T&R PCU2 Mk5 Primary Current Injection System

T&R Test Equipment

T&R Approved distributor and service company.

The PCU2 Mk5 primary current injection system is ideally suited to commissioning and maintenance testing where very high currents are required.

More details

X129A

New

Add to wishlist

The PCU2 from T&R Test Equipment is a primary current injection system designed to be used in conjunction with a T&R Test Equipment loading transformer. Depending on the loading unit used, currents up to 6000A are available for 5 minutes and 12kA for 1 second.

The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables.

The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs
which may be connected in series or parallel for maximum flexibility. For example, the LU6000 may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V.

The output current is metered by a digital memory ammeter with an LED display. The current reading is continuously updated when the output is energised, and the value held when the
output is de-energised.

The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be
positioned as close as possible to the test object, minimising power requirements and maximising the available current.

The PCU2 mk5 and loading units are CE marked and are designed to meet the requirements of BS EN61010.

FEATURES

20kVA 5 minute output capability.
Continuously variable output.
Multi-function timing system.
Digital true RMS ammeter with memory.
Bright LED displays.
Automatic switch-off at end of test.
Centralised control and metering.
Separate control and loading units.
5000A (10kA 1s) & 6000A (12kA 1s).
Low impedance, dual-range outputs.

T&R PCU2 Mk5 Specifications:

T&R PCU2 Mk5 specifications

  • Timer resolution: 1ms.
  • Timer full scale: 999.999s.
  • Timer accuracy: ±0.01% rdg + 2d, ±0.01% rdg + 3d current operated mode.
  • Contact O/C voltage: 24V.
  • Contact S/C current: 100mA.
  • VDC input range: 24-240V DC.
  • Supply requirements: 230V, 49-61Hz, 1ph, 23kVA for 5mins, 46kVA for 1 second.
  • Storage temperature: -20°C to 60°C.
  • Operating temperature: 0°C to 45°C.
  • Control unit dimensions: 660 x 400 x 740mm
  • Control unit weight: 115kg.
  • T&R PCU2 Mk5 warranty: 1 year.

Includes: Spare fuse set, operating manual. 1 x 5m loading unit power interconnection lead. 1 x 5m loading unit metering interconnection lead. 1 x 2m mains lead.

Write a review