Druck DPI 822 Thermocouple Loop Calibrator

GE Druck Approved distributor and service company.

Includes: Calibration Certificate, DPI822 User's Manual, Set of Electrical Test Leads and AA Alkaline Batteries.

I822
£885.00
£840.75 Save 5%
Tax excluded
Quantity
  • done HTTPS SECURE: Our pages are encrypted and protected from cyber-attack.
  • done COMPLIANT: Payment Card Industry Data Security Standard (PCI DSS) Compliant.
  • done PROTECTED: by TLS (SSL) - all data/information is secure from interception.

The GE Druck DPI 822 Thermocouple Loop Calibrator provides simultaneous T/C output and mA measurement for transmitter and loop maintenance. The Druck DPI822's 24 V Loop Power Supply energizes transmitters and control loops. An Automatic Switch Test captures open/closed trip values providing a fast and highly accurate "safety system" check. Also a HART Resistor can be switched into the GE Druck DPI-822's loop when required by a HART digital communicator and avoids the inconvenience of carrying a 250Ω resistor.

FEATURES

High performance, low cost.
Measure and source thermocouples.
Advanced cold junction compensation.
Temperature test and maintenance.
Transmitter calibration.
Loop set-up and diagnostics.
Switch verification.

Druck DPI822 Specifications
Type Standard Accuracy Range
K IEC 584 1.1°F (0.6°C) -454°F to 2498°F (-270°C to 1370°C).
J IEC 584 0.9°F (0.5°C) -346°F to 2192°F (-210°C to 1200°C).
T IEC 584 0.6°F (0.3°C) -454°F to 752°F (-270°C to 400°C).
B IEC 584 1.8°F (1.0°C) 122°F to 3308°F (50°C to 1820°C).
R IEC 584 1.8°F (1.0°C) -58°F to 3216°F (-50°C to 1769°C).
S IEC 584 2.5°F (1.4°C) -58°F to 3216°F (-50°C to 1769°C).
E IEC 584 0.7°F (0.4°C) -454°F to 1832°F (-270°C to 1000°C).
N IEC 584 1.1°F (0.6°C) -454°F to 2372°F (-270°C to 1300°C).
L DIN 43710 0.6°F (0.3°C) -328°F to 1652°F (-200°C to 900°C).
U DIN 43710 0.6°F (0.3°C) -328°F to 1112°F (-200°C to 600°C).
C 1.8°F (1.0°C) 32°F to 4208°F (0°C to 2320°C).
D 1.8°F (1.0°C) 32°F to 4523°F (0°C to 2495°C).
mV -10 to 100 mV.
General Specifications
0 to 55.000mA 0.02% reading + 3 count accuracy.
Temperature Coefficient 14°F to 50°F, 86°F to 122°F; 0.0011% FS/°F
(-10°C to 10°C, 30°C to 50°C; 0.002% FS/°C).
Switch Detection Open and closed. 2 mA current.
Loop Power Output 24 V ±10% (35 mA maximum).
HART mA Loop Resistor 250 Ω (menu selection).
Electrical Connectors 4 mm sockets.
Operating Temperature 14°F to 122°F (-10°C to 50°C).
Storage Temperature -4°F to 158°F (-20°C to 70°C).
Humidity 0 to 90% non-condensing, Def Stan 66-31, 8.6 CAT III.
Shock and Vibration BS EN61010:2001, Def Stan 66-31, 8.4 Cat III.
EMC BS EN61326-1:1998 + A2:2001.
Safety Electrical BS EN61010:2001. CE marked.
Display Graphic LCD with backlight. Resolution 99999.
Size (L x W x H) 7.1 in x 3.3 in x 2 in (180 mm x 85 mm x 50 mm).
Weight 14 oz (400 g).
Batteries 3 AA alkaline, >80 hours measure, 11 hours mA source
(24 V @ 12 mA).
Druck DPI 822 warranty One-year.

Download

Druck DPI 822 Datasheet

PDF Specifications of the Druck DPI 822 Thermocouple Loop Calibrator.

Download (411.58k)

No customer reviews for the moment.

Write your review

Druck DPI 822 Thermocouple Loop Calibrator
COMPONENT
DESCRIPTION PART No.
Carry Case Soft fabric carrying case with accessory pocket. IO800A
Meter Accessories Belt clip, wrist strap/hanging loop and bench stand. IO800B
Battery/Charger NiMh batteries with charger (charged externally). IO800C
IDOS Lead RS232 serial lead for IDOS. IO800D
Data Logging Data logging option with RS232 lead. IO800E

9 other products in the same category:

arrow_upward