loading spinner
Chauvin C.A 6555 15,000V Insulation Tester
  • Chauvin C.A 6555 15,000V Insulation Tester
  • Chauvin C.A 6555 15,000V Insulation Tester
  • Chauvin C.A 6555 15,000V Insulation Tester
  • Chauvin C.A 6555

Chauvin C.A 6555 15,000V Insulation Tester

chauvin arnoux authorised distributor.

Includes: Bag with 2 safety leads 3 m long equipped with an HV plug at each end (red / blue), 1 guard test lead 3 m long equipped with an HV plug at one end and an HV plug with rear connection at the other end (black), 3 crocodiles clips (red, blue, black), 2 CAT IV 1,000 V test probes (red/black) for voltage measurements, 1 blue lead with rear connection, 1 mains power cable 2 m long, DataView software, 1 optical / USB communication lead, 1 CA6555 operating manual in 5 languages on CD-ROM and 5 specification labels (1 per language).

P01139706
£3895.00
£4674 Inc. VAT

The Chauvin Arnoux C.A 6555 megohmmeter is a high-end portable measuring instrument intended for the measurement of very high electrical insulation and resistance values, mounted in a rugged site housing with a cover. It has a graphic screen and can operate on battery or mains power. The Chauvin C.A.6555 makes insulation measurements at voltages up to 15,000V.

Thanks to the large measurement range, extending up to 30 TΩ, the Chauvin C.A6555 meets the requirements of companies manufacturing cables, transformers, rotating machinery and medium-voltage generators, as well as professionals in the Electricity Transmission and Distribution sector. Specially adapted for checking insulation on rotating machinery with a 12 kV power supply or higher, the C.A 6550 complies with the IEEE43 standard which recommends testing insulation at 5-10 kV.

FEATURES

Wide measurement range from 10 kΩ to 30 TΩ.
Fixed or programmable test voltage from 40 V to 10/15 kV.
5 mA charging current.
Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs.
Automatic  calculation of DAR / PI / DD /∆R (ppm/V) ratios.
Multiple test modes: voltage ramp and step with “burning”, “early break” and “I-limit” modes.
3 filters to optimise measurement stability.
Calculation of R at a reference temperature.
Storage of 80,000 measurements and Real-time Clock.
Optically-isolated USB communication for transfer onto PC and report generation with the DataView® software.

Chauvin CA6550 & CA6555 Specifications
CA6550 CA6555
Test Voltages 10kV 15kV
Test Voltages Ranges 500 V: 10 kΩ to 2 TΩ
1000 V: 10 kΩ to 4 TΩ
2500 V: 10 kΩ to 10 TΩ
5000 V: 10 kΩ to 15 TΩ
500 V: 10 kΩ to 25 TΩ
15000 V: 10 kΩ to 30 TΩ.
Fixed Test Voltages 500 / 1,000 / 2,500 / 5,000 / 10,000 V 500 / 1,000 / 2,500 / 5,000 / 10,000 / 15,000 V
Variable Test Voltages 40 V - 10,000 V
3 Settable Voltage Values
40 V - 15,000 V
3 Settable Voltage Values.
Adjustment Increment
for Variable Voltages
Variable: 40-10 kV step : 40 V-1 kV: 10 V
1 kV-10 kV: 100 V
Variable: 40-15 kV step: 40 V-1 kV: 10 V
1 kV-15 kV: 100 V.
Ramp Mode 3 presettable ramps: start voltage / end voltage / duration.
Ramp Configuration Mode 40-1,100 V / 500-10,000 V 40-1,100 V / 500-15,000 V
Step Mode Up to 10 steps (value and duration con gurable for each step).
Voltage Measurement After Test AC: 0 – 2,500 V / DC: 0 – 4,000 V.
Capacitance Measurement 0.001-9.999 μF / 10.00-49.99 μF.
Leakage Current Measurement 0 - 8 mA.
Discharge After Test Yes/Automatic.
Additional Test Stop Modes I-limit Programmable: 0.2-5 mA.
Early Break di/dt.
Timer Up to 99 minutes 59 seconds.
Burning Mode Burning Constant Testing.
Ratio Calculation PI, DAR, DD.
Calulcation of R at ref. T° Yes.
Measurement Display Filter 3 Filters with 3 Possible Time Constant.
Graphs on Display R(t)+u(t); i(t); i(u);
Storage 256 recordings, 80,000 points : R, U, I and date.
Communication Optically-isolated port for USB and RS232 links.
PC Software DataView
Power Supply NiMH rechargeable batteries, 8x 1.2 V / 4,000 mAh
charging by external voltage: 90-260 V 50/60 Hz.
Battery Charging Battery charging possible while performing insulation measurements.
Electrical Safety 1,000 V CAT IV - IEC 61010-1 and IEC 61557.
EMC, Mechanical Protection, Altitude EN 61326-1 , IP54 , 3,000 m.
Dimensions LxWxH: 340 x 300 x 200 mm.
Weight 6.2 kg approx. (excluding accessories).
Chauvin CA6555 warranty One year.

Download

Chauvin CA6550-CA6555 Datasheet

PDF Specifications of the Chauvin Arnoux CA6550 & CA6555 10kV/15kV Insulation Testers.

Download (862.25k)

No customer reviews for the moment.

Write your review

Chauvin C.A 6555 15,000V Insulation Tester
COMPONENT
DESCRIPTION PART No.
HV Leads Set of 3 Cables - 3m HV Croc 10/15KV RD+BU+BK. P01295466
Large Croc Lead Blue 8M HV Croco 10/15KV Cable. P01295468
Large Croc Lead Red 8M HV Croco 10/15KV Cable. P01295469
Large Croc Lead Blue 15M HV Croco 10/15KV Cable. P01295471
Large Croc Lead Red 15M HV Croco 10/15KV Cable. P01295472
Large Croc Lead Black 15M HV Croco 10/15KV Cable. P01295473
Croc Clips Set of 3 crocodile clips: red/blue/black. P01103062
HV Lead 50 cm HV lead with rear connection. P01295467

2 other products in the same category:

arrow_upward