loading spinner
Megger S1-1068 10kV DC Insulation Resistance Tester
  • Megger S1-1068 10kV DC Insulation Resistance Tester
  • Megger S1-1068 10kV DC Insulation Resistance Tester

Megger S1-1068 10kV DC Insulation Resistance Tester

Megger approved distributor and service centre.

Includes: Megger S1-1068 10kV Insulation Resistance Tester, Safety Warning Sheet, Product information CD, includes PowerDB Lite, Power lead, Screened USB cable with filters, Remote control indicator beacon, Medium Test Clip 1002-531, Large Test Clip 1002-534 and calibration cert.

1003-008
Megger
£4890.00
£5868 Inc. VAT
In Stock

With class-leading noise rejection of 8 mA - twice that of most comparable instruments - and enhanced software filtering that has four user-selectable options, Megger’s S1-1068 10kV dc insulation resistance tester delivers dependable results in even the most severe of electrical environments, including high-voltage transmission and distribution substations.

Five preset voltage ranges are provided in insulation test mode, plus a user settable lock voltage range. Preconfigured diagnostic tests include Polarisation Index (PI), Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Stepped Voltage (SV) and Ramp test.

Other innovative features of the Megger S1-1068-UK include provision for remote control via a fully isolated USB port, which makes the instruments ideally suited for use in production environments, and internal storage for date-and time-stamped results. Stored results can be recalled to the display, downloaded via a Bluetooth wireless link or accessed via the USB port.

Megger S1-Series Accuracy
MODEL S1-568 5000V 2500V 1000V 500V 250V
±5% to 1 TΩ 500 GΩ 200 GΩ 100 GΩ 50 GΩ
±20% to 10 TΩ 5 TΩ 2 TΩ 1 TΩ 500 GΩ
MODEL S1-1068 10KV 5000V 2500V 1000V 500V
±5% to 2 TΩ 1 TΩ 500 GΩ 200 GΩ 100 GΩ
±20% to 20 TΩ 10 TΩ 5 TΩ 2 TΩ 1 TΩ
MODEL S1-1568 15KV 10KV 5000V 2500V 1000V
±5% to 3 TΩ 2 TΩ 1 TΩ 500 GΩ 200 GΩ
±20% to 30 TΩ 20 TΩ 10 TΩ 5 TΩ 2 TΩ
Megger S1-Series Specifications
AC Voltage (auto ranging)
S1-568, S1-1068 90 - 264 V rms, 50/60 Hz, 100 A.
S1-1568 90 - 264 V rms, 50/60 Hz, 200 A.
Battery Life
S1-568 6 hours (typical) continuous testing at 5 kV with a 100 MΩ load.
S1-1068 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load.
S1-1568 4.5 hours (typical) continuous testing at 15 kV with a 100 MΩ load.
30 min quick charge 1 hour operation at 5 kV with a 100 MΩ load.
Charge Time 2.5 hours deep discharge, 2 hours normal discharge.
Test Voltage 250 V, 500 V, 1000 V, 2500 V, 5000 V, 10000 V, 15000 V.
Lock Test Voltage 40 V to 1 kV in 10 V steps
1 kV to 5 kV in 25 V steps
5 kV to 15 kV in 25 V steps.
Test voltage Accuracy +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C
Resistance Range 10 k to 15 TΩ @ 5 kV
10 k to 35 TΩ @ 10 kV
10 k to 35 TΩ @ 15 kV.
Display Range Analogue 100 kΩ to 10 TΩ.
Display Range Digital 10 kΩ to 35 TΩ.
Short Circuit/charge Current 6 mA.
Insulation Test Alarm 100 kΩ to 10 GΩ.
Capacitor Charge (on battery) < 2.5 s/μF to 5 kV<br />
< 5 s/μF to 10 kV<br />
< 6.3 s/μF to 15 kV.
Capacitor Charge (with AC) < 1.5 s/μF to 5 kV<br />
< 2.7 s/μF to 10 kV<br />
< 4 s/μF to 15 kV.
Capacitance
Capacitor Discharge 5 kV to 50 V :< 120 ms/μF<br />
10 kV to 50 V:< 250 ms/μF<br />
15 kV to 50 V:< 3500 ms/μF.
Capacitance Range With test voltage set above 500 V.
S1-568: 10 nF to 25 μF<br />
S1-1068: 10 nF to 25 μF<br />
S1-1568: 10 nF to 50 μF.
Capacitance Measurement With test voltage set above 500 V.
S1-568: 10 nF to 25 μF<br />
S1-1068: 10 nF to 25 μF<br />
S1-1568: 10 nF to 50 μF.
Capacitance Measurement Accuracy 10 nF to 10 μF : ±10% ±5 nF.
Current Range 0.01 nA to 6 mA.
Current Accuracy ±5% ±0.2 nA at all voltages (23 °C).
Voltmeter Range 30 V to 660 V ac or dc, 45Hz – 65Hz.
Timer Range Up to 99 minutes 59 seconds
15 second minimum setting.
Memory Capacity 1 hrs logging @ 5 sec intervals.
Test Modes IR, IR(t), DAR, PI, SV, DD, ramp test.
Interface USB type B (device), Bluetooth® Class 2.
Real Time Output (V, I, R) readings at a rate of 1 Hz.
Remote Control Remote control via USB cable only (requires RC dongle to be in position).
Environmental
Operating Temperature -20 °C to 50 °C.
IP Rating IP65 (lid closed), IP40 (lid open).
Safety Meets the requirements of
IEC 61010-1
CATIV 600 V to 3000 m (5 kV, 10 kV)
CATIV 1000 V to 4000 m (15 kV).
EMC Meets the requirements of IEC61326-1.
Dimensions & Weight
Dimensions S1-568, S1-1068: 285 mm x 181 mm x 315 mm
S1-1568: 305 mm x 194 mm x 360 mm.
Weight S1-568, S1-1068: 4.5 kg
S1-1568: 6.5 kg.
Megger S1-1068 warranty Two-year.

Download

Megger S1-Series Datasheet

PDF Specifications of the Megger S1-568, S1-1068 & S1-1568 HV Diagnostic Insulation Testers.

Download (676.04k)

No customer reviews for the moment.

Write your review

Megger S1-1068 10kV DC Insulation Resistance Tester
COMPONENT
DESCRIPTION PART No.
CB101 5 kV Calibration Box. 6311-077
Transport Case Transport case - Large. 1009-744
HV Test Lead Set 3 x 5 m with medium insulated clips. 1002-641
HV Test Lead Set 3 x 8 m with medium insulated clips. 1002-642
HV Test Lead Set 3 x 10 m with medium insulated clips. 1002-643
HV Test Lead Set 3 x 15 m with medium insulated clips. 1002-644
HV Test Lead Set 3 x 5 m with large insulated clips. 1002-645
HV Test Lead Set 3 x 8 m with large insulated clips. 1002-646
HV Test Lead Set 3 x 10 m with large insulated clips. 1002-647
HV Test Lead Set 3 x 15 m with large insulated clips. 1002-648

5 other products in the same category: