loading spinner
Beha-Amprobe UAT-620-EUR
  • Beha-Amprobe UAT-620-EUR
  • Beha-Amprobe UAT-620-EUR
  • Beha-Amprobe UAT-620-EUR
  • Beha-Amprobe UAT-620-EUR

Beha-Amprobe UAT-620-EUR

beha-Amprobe Approved Distributor

Includes: UAT-600-R Receiver, UAT-600-T Transmitter, CC-UAT-600 Carrying Case, TL-UAT-600 Test Leads Kit (black test lead with detachable black alligator clip, red test lead with permanently attached red alligator clip, ground stake), SC-600 Signal Clamp, 2 x FP-UAT-600 Replacement Fuses, 6 x AA Batteries, 8 x D Batteries..

4994565
Beha-Amprobe
£3553.10
£4263.72 Inc. VAT

Avoid disruption with the rugged and durable Beha-Amprobe UAT-620-EUR, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet. Accidentally hitting an utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project

The locating kit comes complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses, all in a mobile, protective duffle bag. The UAT-620 kit also includes a Signal Clamp for transmitting a signal when it is not possible to make electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600 Transmitter in combination with the optional A-Frame accessory.

FEATURES

Multiple tracing modes allow you to locate and trace energised and de-energised utilities in a variety of applications.
The intuitive Transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 kHz frequencies.
The Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded and dark areas.
Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of the receiver sensitivity.
Measure voltage, resistance and output current.
Depth measurement up to 20 ft.
Rated CAT IV 600 V, ensuring safety when working with energised cables.
High-contrast display allows for clear viewing in full sunlight and features an automatic backlight for dark areas.
Rugged, durable construction: water and dust resistant to IP54 and drop proof to 3.28 ft (1 m).
Use the Signal Clamp to induce a signal without making electrical contact (included with the UAT-620).
Ground fault locating with the optional A-Frame accessory.

Beha-Amprobe UAT-600 Introduction

Beha-Amprobe UAT-600-EUR Contents Comparison Chart
UAT-610 Kit UAT-620 Kit
UAT-600-R Receiver    
UAT-600-T Transmitter    
CC-UAT-600 Carrying Case    
TL-UAT-600 Test Leads Kit    
FP-UAT-600 Replacement Fuse    
User Manual    
Quick Reference Guide    
6 x 1.5 V AA (IEC LR6) Batteries (Receiver, not installed)    
8 x D-Cell Batteries (Transmitter, not installed)    
SC-600 Signal Clamp  

Beha-Amprobe UAT-620 Specifications
Features UAT-600-R Receiver UAT-600-T Transmitter SC-600 Signal Clamp (included with UAT-620, optional for UAT-610)
Measurement category CAT IV 600 V.
Operating voltage/current 0 to 600 V. 0 to 600 V, 100 A max.
Operating frequency/tracing modes Active tracing: 33 kHz and 8 kHz
Passive tracing: 50/60 Hz and Radio.
Energised circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz and 33 kHz
Clamp mode: 8 kHz and 33 kHz
De-Energised circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi
A-Frame: 8 kHz
Clamp mode: 8 kHz and 33 kHz.
33 kHz and 8 kHz.
Locating modes Peak and Null
Depth measurement and accuracy Up to 20 ft
4 in to 10 ft: pm; 3 %
10 ft to 20 ft: pm; 5 %
Display backlight Automatic Yes
Audio indication Increasing closer to the signal Fast beeps showing the better signal is applied.
Transmitting mode power output Max. 3 watts.
Output voltage Max. 50 V rms.
Output current Max. 250 mA rms, constant current in 5 steps.
Signal voltage output (nominal) 23 V rms at 8 kHz
30 V rms at 33 kHz.
Mains voltage measurement 0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: pm; 10%
Resistance measurement
(De-energised circuit)
0 ohm; to 999 k ohm;
Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;)
Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;)
Accuracy: pm; 10%
Output hazardous voltage warning ≥ 30 V rms
Mains hazardous voltage warning ≥ 30 V rms
Sensitivity adjustment (gain control) Yes
Sensitivity at 1 m (typical) Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA
Display 4.3 in, 320 x 240 BW outdoor LCD display with auto backlight LCD display (LED backlight)
2.4 in x 1.3 in
Update rate Instantaneous Current (mA): 10 ms
Voltage (V): 15 ms
Resistance ( ohm;): 330 ms.
Operating temperature and humidity -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH.
Storage temperature and humidity -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH
Operating altitude < 6561 ft (< 2000 m)
Pollution degree 2
Water and dust resistance IP54
Drop proof 3.28 ft (1 m)
Power supply (6) 1.5 V AA alkaline batteries (8) 1.5 V D cell alkaline batteries.
Auto power off 15 minutes idle
Battery life Approx. 35 hours at 70 °F (21 °C) (Typical) Approx. 16 hours at 70 °F (21 °C) (Typical)
Overload protection 600 V rms
Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm
Safety compliance IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-031, CSA/UL 61010-031 (test leads)
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033.
Size (H x W x L) Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm) Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm) Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm).
Weight Approx. 4.2 lb (1.9 kg) (batteries installed) Approx. 7.0 lb (3.2 kg) (batteries installed) Approx. 1.9 lb (0.85 kg).

Download

UAT-600-EUR Series Datasheet

PDF Specifications of the UAT-600-EUR Series Underground Utilities Locator Kits.

Download (1.71M)

No customer reviews for the moment.

Write your review

Beha-Amprobe UAT-620-EUR
COMPONENT
DESCRIPTIONPART No.
SC-600-EuroSignal clamp for UAT-600 series.4994647
AF-600A-Frame cable ground fault locator.4994583
TL-UAT-600Test lead set for UAT-600 Series.4994446
CC-UAT-600EURCarrying case for UAT-600 Series.9027
FP-UAT-600Fuse, 2 pack for UAT-600 Series.4994468