Martindale THERMOKITLGN Legionella Testing Kit
Includes: DT173 single Input Thermometer Kit, 1 x penetration probe (TT6K), 1 x surface probe (TT8K), 1 x bead thermocouple (TT1P), hard carry case.
The Martindale ThermokitLGN includes the DT173 Thermometer with max function and two thermocouple probes in a hard carry case. The kit can be used for temperature testing and monitoring in accordance with Health & Safety Guidelines to avoid water temperature and conditions that can favour the growth of Legionella and other bacteria. The surface and immersion probes simplify measurement on pipework and tanks.
The DT173 comes with a protective rubberised holster and is switchable between °C and °F and between 1° and 0.1° resolution. Hold and maximum buttons allow the current value to be frozen or the maximum reading to be stored.
FEATURES
Temperature range -50°C to 1372°C (-58°F to 1999°F).
Thermocouple compensation adjustment.
Max / Min function.
Relative function.
Data hold function.
Backlight.
Auto power off.
Rubberised outer jacket.
Temperature accuracy | |
---|---|
Range | Accuracy |
-200°C to -60°C | 0.1% of rdg + 2°C. |
-60°C to 1372°C | 0.1% of rdg + 1°C. |
-328°F to -76°F | 0.1% of rdg + 4°F. |
-76°F to 1999°F | 0.1% of rdg + 2°F. |
Electrical | |
Temperature coefficient | 0.1 x (applicable accuracy) per °C. (0°C to 18°C, 28°C to 50°C). |
Temperature scale | Celsius or Fahrenheit, user-selectable. |
Thermocouple type | K. |
Measurement range | -200°C to 1372°C. (-328°F to 1999°F). |
Resolution | 0.1° to 199.9°C / °F, 1° ≥ 200°C / °F. |
Note: Measurement range will be limited by the range of the thermocouple probe used. | |
Input protection | 24V DC or AC rms maximum input voltage on any combination of input pins. |
Input connector | Accepts standard miniature thermocouple connectors (flat blades spaced 7.9mm. center to center). |
General Specifications | |
Display | 3½ digit liquid crystal display (LCD) with maximum reading of 1999. |
Measurement rate | 2.5 times/second. |
Polarity | Automatic, positive implied, ‘-‘ for negative polarity indication. |
Over-range | (OL) is displayed. |
Power | 4 x 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A). |
Battery life | 200 hours typical with alkaline batteries. |
Low battery indication | Low battery symbol is displayed. |
Auto power off | After minutes. |
Dimensions | 160 mm (H) x 83 mm (W) x 38 mm (D). |
Weight | Approx. 240g, including batteries. |
Environmental | |
Temperature & Humidity | (Operating): 0°C to 50°C, <70% R.H. (Storage): -20°C to 60°C, 0 to 80% R.H., batteries removed. |
Pollution degree | 2. |
Conforms to | BS EN 61010-1 50V. |
EMC | Conforms to BS EN 61326-1. |