Ametek ETC-125A Easy Temperature Calibrator
Includes: 1x ETC-125A calibrator, 1x mains power cable, 1x insertion tube (ETC-125 A only), 1x tool for insertion tube (ETC-125 A only), 1x traceable calibration certificate, 1x RS 232 serial cable, 1x shoulder strap, 1x USB-key containing User-/Reference manual and software package “JOFRACAL”, 1x USB-key containing JOFRA IR-LAB calibration software (ETC-400 R only), 1x correction table for emissivity (ETC-400 R only).
All instrument controls are accessed directly from the front panel. The main functions on the ETC series are designed with one-key-one-function logic. This means that there are no difficult multiple keystrokes to remember to access primary functions. The easy-to-read, backlit display features dedicated icons, which help in identifying instrument conditions and operational steps.
The Jofra ETC-125A has a temperature range of -10 to 125°C (14 to 257°F). The small size and light weight make it a perfect instrument to verify sensors in difficult to reach places.
ETC SERIES FEATURES
Temperature range from -10 to 400°C (14 to 752°F) with 3 models.
Accuracy to ± 0.5°C and Stability to ± 0.05°C.
Time saving fast cooling and heating times.
Easy-to-read multi-information display.
Customizable stability checkmark with countdown timer.
Set exact temperature desired to a resolution of 0.1°C.
ETC 400R, small lightweight IR calibrator.
Lightweight and easy to carry.
Temperature range @ ambient temp. 23°C / 73°F | |
---|---|
Maximum | 125°C / 257°F. |
Minimum @ ambient temp. 0°C / 32°F Minimum @ ambient temp. 23°C / 73°F Minimum @ ambient temp. 40°C / 104°F |
-18°C / -0°F -10°C /14°F 6°C / 43°F. |
Resolution |
|
Selectable | 1º or 0.1º. |
Heating Time | |
-10 to 23°C / 14 to 73°F 23 to 100°C / 73 to 212°F 100 to 125°C / 212 to 257°F |
3 minutes 11 minutes 7 minutes. |
Cooling Time | |
125 to 100°C / 257 to 212°F 100 to 0°C / 212 to 32°F 0 to -10°C / 32 to 14°F |
1 minutes 17 minutes 14 minutes. |
Stability | ±0.05°C / +0.09°F. |
Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. | |
Time to stability | 3 minutes (approximate). |
Accuracy | +0.5°C / +0.9°F. |
General Specifications | |
Immersion depth | 110 mm / 4.3 in (insulation included). |
Voltage AC | 115V (90-132) and 230V (180-264). |
Frequency | 47 - 63 Hz. |
Power consumption (max.) | 75 VA |
Serial data interface | RS232. |
Operating temperature | 0 to 40°C / 32 to 104°F. |
Storage temperature | -20 to 50oC / -4 to 122°F. |
Humidity | 0 to 90% RH. |
Protection class | IP10. |
DNV Marine Approval, Certificate no | A-10384. |
Dimensions (L x W x H) | 172 × 72 × 182 mm / 6.8 × 2.8 × 7.2 in. |
Weight | 1.8 kg / 3.9 lb. |
Ametek ETC-125A warranty | Two-years. |
No customer reviews for the moment.
COMPONENT | DESCRIPTION | PART No. | ||
Case | Carrying case. | 124094 | ||
Strap | Shoulder Strap with Hooks. | 124004 | ||
4mm Brushes | Cleaning Brushes (4 mm; package of 3). | 122832 | ||
6mm Brushes | Cleaning Brushes (6 mm; package of 3). | 60F174 | ||
8mm Brushes | Cleaning Brushes (8 mm; package of 3). | 122822 | ||
Converter | Edgeport converter with 4 RS232 ports. | 125002 | ||
Inserts | Undrilled Inserts. | 123939 | ||
Inserts | Pre-Drilled Inserts (3/8 in.). | 124045 | ||
Inserts | Pre-Drilled Inserts (8 mm). | 123938 |