Fluke 721Ex-1601 1.1 - 6.9 Bar Dual Sensor Pressure Calibrator
Includes: Fluke 721 Ex-1601 Dual Sensor Pressure Calibrator, 16 PSIG, 100 PSIG, Soft case, Four (4) AA batteries, Manual, Traceable calibration certificate, Test leads.
Low Pressure Sensor: -14 psi to +16 psi, -0.97 bar to 1.1 bar. High Pressure Sensor: -12 psi to +100 psi, -0.83 bar to 6.9 bar.
The Fluke 721 Ex Pressure Calibrator is a simple to use and versatile pressure calibrator. The two internal pressure sensors are configured with different pressure measurement ranges. One range for lower pressure (P1) and one range for higher pressure (P2). The Fluke 721 Ex features inputs for mA, switch contacts, and an RTD probe. With IECEx and Atex Ex ia IIB T3 Gb (Zone 1) ratings, the 721Ex is available in 14 models and can be used with a Fluke 720RTD probe for temperature measurement. The rugged dual-range pressure calibrator features two isolated, stainless steel, pressure sensors with accuracies to ±0.025 per cent full scale.
The 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
The Fluke 721 Ex has been designed for use in Ex-Hazardous Areas. These are areas where potentially flammable or explosive vapors may occur. These areas are referred to as hazardous (classified) locations in the United States, as Hazardous Locations in Canada, as Potentially Explosive Atmospheres in Europe and as Explosive Gas Atmospheres by most of the rest of the world.
FEATURES
Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1).
Ideal for gas flow calibration (custody transfer) applications.
Two isolated, stainless steel, pressure sensors with 0.025 % accuracy.
Pt100 RTD input for temperature measurement, (probe optional).
Switch test on both pressure inputs.
Pressure displayed in the user’s choice of 19 engineering units.
Large backlit graphic display can display up to three inputs simultaneously.
Store five instrument setups for recall and use.
Specifications 1-Year | |||
Fluke-721Ex-1601 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +100 psi, -0.83 bar to 6.9 bar |
0.01 psi, 0.0001 bar |
0.025% of full scale | |
Fluke-721Ex-1603 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +300 psi, -0.83 bar to 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1605 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1610 | Low pressure sensor | ||
0 psi to +1000 psi, 0.00 bar to 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1615 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1630 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-1650 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
Fluke-721Ex-3601 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 to +100 psi, -0.83 bar to 6.9 bar |
.01 psi, 0.0001 bar |
0.025% of full scale | |
Fluke-721Ex-3603 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +300 psi, -0.83 bar to 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3605 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3610 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1000 psi, 0.00 bar to 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3615 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-3630 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-3650 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
General Specifications | |||
Instrument setup recall | Last used on power-up. | ||
Environmental | Operating temperature -10°C to +45°C Storage temperature (without batteries) -20°C to +60°C. |
||
Altitude | 2,000 m. | ||
Ingress protection | IP-40. | ||
Power requirements | 6.0 V DC. | ||
Battery life | >35 hours, typical usage. | ||
Batteries required | (4) Standard AA cells. | ||
Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm). | ||
Weight | 03539 kg (1 lb 3 oz). | ||
Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe. | ||
Electrical and Temperature Measurement 1-Year | |||
Function | Range | Resolution | Accuracy |
mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
Temperature Effect | |||
No effect on accuracy on all functions from 15°C to 35°C. | |||
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C. | |||
Available Pressure Engineering Units | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F. | |||
Available Pressure Engineering Units | |||
ATEX | Ex ia IIB T3 Gb (Ta= -10… +45 °C). | ||
KEMA 10 ATEX 0168X. | |||
IECEx | Ex ia IIB T3 Gb (Ta= -10…+45 °C). | ||
II 2 G IECEx CSA 10.0013X. |