- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Clare HAL 103 AC/DC Hipot Tester
Includes: HAL102 Instruction manual, HT Clip Lead, Hipot Probe & Lead, Power Cord, Guard Plug, Comms cable.
The Clare Hal 103 Safety Electrical Tester (formerly the HAL combi) is a powerful tool to assist in the analysis of the safety of electrical and electronic equipment. A range of tests are provided, with innovative features to aid difficult test situations, which allow testing of a wide variety of equipment.
The HAL 103 is designed for simple manual testing and automatic mode for large volume applications in the most demanding environments. It is designed for use in manufacturing, laboratory, maintenance and high speed production environments either as a stand-alone test instrument or as an integrated part of a production line system.
The HAL 103 has DC and selectable 50 or 60 Hz outputs for flash testing and incorporates a 0-40A constant current low voltage ground bond test. Other features include a large high contrast bar graph display of the test output and measured test parameters. The Clare HAL103 is a fast and efficient automatic industrial test solution, which records results and enables accurate testing to be carried out in line with relevant standards at all times.
FEATURES
Highly accurate Ground Bond, Hipot leakage and DC IR measurements.
Highly accurate leakage and DC IR measurements.
4 wire Ground Bond test measurements.
Usable with the Clare No – Burn Ground Bond probe.
Large Full graphics display, Real-time clock.
Connects to PC, Barcode reader and printer.
Compatible with Seaward PATguard and other leading software packages.
Software adjusts the user interface to differing levels of expertise.
Auto test code generation.
Uses fully Barcode reading for simple & easy tests initiation.
Fast Start-up.
Fully isolated test outputs, to comply with EN50191.
FEATURES | 101 | 102 | 103 | 104 | LED | |
Earth/Ground Bond | ||||||
AC Flash/Hipot | ||||||
DC Flash/Hipot | ||||||
DC Insulation Resistance | ||||||
ARC Detection | ||||||
Leakage | ||||||
Load Power | ||||||
Load Power (200mVA resolution) | ||||||
Power Factor | ||||||
Results Memory | ||||||
Automation Option | ||||||
Barcode scanner/printer Option | ||||||
Internal scanner |
Earth Ground/Bond Test | |
---|---|
Test Voltage | 6 V AC (nominal). |
Frequency | 50 or 60 Hz (independent of supply). |
Display Range and Accuracy | 0 to 1500 mΩ - ±2% ±5 counts. |
Display Resolution | 1 mΩ. |
Compliance Test Ranges | |
Current/Load Resistance/Time | 5 A, 1000 mΩ - continuous 10 A, 500 mΩ - continuous 25 A, 200 mΩ - continuous 30 A, 150 mΩ - 60 seconds 40 A, 100 mΩ - 60 seconds. |
Settable Output Current Range | 0.1 to 40.0 A. |
Selectable Range of PASS/FAIL Levels | 0 to 1500 mΩ. |
Insulation Resistance Test | |
DC Output Voltage | 0.10 kV to 6.00 kV (10 V/step when manually adjusted) (50 V/step in test sequence program). |
Display Range | 0.01 MΩ to 500 MΩ. |
Display Range/Accuracy | 0.03 MΩ to 350 MΩ: ±5% ± 5 counts 350 MΩ to 500 MΩ: indication only. |
Display Resolution | 0.01 MΩ. |
PASS/FAIL Level | 0.00 MΩ to 500.0 MΩ. |
AC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 5.00 kV (10 Vstep when manually adjusted) 50 V/step in test sequence program). |
Frequency (Independent of Supply) | 50 or 60 Hz. |
Voltage Display Range/Accuracy | 0.10 kV to 5.00 kV: ±1% ±5 counts. |
Voltage Display Resolution | 0.01 kV. |
Current Display Range/Accuracy | 0.01 mA to 20.00 mA: ±1% ± 5 counts. |
Current Display Resolution | 0.01 mA. |
Selectable Range of PASS/FAIL Levels | 0.01 mA to 20.00 mA. |
Maximum Current Output | 20.00 mA @ 5 kV. |
Optional Arc Detection | 9 levels. |
DC Dielectric Strength Test | |
Programmable Voltage Range | 0.10 to 6.00 kV (10 V/step when manually adjusted) (50 V/step in test sequence program). |
Voltage Display Range and Accuracy | 0.10 to 6.00 kV: ±1% ±5 counts. |
Voltage Display Resolution | 0.01 kV. |
Current Display Range and Accuracy | 0.01 mA to 10.00 mA: ±1% ±5 counts. |
Current Display Resolution | 0.01 mA. |
Selectable Range of PASS/FAIL Levels | 0.01 mA to 10.00 mA. |
Maximum Current Output | 10.00 mA. |
Optional Arc Detection | 9 levels. |
General Specifications | |
Operating Voltage Range | Selectable: 115 to 230 V AC RMS, 50/60 Hz. |
EN50191 | Compliant when used with appropriate accessories. |
Dimensions | 200 x 300 x 370 mm (W x H x D). |
Weight | 15 kg approx. |
Clare HAL 104 warranty | 1 year warranty subject to product registration with Seaward. |
No customer reviews for the moment.
COMPONENT PARTS | DESCRIPTION | PART No. | ||
Earth Test Probe | Earth probe compatible with HAL series. | 01520/1 | ||
Hipot Test - Probe | Test probe for use with HAL series - 2 metres. | 03914/2 | ||
Handheld Guard Switch | Handheld guard switch compatible with the HAL series. | DCS317 | ||
Warning Beacon | Status Beacon For Hal Series. | H-5017 |