loading spinner
  • Reduced price
Testo 330i Flue Gas Analyser
  • Testo 330i Flue Gas Analyser
  • Testo 330i Flue Gas Analyser
  • Testo 330i Flue Gas Analyser
  • Testo 330i Flue Gas Analyser

Testo 330i - Set 1 Flue Gas Analyser

Testo Approved distributor and service company.

Includes: testo 330i with standard CO sensor, O2 sensor, Modular flue gas probe with hose (300 mm), testoFix probe mount, Charger, Spare particle filters, and Instrument case for testo 330i.

0563 3000 70
Testo
£1,089.00
£980.10 Save 10%
Tax excluded
Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

Testo 330i - Set 1  with Standard CO/O2 Sensors.

The Testo 330i is a flue gas measuring instrument which in combination with a separate Android or iOS mobile device and the testo 330i App enables professional flue gas analysis of combustion systems

The operation of the Testo 330i instrument and the display of the measurement values take place by Bluetooth via the testo 330i App on your Smartphone/tablet. This means you always have all relevant values at your fingertips right where you need them. After finishing the measurement, you can insert comments or photos of the plant into your report, and send it to your customer or your office by e-mail.

The Testo 330i is the combination of proven technology and revolutionary handling. The basis of the flue gas analyser is the measurement technology of the proven predecessor testo 330 LL, with these outstanding features:

Longlife sensors with up to 6 years' lifetime, exchangeable by the user.
TÜV-tested according to 1. BImSchV (VDI 4206) and EN 50379, Parts 1-3.
Integrated gas and draught zeroing without probe removal.
Measuring range extension up to 30,000 ppm CO through automatic fresh air dilution.

These systems can be adjusted using the instrument and checked for compliance with the applicable limit values. The instrument has been verified as a short-term measuring instrument and should not be used as a safety (alarm) instrument. The following tasks can also be carried out using the instrument:

Regulating the O2, CO and CO2, NO, NOx values in furnaces for the purpose of ensuring optimal operation.
Draught measurement.
Measuring and regulating the gas flow pressure in gas water heaters.
Measuring and optimising the flow and return temperatures of heating systems.
Ambient measurement - CO and CO2.
Detection of CH4 (methane) and C3H8 (propane).

330i FEATURES

Measurement location-independent operation and Bluetooth measurement value display via Smartphone/tablet and testo 330i App.
Non-paper documentation and report creation directly on site with the testo 330i App.
Reliable flue gas probe attachment with the testoFix probe mount.
Robust, completely sealed plastic housing for use in tough conditions.

Testo 330i Product Video

Testo 330i Specifications
Measuring range 0 to 300 hPa.
Accuracy ±0.5 hPa (0.0 to +50.0 hPa)
±1 % of mv (+50.1 to +100.0 hPa)
±1.5 % of mv (Remaining Range).
Resolution 0.1 hPa.
Flue gas O2
Measuring range 0 to 21 Vol.%.
Accuracy ±0.2 Vol.%.
Resolution 0.1 Vol.%.
Flue gas CO (with H₂-compensation)
Measuring range 0 to 8000 ppm.
Accuracy ±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm).
Resolution 1 ppm.
CO determination (with H₂-compensation), automatic dilution
Measuring range 0 to 30000 ppm.
Accuracy ±200 ppm or ±20 % of mv (0 to 30000 ppm).
Resolution 1 ppm.
Flue gas NO
Measuring range 0 to 3000 ppm.
Accuracy ±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm).
Resolution 1 ppm.
Option
Flue gas Draught
Measuring range -9.99 to +40 hPa.
Accuracy ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (3.01 to +40.00 hPa) (the greater value applies).
Resolution 0.01 hPa.
Temperature
Measuring range -40 to +1200 °C.
Accuracy ±0.5 °C (0.0 to +100.0 °C)
±0.5 % of mv (Remaining Range).
Resolution 0.1 °C (-40 to +999.9 °C)
1 °C (Remaining Range).
Dependent on the thermocouple.
Flue gas degree of effectivity, Eta (calculated)
Measuring range 0 to 120 %.
Resolution 0.1 %.
Flue gas loss (calculated)
Measuring range 0 to 99.9 %.
Resolution 0.1 %.
Flue gas CO2 calculation (calculated from O2)
Measuring range Display range 0 to CO₂ max.
Accuracy ±0.2 Vol.%.
Resolution 0.1 Vol.%.
General technical data
Dimensions 270 x 160 x 57 mm.
Operating temperature -5 to +45 °C.
Power supply Rech. batt. block 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A (optional).
System requirements requires iOS 7.1 or newer; requires Android 4.3 or newer; requires mobile end device with Bluetooth 4.0.
Maximum memory 500000 readings.
Storage temperature -20 to +50 °C.
Weight 720 g (excluding battery).

Download

Testo 330i Datasheet

PDF Datasheet of the Testo 330i Flue Gas Set.

Download (471.37k)

No customer reviews for the moment.

Write your review

Testo 330i - Set 1 Flue Gas Analyser
COMPONENT
DESCRIPTION PART No.
TestoFix TestoFix probe mount for flue gas probes with 8 mm diameter. 0554 3006
Case Plastic case for the testo 330i flue gas analyzer and its accessories. 0516 3302
Hose Hose extension; 2.8 m; extension cable for probe. 0554 1202
Cable USB connection cable, instrument-PC. 0449 0047
330i Printer testo 330i BLUETOOTH®-/IRDA printer, incl. 1 roll of thermal paper, rech. battery and mains unit. 0554 0621
Thermal Paper Spare thermal paper for printer, permanent ink. 0554 0568
Probe Set Differential temperature set consisting of 2 Velcro probes and temperature adapter. 0554 1208