Seaward Apollo 600 PAT Tester

Seaward Electronic

Seaward approved distributor and service centre.

Only the Seaward Apollo 600 integrates PAT testing with risk assessment so you can comply with the latest IET Code of Practice.

More details

380A 910

New

Usually Stock or Short Lead Time

£ 926.00 rrp £ 1,485.00

Save £ 559.00

(£ 1,111.20 inc VAT.)

Add to wishlist

With built-in risk assessment tools for any workplace hazard and a variety of testing and inspection reports including portable appliance testing, fire detection and emergency lighting; Apollo 600 offers an all-in-one solution to managing a risk-based approach to health and safety in any workplace, reducing the burden and ensuring compliance.

The Seaward Apollo600 also enables point to point testing of fixed appliances as required by the 4th edition of the IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment.

FEATURES:

Remote data transfer from field to office.
USB and Bluetooth data transfer.
Built in universal and electrical risk assessment tools.
High definition colour display.
On board colour camera with flash.
Point to point testing for fixed appliances.
Health and safety test and inspection forms including emergency lighting.
User tests for non-electrical tests and inspections.
Additional health & safety certificates.

Electrical Test Functions:

Low current earth continuity test guaranteeing accurate measurement.
Insulation resistance.
IEC lead test.
Protective conductor current.
Touch current.
Load power/current.
Alternative leakage current.
Point to point testing for fixed appliances.
RCD test.
Power socket test.

Seaward Apollo 600 Specifications
EARTH CONTINUITY
Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined
INSULATION RESISTANCE
Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined
IEC LEAD TEST
Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed
PROTECTIVE CONDUCTOR CURRENT/LOAD
Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined
TOUCH CURRENT
Test Voltage Supply Voltage, maximum load current 16A
Display Ranges 0.00 – 3.50mA
Pass Value User defined
LOAD POWER/CURRENT
Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads
Display Range 0.00kVA – 4.00kVA, 0.00A – 16.00A
ALTERNATIVE LEAKAGE CURRENT
Test Voltage >25VAC <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined
RCD TEST
Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms
Test method Internal isolation to avoid tripping distribution board RCD
POWER SOCKET TEST
Test Range 207V – 253Vac
Indicates configuration of voltage potential:-
Line potential phase to earth
Line potential phase to neutral
Line potential neutral to earth
GENERAL
Memory size 50,000 records & 2,000 photos
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack
Seaward Apollo600 warranty 2 years
Includes: Apollo checkbox, 2x test leads and probes with crocodile clips, 0.5m IEC lead, Mains power lead, USB download cable, 30 day free trial of PATGuard 3 Health and Safety Edition, Seaward Apollo600 Quick start guide, Carry case and Calibration Certificate.

SEAWARD APOLLO 600 VIDEO

Write a review

Seaward Apollo 600 PAT Tester