loading spinner
Fluke 773 Milliamp Process Clamp Meter
  • Fluke 773 Milliamp Process Clamp Meter
  • Fluke 773 Milliamp Process Clamp Meter
  • Fluke 773 Milliamp Process Clamp Meter

Fluke 773 Milliamp Process Clamp Meter

Fluke authorised distributor and calibration house.

Includes: Four AA alkaline batteries (installed), Soft carrying case, TL75 test leads, AC 72 detachable clip, TL 940 mini hook test leads, Fluke 773 Instruction sheet, Hanging tool with hook and loop strap.

3362365
£1145.00
£1374 Inc. VAT
In Stock

The Fluke 773 is designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.

The hand-held, battery-operated Fluke 773 Milliamp Process Clamp Meter can be used in troubleshooting transmitters, valves, PLC and DCS I/O. Unlike conventional clamp meters, the Fluke 773 features a remote jaw that is connected to the main body via extension cable.

The 773 also sources and measures dc voltage, so it can be used to troubleshoot voltage input and output devices. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.

FEATURES

DC voltage measurement to verify 24 V power supplies or voltage I/O signals.
Source dc voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal.
Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp.
mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal.
Voltage output linear ramp or 25 % step output.
Automatically changes the 4 to 20 mA output for remote testing.
Data hold function.
Auto off and backlight timeout extend battery life.
Built-in measurement spotlight for illuminating darkened areas.

771, 772 & 773 Functions
mA Measure
w/jaw
mA Measure
In Circuit
mA Source mA Sim Loop Power
24 V
DC V Source
0 - 10 V
DC V Measure
0 - 30 V
Scaled mA Output
to mA Input
mA In/Out
Fluke 771
Fluke 772
Fluke 773
Fluke 773 Specifications
Diameter of measurable conductor 0.177” or 4.5 mm max.
Operating temperature -10 to 50 ºC.
Storage Temperature -25 to 60ºC.
Operating Humidity < 90% @ <30 ºC, < 75% @ 30 to 55ºC.
Operating Altitude 0 to 2000 m.
IP Rating IP 40.
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in).
Weight 410 g, (14.4 oz).
Vibration Random 2 g, 5 to 500 Hz.
Shock 1 meter drop test (except the jaw).
EMI/RFI Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient 0.01% ºC
(<18ºC or > 28ºC).
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms.
Warranty Three years for electronics one year for cable and clamp assembly.
Functional Specifications
mA measurement
(Measured by clamp)
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2% + 5 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts.
mA measurement
(Measured in series with test jacks)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.
Voltage source
(2 mA maximum drive current)
Resolution and Range: 0 to 10.00 V DC
Accuracy: 0.2% + 2 counts.
Voltage measure Resolution and Range: 0 to 30.00 V DC.
Accuracy: 0.2% + 2 counts.

Download

Fluke 772+773 Datasheet

PDF Specifications of the Fluke 772 & 773 Milliamp Process Clamp Meter.

Download (938.28k)

No customer reviews for the moment.

Write your review

Fluke 773 Milliamp Process Clamp Meter

2 other products in the same category: