loading spinner
Megger DET3TC Earth Testing Kit
  • Megger DET3TC Earth Testing Kit
  • Megger DET3TC Earth Testing Kit

Megger DET3TC Earth Testing Kit

Megger approved distributor and service centre.

Kit Includes: Three sets of leads, two test spikes, Megger DET3TC instruction manual CD, and a rugged carrying case.

DET3TC
Megger
£648.88
£778.656 Inc. VAT
In Stock

The Megger DET3TC is rated to IP54 making it truly an outdoor instrument. The ground tester has been designed to be easy to use - a large selector switch makes selection of 2 and 3 pole test easy with gloved hands. The DET3TC offers the solution for users who are concerned about the inherant dangers and potential cost implications of disconection of the earth spike.

In addition to ease of use, the ground tester also automatically checks the connection and condition of the P and C spike, indicating the status on the display. The instrument also includes a voltmeter to allow you to measure the ground voltage. The ground tester can measure resistance from 0.01Ω through to 2000Ω and earth voltages up to 100 V. To allow accurate testing in noisy environments the instrument is capable of rejecting noise of up to 40 V peak to peak.

The complete kit of instrument, test leads, stakes, batteries and calibration certificate are delivered in a tough polypropylene carry case - everything you need to start testing in one kit.

FEATURES

2 and 3 point testing.
ART (Attached Rod Technique) testing capability with DET3TC.
Choice of digital or analog display.
Warning indicators prevent test failure.
IP54 rated.
Complete with leads, stakes and rugged carry case.
Simple one button operation.
Calibration test certificate included.

Megger DET3TC Specifications
C spike check Automatic.
P spike check Automatic.
Noise check Automatic.
Noise rejection 40 V peak to peak.
2-wire test
3-wire test
No disconnect testing (ART) Yes, with optional ICLAMP.
Earth current range with ICLAMP 0.5 mA to 19.9 A.
Earth current accuracy 5% ±3 digits.
Resistance range
0.01 to 2000 Ω.
Resistance accuracy 2% ±3 digits.
Maximum probe resistance Rp limit: 100 kΩ (50 V output voltage)
Rc limit: 100 kΩ (50 V output voltage)
Limits reduced to 50 kΩ for 25 V output voltage
Limits reduced to 5 kΩ for 0.01 Ω resolution on 18 Ω range.
Earth voltage range 0 - 100 V a.c.
Earth voltage accuracy 2% ±2 V.
Display LCD.
Battery type 8 off AA cells.
Operating temperature range -15 to +55ºC.
Storage temperature range -40 to +70ºC.
Ingress protection IP54.
Safety IEC61010-1 CAT IV 100 V*
EN61557-1, EN61557-5.
EMC IEC61326-1.
Dimensions 203 x 148 x 78 mm (8 x 5.7 x 3.2 inches).
Weight 1 kg.
Megger DET3TC Warranty 3 years (after registration).
* The CAT IV 100 V rating is dependant on the use of a leadset of at least this rating, for example the optional two wire leadset part number 1001-858.

Download

Megger DET3TC Datasheet

PDF Specifications of the Megger DET3TC Digital Ground Tester.

Download (275.1k)

No customer reviews for the moment.

Write your review

Megger DET3TC Earth Testing Kit
COMPONENT
DESCRIPTION PART No.
Adaptors Right angled terminal adaptor set. 6220-803
Spikes 2 replacement earth test spikes (200 mm, 8 mm dia.). 6220-804
Leads 3 replacement test leads (15 m, 10 m, 3 m). 6220-805
Leads Leadset. 1001-858

16 other products in the same category: