0.01Ω to 1MΩ (0 to 1000kΩ on analogue scale).
Continuity Accuracy ± 3% ± 2 digits (0 to 100 Ω )
± 5% ± 2 digits (100 Ω - 500 k Ω)
Service Error: BS EN 61557-4 (2007) -
± 2.0%, 0.1 Ω - 2 Ω ± 6.8%.
Open Circuit Voltage 5V ±1V.
Test Current 200 mA (-0 mA to +20 mA)
(0.01 Ω to 4 Ω).
Polarity Single polarity (default) / dual polarity (configurable on setup).
Lead Resistance Null Up to 10 Ω.
Voltage
Voltage Range DC: 0 to 600 V
AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 HZ)
Unspecified: 0 to 10 mV (15 to 400 Hz).
Voltage Range Accuracy DC: ±2% ±2 digits
AC: ±2% ±2 digits
Service Errors: BS EN 61557-1 (2007) - ±2.0% ±2d. 0 V to 300 V AC/DC ±5.1%.
Waveform Non-sinusoidal:
± 3% ± 2 digits >100 mV to 600 V TRMS
± 8% ± 2 digits 10 mV to 100 mV TRMS.
Frequency
Measurement Range 15 to 400 Hz.
Accuracy ±0.5% ± 1 digit.
Capacitance
Range 0.1 nF to 10 μF.
Accuracy ±5.0% ±2 digits (1 nf to 10 μF).
General Specifications
Storage Capacity >1000 test results.
Data Download Bluetooth wireless
Bluetooth class II.
Range Up to 10 m.
Power Supply 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) alkaline
6 x 1.2 NiMH rechargeable cells may be used.
Battery Life 3000 insulation tests with duty cycle of 5 sec ON/55 sec OFF @ 1000 V into 1 MΩ Charger (optional)
12-15 V DC (accessory interface).
Fuse Use only 2 x 500 mA (FF) 1000V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum.
Safety Protection Meets EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
EMC In accordance with IEC 61326 including amendment No 1.
Temperature Coefficient <0,1% per °C up to 1 GΩ
<0,1% per °C per GΩ above 1 GΩ.
Operating Temperature Range -10 to +55°C.
Storage Temperature Range -25 to +70°C
Humidity 90% RH at 40°C max
Calibration Temperature +20°C
Maximum Alititude 2000m
IP Rating IP54.
Dimensions 228 x 108 x 63 mm.
Weight 815g.
Megger MIT2500 warranty One-year.

Download

Megger MIT2500 Datasheet

PDF Specifications of the Megger MIT2500 Insulation and Continuity Tester.

Download (355.98k)

No customer reviews for the moment.

Write your review

Megger MIT2500 50V to 2500V Insulation Tester
COMPONENT
DESCRIPTION PART No.
Battery Charger Mains Charger kit . 1007-464
Car Charger 12 V DC car charger (requires mains charger kit). 1004-183
SP5 Remote switched probe SP5. 1007-157
Leads & Crocs Unfused test lead set and crocodile clips, Red/Black. Boxed. 1002-001B

16 other products in the same category:

arrow_upward