loading spinner
Fluke 115 True RMS Multimeter
  • Fluke 115 True RMS Multimeter
  • Fluke 115 True RMS Multimeter
  • Fluke 115 True RMS Multimeter
  • Fluke 115 True RMS Multimeter

Fluke 115 True RMS Multimeter

Fluke authorised distributor and calibration house.

Includes: Fluke 115 Multimeter, 4 mm silicone test lead set, Rubber Boot, User Manual and 9V Battery.

2583583
£204.00
£244.8 Inc. VAT
In Stock

free fluke VoltAlert

The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. This true-rms meter provides easy one-handed operation in a compact package.

The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap.

FEATURES

Resistance, continuity, frequency, capacitance, and diode test.
Measures 10 A (20 A overload for 30 seconds).
Large white LED backlight to work in poorly lit areas.
Compact ergonomic design for one-handed operation.
Compatible with optional magnetic hanger (ToolPak™).
True-rms for accurate measurements on non- linear loads.
Min/Max/Average with elapsed time to record signal fluctuations.
CAT III 600 V safety rated.

Fluke 115 Specifications
Maximum voltage between any terminal and earth ground 600 V.
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2.
Display Digital - 6,000 counts, updates 4 per second.
Bar graph 33 segments, updates 32 per second.
Operating Temperature -10 °C to + 50 °C.
Storage Temperature -40 °C to + 60 °C.
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61.
Battery Life 400 hours typical, without backlight.
DC millivolts Range: 600.0 mV.
Resolution: 0.1 mV.
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2.
DC Volts Range/Resolution: 6.000 V / 0.001.
Range/Resolution: 60.00 V / 0.01 V.
Range/Resolution: 600.00 V / 0.1 V.
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2.
AC millivolts¹ true-rms Range: 600.0 mV.
Resolution: 0.1 mV.
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz).
AC volts¹ true-rms Range/Resolution: 6.000 V / 0.001 V.
Range/Resolution: 60.00 V / 0.01 V.
Range/Resolution: 600.0 V / 0.1 V.
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz).
Continuity Range: 600 Ω.
Resolution: 1 Ω.
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms Range/Resolution: 600.0 Ω / 0.1 Ω.
Range/Resolution: 6.000 kΩ / 0.001 kΩ.
Range/Resolution: 60.00 kΩ / 0.01 kΩ.
Range/Resolution: 600.0 kΩ / 0.1 kΩ.
Range/Resolution: 6.000 MΩ / 0.001 MΩ.
Accuracy: 0.9 % + 1.
Range/Resolution: 40.00 MΩ / 0.01 MΩ.
Accuracy: 5 % + 2.
Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2.
Capacitance Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%.
Lo-Z Capacitance Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical.
AC amps true-rms (45 Hz to 500Hz) Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30- seconds max.
DC amps Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30- seconds max.
Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2.
Dimensions 167 x 84 x 46 mm (6.57" x 3.31" x 1.82").
Weight 550 g.
Fluke 115 warranty 3 years.

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.

Download

Fluke 115 Datasheet

PDF Specifications of the Fluke 115 Digital Multimeter.

Download (801.07k)

No customer reviews for the moment.

Write your review

Fluke 115 True RMS Multimeter
COMPONENT PARTS DESCRIPTION PART No.
AC285 SureGrip™ Alligator Clip Set. 1610159
AC87 Heavy Duty Bus Bar Clip Set. 1278079
C90 Soft case for DMMs. 466029
TPAK ToolPak™ Magnetic Meter Hanger Kit including:
9 inch hook and loop strap
Universal hanger clip
Hook hanger for non magnetic surfaces
Strong magnet.
1281997
i400s
AC Current Clamp (400A). 2277202
TL220-1 SureGrip™ Industrial Test Lead Set including:
AC220 SureGrip™ Alligator Clip Set
TP220 SureGrip™ Industrial Test Probe Set
TL224 SureGrip™ Silicone Test Lead Set (straight to right)
One year warranty.
3971178
TL223-1 Electrical Test Lead Set. 3971184
TL71-1 Premium Test Lead Set. 3971207

16 other products in the same category: