loading spinner
Fluke 87V MAX Digital Multimeter
  • Fluke 87V MAX Digital Multimeter
  • Fluke 87V MAX Digital Multimeter
  • Fluke 87V MAX Digital Multimeter
  • Fluke 87V MAX Digital Multimeter

Fluke 87V MAX Digital Multimeter

Fluke authorised distributor and calibration house.

Includes: Holster, TL175 TwistGuard® test leads, alligator clips, 80BK-A temperature probe, three AA batteries (installed).

5140033
£579.00
£694.8 Inc. VAT
In Stock

The Fluke 87V MAX True-rms Digital Multimeter defines a new standard for operating in extreme conditions with the features and accuracy to troubleshoot most electrical problems.

The 87V MAX has an IP67 (waterproof and dustproof) rating, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and has been designed and tested to withstand a 4 m (13 ft) drop. The Fluke 87V MAX True rms Digital Multimeter is built to work in the toughest environments you might face.

FEATURES:

True-rms ac voltage and current for accurate measurements on non-linear signals.
Measure up to 1000 V ac and dc.
Measure up to 10 A (20 A for 30 seconds).
Frequency to 200 kHz.
Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument.
Min/Max/Average recording, plus 150 μs Peak min-max to capture variations automatically.
Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs).
Large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility.
Hi resolution 20,000 count display mode.
Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits.
Safety rated CAT IV 600 V/CAT III 1000 V.
Long battery life (800 hours).

Comparison – 87V MAX and 87V
87V MAX 87 V
IP Rating IP 67 IP 30
Battery life 800 hours 400 hours
Drop test 4 meters 3 meters
Backlit keypad Yes No
TwistGuard™ test leads Yes No
True-rms readings ac ac
Basic dc accuracy 0.05% 0.05%
Voltage ac/dc 1000 V 1000 V
Current ac/dc 10 A 10 A
Resistance 50 MΩ 50 MΩ
EN61010-1 CAT III 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V
Warranty (years) Limited lifetime Limited lifetime
Fluke 87V MAX Specifications
Electrical Specifications
DC Voltage Range 0.1 mV to 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 0.1 mV
AC Voltage Range 0.1 mV to 1000 V
Accuracy ±(0.7% + 4) true-rms
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
DC Current Range 0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.1 µA
AC Current Range 0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) true-rms
Maximum resolution 0.1 µA
Resistance Range 0.1 Ω to 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Range 0.01 nF to 9999 μF
Accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Range 0.5 Hz to 199.99 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement range –200.0 °C to 1090 °C
–328.0 °F to 1994.0 °F
excluding probe.
80 BK temperature probe –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater
–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater.
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode test Range 2 V
Resolution 0.001V
Accuracy ±(1% + 1)
Diagnostics and data storage Peak Min/Max 250 μS.
Min/Max/Avg Yes.
Reading hold/Auto (Touch) Hold Yes.
Relative reference Yes.
Display Digital 6000 counts updates 4/second
19,999 counts in high–resolution mode.
Analog bar graph 32 segments, updates 40/second.
Backlight Two level.
Low pass filter (VFD measurements) Yes.
Input Alert™ Yes.
Safety Specifications
Safety rating IEC61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V.
Agency approvals CE, CSA.
Mechanical and General Specifications
IP rating IEC 60529: IP67.
Power Three AA batteries. 800 hours typical, without backlight.
Size 6.0 x 10.1 x 21.5 cm (with holster).
Weight 698.5 g (with holster).
Fluke 87V MAX Warranty Limited lifetime.
Environmental Specifications
Operating temperature -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C.
Storage temperature -40 °C to + 60 °C.
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C).
Operating altitude 2000 m.

Download

Fluke 87V MAX Datasheet

PDF Specifications of the Fluke 87V MAX Digital Multimeter.

Download (1.12M)

No customer reviews for the moment.

Write your review

Fluke 87V MAX Digital Multimeter
COMPONENT
DESCRIPTIONPART No.
C125 CaseZippered carrying case with detachable external pouch.646858
C550 Tool BagLarge zippered storage compartment with 25 pockets.1547919
TL175 LeadsTwistGuard™ Test Leads.3521976
TLK-225Fluke TLK-225 SureGrip™ Master Accessory Set.3971234
AC285 Alligator ClipsOne pair (red, black) of large alligator clips with nickel-plated steel jaws.1610159
AC/DC ClampFluke i1010 AC/DC Current Clamp.617735
i400 AC ClampCompanion to your DMM to measure up to 400 A AC.2277225
i410 AC/DC ClampBattery-powered Hall-effect probe measures 1A to 400 A.617727