loading spinner
Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter

Fluke 1587 FC Insulation Multimeter

Fluke authorised distributor and calibration house.

Includes: Fluke 1587 FC, Remote probe, Test leads, Alligator clips, K-type thermocouple, Hard case, User documentation.

4691215
£599.00
£718.8 Inc. VAT
In Stock

Developed for commercial and industrial applications, the Fluke 1587 FC Insulation Multimeter is the only meter that gives you a high-performance DMM, a state-of-the-art insulation tester, and wireless connectivity for sharing and tracking results all in one unit.

The 1587 FC supports the Fluke Connect™ Wireless System. Fluke Connect™ is a system that wirelessly connects your Meter with an app on your smartphone or tablet. The app shows the Meter measurement on your smartphone or tablet screen. You can save these measurements with Fluke Connect™ to share with your team.

The Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through the Fluke Connect® Measurements app:

  1. PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster.
  2. Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time.
  3. Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons.
  4. Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets.

FEATURES

Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection.
VFD low-pass filter for accurate motor drive measurements.
Auto-discharge of capacitive voltage for added user protection.
Insulation test (1587 FC: 0.01 MΩ to 2 GΩ).
AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity, Capacitance, diode test, temperature, Min/Max, frequency (Hz).
Auto power off to save battery power.
Large display with backlight.
Rugged, utility hard case allows you to bring everything you need for the job.
Included accessories: Remote probe, test leads and probes, alligator clips, K-type thermocouple.
Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient hands free operation.
Three-year standard warranty; extendable to five-years through product registration within 45 days of purchase.

Fluke 1587FC Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance  10 MΩ (nominal), <100 pF.
Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz.
Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance).
Accuracies apply to ± 100% of range.
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1).
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA.
Resolution 0.1 mA.
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA.
Range 60 mA.
Resolution 0.01 mA .
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA.
DC
Range 400 mA.
Resolution 0.1 mA.
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2).
Burden voltage (Typical) 2 mV/mA.
Range 60 mA.
Resolution 0.01 mA.
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2).
Burden voltage (Typical) 2 mV/mA.
Overload 600 mA for 2 minutes maximum.
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA.
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input.
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection 1000 V rms or dc
Open circuit test voltage <8.0 V dc
Short circuit current <1.1 mA
¹ Accuracies apply from 0% to 100% of range.
² Up to 80% relative humidity.
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current.
Accuracy ±(2% + 3).
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω.
Open circuit voltage <8.0 V.
Short circuit current 1.0 mA typical.
Overload protection 1000 V rms.
Response time >1 m sec.
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz  0.01 Hz ±(0.1% + 1)
999.9 Hz 0.1 Hz ±(0.1% + 1)
9.999 kHz 0.001 kHz ±(0.1% + 1)
99.99 kHz 0.01 kHz ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 mV
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV
DC Trigger Levels¹ to 20 kHz² NA
6.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 1.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 10.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 300.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy.
² Usable to 100 kHz with full scale input.
Capacitance
Range Resolution Accuracy ±(% of Rdg+Counts)
1000 nF 1 nF ±(1.2% + 2)
10.00 μF 0.01 μF ±(1.2% + 2)
100.0 μF 0.1 μF ±(1.2% ±90 counts)
9999 μF 1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
-40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument.
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ.
Test voltages 50, 100, 250, 500, 1000 V.
Test voltage accuracy +20%, -0%.
Short-circuit test current 1 mA nominal.
Auto discharge Discharge time <0.5 second for C = 1 μF or less.
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test.
Maximum capacitive load Operable with up to 1 μF load.
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ
Resolution 100 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V.
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F).
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F).
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F).
Relative humidity Noncondensing.
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F).
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F).
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F).
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument.
Radio frequency communication 2.4 GHz ISM Band.
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE.
Electromagnetic Compatibility
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A.
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment).
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating).
Safety
IEC 61010-1 Pollution Degree 2.
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V.
Batteries Four AA batteries (NEDA 15A or IEC LR6).
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Dimensions (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in).
Weight 550 g (1.2 lb).
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%.
Frequency overload protection <107 V Hz.
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA.

Download

Fluke 1587FC + 1577 Datasheet

PDF Specifications of the Fluke 1587 FC & 1577 Insulation Multimeters.

Download (2.2M)

No customer reviews for the moment.

Write your review

Fluke 1587 FC Insulation Multimeter
COMPONENT
DESCRIPTION PART No.
C25 Soft meter case. 681114
C550 Tool bag. 1547919
AC285 SureGrip™ Alligator Clips. 1610159
TPAK ToolPak™ Magnetic Meter Hanger Kit includes:
9 inch hook and loop strap
Universal hanger clip
Hook hanger for non magnetic surfaces
Strong magnet.
1281997
TL27 Heavy Duty Test Lead Set. 668571
TLK-225 SureGrip™ Master Accessory Set. 3971234
i200 i200 AC Current Clamp (200A). 664755
80PK-8 Pipe Clamp Temperature Probe (Type-K thermocouple). 200360

3 other products in the same category:

arrow_upward