- Hamilton01698 829711
- Leeds0113 235 1356
- Belfast02890 830302
Fluke 87V MAX/E2 Combo Kit
Includes: Fluke 87V MAX, C115 Soft Carrying Case, ToolPak™ Magnetic Meter Hanging Kit, TL224 SureGrip™ Insulated Test Leads, AC220 SureGrip™ Alligator Clips, TL238 SureGrip™ Test Probes, 80BK-A DMM Temperature Probe.
The Fluke 87V MAX True-rms Digital Multimeter defines a new standard for operating in extreme conditions with the features and accuracy to troubleshoot most electrical problems.
The 87V MAX has an IP67 (waterproof and dustproof) rating, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and has been designed and tested to withstand a 4 m (13 ft) drop. The Fluke 87V MAX True rms Digital Multimeter is built to work in the toughest environments you might face.
FEATURES:
True-rms ac voltage and current for accurate measurements on non-linear signals.
Measure up to 1000 V ac and dc.
Measure up to 10 A (20 A for 30 seconds).
Frequency to 200 kHz.
Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument.
Min/Max/Average recording, plus 150 μs Peak min-max to capture variations automatically.
Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs).
Large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility.
Hi resolution 20,000 count display mode.
Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits.
Safety rated CAT IV 600 V/CAT III 1000 V.
Long battery life (800 hours).
87V MAX | 87 V | |
IP Rating | IP 67 | IP 30 |
Battery life | 800 hours | 400 hours |
Drop test | 4 meters | 3 meters |
Backlit keypad | Yes | No |
TwistGuard™ test leads | Yes | No |
True-rms readings | ac | ac |
Basic dc accuracy | 0.05% | 0.05% |
Voltage ac/dc | 1000 V | 1000 V |
Current ac/dc | 10 A | 10 A |
Resistance | 50 MΩ | 50 MΩ |
EN61010-1 CAT III | 1000 V | 1000 V |
EN61010-1 CAT IV | 600 V | 600 V |
Warranty (years) | Limited lifetime | Limited lifetime |
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe. |
|
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater. |
|
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS. |
Min/Max/Avg | Yes. | |
Reading hold/Auto (Touch) Hold | Yes. | |
Relative reference | Yes. | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode. |
Analog bar graph | 32 segments, updates 40/second. | |
Backlight | Two level. | |
Low pass filter (VFD measurements) | Yes. | |
Input Alert™ | Yes. | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V. |
|
Agency approvals | CE, CSA. | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67. | |
Power | Three AA batteries. 800 hours typical, without backlight. | |
Size | 6.0 x 10.1 x 21.5 cm (with holster). | |
Weight | 698.5 g (with holster). | |
Fluke 87V MAX Warranty | Limited lifetime. | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C. | |
Storage temperature | -40 °C to + 60 °C. | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C). |
|
Operating altitude | 2000 m. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
Fluke C100 | Tough polyprophylene Universal Carrying Case. | 827055 | ||
Fluke C125 | Zippered carrying case with detachable external pouch. | 646858 | ||
Fluke TL175 | Patented TwistGuard™ test leads. Heavy-duty strain relief tested to 30,000+ bends without failure. | 352976 | ||
Fluke TL220 | Fluke TL220 SureGrip™ Industrial Test Lead Set. | 3971178 | ||
Fluke i400 | AC Current Clamp for your DMM to measure up to 400 A AC. | 2277225 | ||
Fluke 80K-40 | High voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts. | 382845 |