Fluke 5609-9BND-X Secondary PRT

Fluke Calibration

Fluke Calibration authorised distributor.

The Fluke 5609 thermometer is classified as secondary standard. A secondary standard is used to transfer the ITS-90 from a standards laboratory to a customer’s laboratory.

More details

3116028

New

Delivery TBC

£ 793.00

(£ 951.60 inc VAT.)

Add to wishlist

The Fluke Calibration Platinum Resistance Thermometers (PRT) models 5608 and 5609, are designed to be a secondary standard interpolating instrument converting temperature to resistance. The PRTs are used with a readout device to detect temperature changes or actual temperature.

The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm.

The Fluke 5609-9BND-X probe has an Inconel™ sheath and is made using a special manufacturing process, giving it great precision over a wide temperature range. The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts.

In order for any instrument to be used as a standard it must be calibrated. These instruments are sold uncalibrated unless calibration is requested at time of purchase. They are satisfactory as secondary standards and may be calibrated by comparison to primary standards.

Please Note: When ordering please specify the termination you require. ie. Fluke 5609-9BND-G (gold pins).

X = termination.

Specify “A" (INFO-CON for 914X), “B" (bare wire), “D" (5-pin DIN for Tweener Thermometers), “G" (gold pins), “I" (INFO-CON for 1521 or 1522), “J" (banana plugs), “L" (mini spade lugs), “M" (mini banana plugs), “P" (INFO-CON for 1523 or 1524), or “S" (spade lugs).

FEATURES:

Secondary Reference PRT, 15 in x 1/4 in, 9 in bend, –200 °C to 670 °C, lead wire (cable) 6 ft.
Calibration not included.

Fluke 5609-9BND-X Specifications:

  • Temperature range: –200 °C to 670 °C.
  • Nominal resistance at 0.01: °C 100 Ω ± 0.5 Ω.
  • Temperature coefficient: 0.0039250 Ω/Ω/°C.
  • Short-term repeatability: ± 0.01 °C at 0.010 °C, ± 0.02 °C at max temp.
  • Sensor length: 30 mm ± 5 mm (1.2 in ± 0.2 in).
  • Sensor location: 3 mm ± 1 mm from tip (0.1 in ± 0.1 in).
  • Sheath dimensions, length x diameter 5608-9: 229 x 3.18 mm (9 in x 0.125 in).
  • Sheath diameter tolerance: ± 0.1 mm (± 0.004 in).
  • Sheath material: Inconel™ 600.
  • Transition junction temperature range: –50 ºC to 200 °C.
  • Minimum immersion length: 100 mm (3.9 in).
  • Maximum immersion length: 305 mm (12 in).
  • Response time: 12 seconds typical.
  • Lead-wire length: 1.8 m (6 ft).
  • Calibration: Not included.
  • Fluke 5609-9BND Warranty: 1 year.