- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Fluke TiS75+ 9Hz Thermal Camera
Includes: TiS75+ Thermal imager, AC charger/power supply with worldwide adapters for battery charging and AC operation, Two smart lithium ion smart batteries and charging bay, USB cable, Soft transport bag, Micro SD Card, Adjustable hand strap, Rugged, hard carrying case, Statement of factory calibration, Quick start guide, Safety sheet.
The Fluke TiS75+ Thermal Imager is a handheld, infrared imaging camera for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development.
The TiS75+ displays thermal images on a high-visibility, industrial-quality LCD touch screen. It can save images to internal memory or to a removable memory card. Saved images and data stored in the internal memory or on the memory card can be transferred to a PC through a direct USB connection to the PC or by wireless transfer to a PC or mobile device. The Imager works with the Fluke Connect app available on mobile devices and with the Fluke Connect software available for PCs. A rugged, rechargeable lithium-ion smart battery provides power to the Imager. Direct ac power is accessible with the included ac power adapter.
Take your plan for a proactive maintenance (PM) program and turn it into reality. To get started, you need features that make it easy to set up your image organization and inspection routines. With the TiS75+ you’re well on your way to implementing a successful PM program.
FEATURES:
384 x 288 infrared resolution.
-20 °C to 550 °C temperature range.
3.5" VGA Touchscreen LCD display.
Manual and fixed focus.
Picture-in-Picture mode.
Water and dust resistant (IP54).
Engineered to withstand a 2-meter drop.
Fluke Connect enabled.
Model | TiS75+ | TiS55+ |
Infrared resolution | 384 x 288 (110,592 pixels) | 256 x 192 (49,152 pixels) |
IFOV | 1.91 mRad | 1.91 mRad |
Field of view | 42° x 30° | 28° x 20° |
Minimum focus distance | 0.5 m | 0.5 m |
Focus system | Manual focus and 1 meter focus marker | Manual focus and 1 meter focus marker |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types —whether mechanical, electrical or infrared images—in one location |
Yes*, assign images to assets and create work orders. Easily compare measurement types —whether mechanical, electrical or infrared images—in one location |
Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
IR-Fusion technology | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
Picture-In-Picture (PIP) | Yes | Yes |
Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
Ergonomic design | Designed for one-handed use | Designed for one-handed use |
Thermal sensitivity | 40 mk | 40 mk |
Level and span | Smooth auto and manual scaling | Smooth auto and manual scaling |
Fast auto-rescale in manual mode | Yes | Yes. |
Minimum span (in manual mode) | 3° °C (4.5 °F) | 3° °C (4.5 °F). |
Minimum span (in auto mode) | 5°C (9.0 °F) | 5°C (9.0 °F). |
Built-in digital camera (visible light) | Up to 5mp | Up to 5mp. |
Frame rate | 9 Hz or 27 Hz models. | 9 Hz or 27 Hz models. |
Dew point calculation | Yes, on camera | No. |
Data Storage and Image Capture | ||
Internal memory | ~500 images | ~500 images |
External memory | ≥4 GB SD card (>1000 images) | ≥4 GB SD card (>1000 images) |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
One-handed image capture, review, and save capability |
Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 | Non-radiometric BMP or JPEG or fully-radiometric is2 |
Memory review | Yes | Yes |
Software | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect | Fluke Connect software - full analysis and reporting software with access to the Fluke Connect |
Analyse and store radiometric data on a PC | Yes | Yes |
Export file formats with Fluke Connect Software | is3, is2, BMP, GIF, JPEG, PNG, TIFF | is2, BMP, GIF, JPEG, PNG, TIFF |
Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. |
IR-PhotoNotes | Yes. Up to 3 extra user-selectable visible light image capture to be included in IS2 file. | Yes. Up to 1 extra user-selectable visible light image capture to be included in IS2 file. |
Text annotations | After IS2 capture, user can type in a note using on-screen keyboard. | After IS2 capture, user can type in a note using on-screen keyboard. |
Video recording and formats | Standard and radiometric video. Up to 5 minutes recording length. avi and is3 | No |
Remote control operations | Yes | No |
Auto capture (temperature and interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files. | Yes. User-selectable time interval for capturing IS2 or Jpeg files. |
Battery | ||
Batteries (field-replaceable, rechargeable) |
Lithium-ion rechargeable battery | Lithium-ion rechargeable battery |
Battery life | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
Battery charging time | ≤2.5 hours to full charge | ≤2.5 hours to full charge |
Battery charging system | Ti SBC3B Two-Bay Battery Charger or in-Imager charging. |
Ti SBC3B Two-Bay Battery Charger or in-Imager charging. (does not come with two-bay battery charger) |
AC operation | AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
Power saving | User-selectable sleep and power off | User-selectable sleep and power off |
Temperature Measurement | ||
Temperature range (not calibrated below -10 °C) |
-20 °C to 550 °C (not calibrated below -10 °C) | -20 °C to 550 °C (not calibrated below -10 °C) |
Accuracy | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature |
On-screen emissivity correction | Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
On-screen reflected background temperature compensation |
Yes | Yes |
On-screen transmission correction | Yes | Yes |
Colour Palettes | ||
Standard palettes | 6 | 6 |
General Specifications | ||
Colour alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
>Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
Infrared spectral band | ~8-14μm | ~8-14μm |
Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) | -10 °C to 50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) without batteries |
-20 °C to 50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing |
Spot temperature | Center spot (unmovable) | Center spot (unmovable) |
User-definable spot markers | Yes, 5 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
Yes, 3 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
User-defined measurement boxes | Yes, 5 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
Yes, 3 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap | Rugged hard carrying case with soft transport bag, including adjustable strap |
Safety standards | IEC 61010-1: Pollution Degree 2 | IEC 61010-1: Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
Australian RCM | RCM IEC 61326-1 | RCM IEC 61326-1 |
US FCC | 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
Vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
Shock | 30 g, 11 ms, IEC 60068-2-27 | 30 g, 11 ms, IEC 60068-2-27 |
Drop | Engineered to withstand 2 m drop | Engineered to withstand 2 m drop |
Sized (H x W x L) | ~ (26.7 cm x 10.1 cm x 14.5 cm) ~ (10.5 in x 4.0 in x 5.7 in) |
26.7 cm x 10.1 cm x 14.5 cm (10.5 in x 4.0 in x 5.7 in) |
Weight (battery included) | ≤2.27 kg (5 lb) | ≤2.27 kg (5 lb) |
Enclosure rating | IP54 | IP54 |
Warranty | Two-years (standard) | Two-years (standard) |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS compliant | Yes | Yes |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Probe & Clip Set | 10 A Fused test probe and clip lead set. | 1013-224 | ||
Lead Set | DLRO2 current and potential leadset 2m. 2 x red lead, 2 x blk lead, 2 x grabber clip, 2 x probe. | 1011-673 | ||
Right-angled Adaptors | 4 right angled adaptors to allow hook terminated (E.g. KC100) leads to fit DLRO2. | 1012-511 | ||
Probe Pins/Tips | Set of 4 Kelvin probe pins. Replacement probe tips. | 1012-064 | ||
50m Cable Reel | KC50C-KIT Kelvin clamp/probe reel (50 m). | 1013-211 | ||
100m Cable Reel | KC100C-KIT Kelvin clamp/probe reel (100 m). | 1013-212 | ||
50m Ext. Reel | KC50E Extension reel (50 m). | 1013-213 |