Includes: carrying bag, 2 m safety leads with a HV plug at each end (one red and one blue), 2 m guarded safety lead with a HV plug at one end and a HV plug with a rear pick-up jack at the other end (black), 0.35 m guarded safety lead with a HV plug at one end and a HV plug with a rear pick-up jack at the other end (blue), 3 alligator clips (red, blue and black), 1.80-m mains power lead, user manuals on CD-ROM.
The Chauvin C.A 6505 megohmmeter is a portable instrument housed in a rugged field case with lid and operates on either battery or line power. It makes voltage, insulation, and capacitance measurements.
As soon as the switch is set to an insulation measurement position, the instrument automatically measures the presence of any AC/DC voltage. This voltage is measured at all times and indicated on the small display unit. The CA6505 automatically determines AC or DC: the AC measurement is an RMS value.
Insulation is sensitive to temperature and humidity variations. In addition, measurement is affected by the appearance of disturbance currents. To overcome these effects, long-term measurements must be performed and the PI and DAR coefficients must be calculated. They will then allow qualification of the insulants and their ageing.
FEATURES
Automatic voltage measurement,
Automatic detection of the presence of an external AC or DC voltage on the terminals.
Simple user interface,
Calculation of the PI and of the DAR.
Fuse protection of the instrument, with detection of a defective fuse.
Operator safety thanks to the automatic discharging of the device tested.
Automatic power-down of the instrument to extend battery life.
Indication of the battery charge condition.
Large backlit LCD display unit with many announciators for very easy reading.
Fixed test voltages | 500 V | 1000 V | 2500 V | 5000 V | |
Insulation ranges | 10 kΩ to 2 TΩ | 10 kΩ to 4 TΩ | 10 kΩ to 10 TΩ | 10 kΩ to 10 TΩ | |
Adjustable test voltage | 40 V to 5,100 V in 10 or 100 V increments. | ||||
Voltage | 1 to 5,100 V (15 Hz to 500 Hz or DC). | ||||
Capacitance | 0.001 to 49.99 F. | ||||
Leakage current measurement | 0.00 - 3mA. | ||||
Functions | |||||
Display | Large LCD screen. | ||||
Backlighting | |||||
Programmable alarms | No. | ||||
Smoothing of display | No. | ||||
Prog. test duration | |||||
Calculation of ratios | DAR - PI. | ||||
Step voltage mode | |||||
Calc. of R at reference T° | No. | ||||
Locking of test voltage | |||||
R(t) | No. | ||||
Storage | |||||
RS 232 | |||||
Printing of measurements | |||||
PC software | |||||
Power supply | Rechargeable NiMH battery. | ||||
Battery life | 30 days with 10 DARs and 5 PIs / day. | ||||
Electrical safety | IEC 61010-1 (Cat. III 1,000 V or Cat. I 2,500 V) and 61557. | ||||
Dimensions (L x W x H) | 270 x 250 x 180 mm. | ||||
Weight | 4.3 kgs. | ||||
Chauvin C.A6505 warranty | 12 months. |
No customer reviews for the moment.
COMPONENT |
DESCRIPTION | PART No. | ||
HV Lead Blue | HV Croc Lead, Blue 8m. | P01295214 | ||
HV Lead Red | HV Croc Lead, Red 8m. | P01295215 | ||
HV Lead Black | HV Large Croc Lead, Black, rear head pick up. 8m. | P01295216 | ||
HV Leads | HV Large Croc Lead, Blue, Red, Black. | P01295220 | ||
2x HV Leads | Set of 2 HV Simplified Leads. | P01295231 | ||
Bag | Standard Bag. | P01298066 |