loading spinner
Fluke ii900 Sonic Industrial Imager
  • Fluke ii900 Sonic Industrial Imager
  • Fluke ii900 Sonic Industrial Imager
  • Fluke ii900 Sonic Industrial Imager
  • Fluke ii900 Sonic Industrial Imager

Fluke ii900 Sonic Industrial Imager

fluke Approved distributor

lead time   Lead Time Approx. 14-21 Days.


Includes: Fluke ii900 Imager, AC power supply and battery pack charger (including universal AC adapters), Two rugged lithium ion smart battery packs, USB cable, Rugged, hard carrying case, Adjustable hand strap and neck strap.

5075603
£15353.90
£18424.68 Inc. VAT
In Stock

Leaks in compressed air, gas and vacuum systems hit both production uptime and the operations bottom line.

Equipped with an array of microphones for an expanded field-of-view, the hand-held Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments.

With minimal training, your maintenance technicians can begin checking for air leaks during their typical maintenance routine–even during peak operation hours.

This industrial imager offers a new way to locate issues using sound. It is an intuitive, simple to use tool that can isolate the frequency of leaks or vacuums, even in extremely noisy production environments. A leak location is determined by discerning the direction from which a sound originates by the time delays that occur as the sound passes over an array of microphones. A SoundMap™ is displayed in colour over a visual image allowing for easy visual location. With the full array of microphones, it is easy to scan a large area and even capture leaks from a distance.

FEATURES

Do more with the same air compressors – delay the capital expense of installing an additional compressor.
Ensure proper air pressure to your pneumatic equipment.
Lower energy costs.
Reduce leak detection time
Improve reliability in your production line.
Make leak detection part of your typical maintenance routine.
Train the team in a matter of minutes.
Validate repairs on the spot.

Fluke ii900 Product Introduction

Fluke ii900 Specifications
Sensors
# of microphones 64 digital MEMS microphones.
Frequency band 2 kHz to 52 kHz.
Sound pressure sensitivity Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet
(Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters).
Operation distance range 0.5 to > 50 meters (1.6 to > 164 feet).
Field of View 63 ° ± 5 °.
Minimum Frame Rate 12.5 FPS.
Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °.
Focus Fixed lens.
Display 7" LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels).
Touchscreen Capacitive.
Acoustic Image Yes, SoundMap™ image.
Image storage
Storage capacity Internal memory with the capacity for 999 picture files or 20 video files.
Image format Blended visual and SoundMap™.JPG or .PNG.
Video format Blended visual and SoundMap™.MP4.
Video length 30 seconds.
Digital export USB-C for data transfer.
Acoustic Measurements
Measurement range 29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz.
Auto max/min dB gain Auto or manual, user selectable.
Frequency band selection User selectable through user-made presets or manual entry.
Software
Ease of use Intuitive user interface.
Trend graphs Frequency and dB scale.
Spot markers dB level reading at center point of the image.
Battery
Batteries (field-replaceable, rechargeable) Rechargeable Li-ion, Fluke BP291.
Battery life 6 hours (product includes spare battery).
Battery charging time 3 hours.
Battery charging system External dual-bay charger, EDBC 290.
General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red.
Operating Temperature 0 °C to 35 °C (32 °F to 95 °F).
Storage Temperature -20 °C to 70 °C (-4 °F to 158 °F).
Relative humidity 10 % to 95 % non-condensing.
Size (H x W x L) 186 mm x 322 mm x 68 mm.
Weight (battery included) 1.7 kg (3.75 pounds).
Main unit rating IP40 protection against particles 1mm or greater and dripping water.
Sensor head rating IP51.
Warranty Two-year.
Self-diagnostic notification Array-health test to identify when microphone array needs attention.
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese.
RoHS compliant Yes.
Safety
General Safety IEC 61010-1.
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication).
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Download

Fluke ii900 Datasheet

PDF Specifications of the Fluke ii900 Sonic Industrial Imager.

Download (842.84k)

No customer reviews for the moment.

Write your review

Fluke ii900 Sonic Industrial Imager

15 other products in the same category:

arrow_upward