Megger MIT2500 50V to 2500V Insulation Tester
Includes: MIT 2500, Red/Black/Blue silicone test leads with prods and clips, 2.5 kV Red/Black/Blue silicone test leads with clips, Owners Information CD, Batteries 6 x AA Alkaline, Carry Case.
Designed to offer long reliable service even when used in tough on-site conditions, the MIT2500 insulation tester features rugged construction, with resilient rubber over-moulding, and an IP54 protection rating. Designed from the outset with safety in mind, it incorporates live circuit detection and protection functionality, and has a CATIV 600 V safety rating in line with IEC 61010.
The MIT2500 insulation tester has feedback-stabilised test voltages to ensure that tests are always carried out to Megger’s market leading tight specification. The MIT2500 also incorporates a guard terminal that makes it possible to compensate for the effects of surface leakage currents.
The variable mode provides a unique solution for awkward insulation voltage measurement applications. The range option allows an insulation test voltage from 50 V to 999 V in 1 V steps, 1.0 KV to 2.5 KV in 10 V steps.
Typical applications for Megger’s new 2.5 kV insulation tester include testing of cables, motors and generators. In addition, as users can adjust the test voltage in 10 V steps from 100 V to 2.5 kV, the instrument can also be used for testing electrical installations, verifying the ESD of materials and testing of control panels, to name but a few.
FEATURES
Designed for the Electrical and Industrial markets.
Insulation testing up to 2.5 kV (New) and 200 GΩ range in a hand held instrument.
Guard terminal for high resistance accuracy.
Adjustable insulation test voltage from 50 V to 2500 V.
Stabilised insulation test voltage.
Rechargeable options for mains and car charging.
Single range, faster continuity testing from 0.01 Ω to 1 MΩ.
Polarisation Index (PI) & Dielectric Absorption Ratio (DAR).
600 V Trms AC and DC voltage measurement.
New case design with optional magnetic hanging strap.
Test result storage and review and Bluetooth download.
Live circuit detection and protection.
CAT IV 600 V applications.
IP54.
Insulation | |
---|---|
Insulation Accuracy | 50 Volts: 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ 100 Volts: 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ 250 Volts: 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ 500 Volts: 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ 1000 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ 2500 Volts: 200 GΩ ± 2% ± 2 digits ± 0.2% per GΩ Service Error: BS EN 61557-2 (2007). 50V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5% 100V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 250V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 500V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 1000V: ± 2.0% ± 2d, 100kΩ - 900kΩ ± 11.5% |
Guard Terminal Performance | <5% erros on 500 kΩ parallel circuit resistance with 100 MΩ load. |
Display Range | Analogue: 1 GΩ full scale. |
Short Circuit/Charge Current | 2mA +0 to -50% t EN 61557-2 (2007) (except 2500 V). |
Terminal Voltage Accuracy | -0 +2% ±2 V. |
Test Current | 1mA at minimum pass values of insulation to a maximum of 2 mA max. |
Operation | EN61557: 0.10 MΩ to 1.0 GΩ. |
Leakage Current Display | 10% ±3 digits. |
Voltage | ±3% ±2 digits ±0.5% of rated voltage. |
Timer Control | Countdown timer 60 seconds (adjustable to 10 minutes). |
Note | Above specs only apply when high quality silicone leads are used. |
Continuity | |
Continuity Measurement | 0.01Ω to 1MΩ (0 to 1000kΩ on analogue scale). |
Continuity Accuracy | ± 3% ± 2 digits (0 to 100 Ω ) ± 5% ± 2 digits (100 Ω - 500 k Ω) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1 Ω - 2 Ω ± 6.8%. |
Open Circuit Voltage | 5V ±1V. |
Test Current | 200 mA (-0 mA to +20 mA) (0.01 Ω to 4 Ω). |
Polarity | Single polarity (default) / dual polarity (configurable on setup). |
Lead Resistance | Null Up to 10 Ω. |
Voltage | |
Voltage Range | DC: 0 to 600 V AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 HZ) Unspecified: 0 to 10 mV (15 to 400 Hz). |
Voltage Range Accuracy | DC: ±2% ±2 digits AC: ±2% ±2 digits Service Errors: BS EN 61557-1 (2007) - ±2.0% ±2d. 0 V to 300 V AC/DC ±5.1%. |
Waveform | Non-sinusoidal: ± 3% ± 2 digits >100 mV to 600 V TRMS ± 8% ± 2 digits 10 mV to 100 mV TRMS. |
Frequency | |
Measurement Range | 15 to 400 Hz. |
Accuracy | ±0.5% ± 1 digit. |
Capacitance | |
Range | 0.1 nF to 10 μF. |
Accuracy | ±5.0% ±2 digits (1 nf to 10 μF). |
General Specifications | |
Storage Capacity | >1000 test results. |
Data Download | Bluetooth wireless Bluetooth class II. |
Range | Up to 10 m. |
Power Supply | 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) alkaline 6 x 1.2 NiMH rechargeable cells may be used. |
Battery Life | 3000 insulation tests with duty cycle of 5 sec ON/55 sec OFF @ 1000 V into 1 MΩ Charger (optional) 12-15 V DC (accessory interface). |
Fuse | Use only 2 x 500 mA (FF) 1000V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. |
Safety Protection | Meets EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. |
EMC | In accordance with IEC 61326 including amendment No 1. |
Temperature Coefficient | <0,1% per °C up to 1 GΩ <0,1% per °C per GΩ above 1 GΩ. |
Operating Temperature Range | -10 to +55°C. |
Storage Temperature Range | -25 to +70°C |
Humidity | 90% RH at 40°C max |
Calibration Temperature | +20°C |
Maximum Alititude | 2000m |
IP Rating | IP54. |
Dimensions | 228 x 108 x 63 mm. |
Weight | 815g. |
Megger MIT2500 warranty | One-year. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Battery Charger | Mains Charger kit . | 1007-464 | ||
Car Charger | 12 V DC car charger (requires mains charger kit). | 1004-183 | ||
SP5 | Remote switched probe SP5. | 1007-157 | ||
Leads & Crocs | Unfused test lead set and crocodile clips, Red/Black. Boxed. | 1002-001B |