Martindale HPAT600/2 PAT Tester
  • Martindale HPAT600/2 PAT Tester
  • Martindale HPAT600/2 PAT Tester
  • Martindale HPAT600/2 PAT Tester
  • Martindale HPAT600/2 PAT Tester

Martindale HPAT600/2 PAT Tester

martindale approved distributor

Includes: HPAT 600/2, instructions, Mains Charger Unit, Car Charger, Test Probe with crocodile clip (TL67), 6 x AA NiMH rechargeable batteries, Adaptor Lead (EX332), Null Pin on keyfob.

MARHPAT600/2
£349.00
£418.8 Inc. VAT
In Stock

The Martindale HPAT600/2 is an easy to use battery powered, hand held PAT tester that is ideal for testing all types of portable appliances. The tester is supplied with rechargeable batteries for low running costs and a mains and in-car charger for convenience. Whilst recharging, the HPAT can still be operated from the mains supply ensuring maximum productivity at all times.

The HPAT600/2 can be operated in either of two test modes. In the Manual test mode, aimed at the newcomer to PAT testing, a connection diagram for the selected test type is shown on the display. Each step of a test type requires confirmation by a press of the OK button. In the Auto test mode, for the experienced operator, the HPAT600 will automatically run through a selected test type without any further user interaction unless a failure is encountered.

A null function is incorporated in the HPAT600/2 to compensate for the test probe lead resistance when used for Class I earth continuity measurements. This allows for alternative test probes to be used if desired.

The HPAT600 stores test data for up to 200 appliances which can be easily reviewed on the instrument if you need to check a result on site. It also has a simulated load test to check the load and ensure that the appliance is switched on with a good fuse. The HPAT600/2 has a new high contrast backlit display.

The HPAT600/2 will perform the following test types:

IEC Lead test sequence.
Class I test sequence.
Class II test sequence.
Simulated Load test.
Class I Earth Continuity single test.
Class I Insulation single test.
Class II Insulation single test.

FEATURES

Easy to use automatic and manual testing.
Displays measured values with clear PASS/FAIL indication.
Class I, Class II & power lead tests.
I.T. safe 200mA DC earth bond test with two pass levels.
250V insulation test option for surge protected devices & sensitive IT equipment.
Test both 240V and 110V appliances.
Rechargeable with both mains and in-car chargers included.
Memory with on-screen recall for 200 sets of results.

Martindale HPAT500 & HPAT600 Product Video

Martindale HPAT Comparison Chart
HPAT400 HPAT500/2 HPAT600/2
Class I /II Test
Lead Test
Pass/Fail Indication
Test Values Displayed -
Selectable Limits - -
Test Mode Auto Auto Auto/Manual
Run Test - - Simulated
Earth Continuity Test Current 200 mA 200 mA 200m A
Insulation Test Voltage 500 V 250/500 V 250/500 V
110V Appliances With accessory With accessory With accessory
Memory - - 200 results for on-screen recall
Supply Alkaline batteries Rechargeable Rechargeable
Martindale HandyPAT600/2 Specifications
Earth Continuity
Test Voltage 4 V DC (into open circuit).
Test Current 200 mA DC (into short circuit).
Range 0 - 19.99 Ω.
Resolution 0.01 Ω.
Accuracy ± (5% reading + 2 digits).
Default PASS Levels (Class I) 0.1 Ω.
Default PASS Levels (Lead) 0.1 Ω.
User Selectable Pass Levels 0.1 Ω to 0.9 Ω in 0.1 Ω steps.
Insulation
Test Voltage (500 V Range) >500V DC at 1mA ( < 600V DC into open circuit).
Test Voltage (250 V Range) >250V DC at 1mA ( < 300V DC into open circuit).
Test Current 1.5mA (into short circuit).
Ranges 2.00MΩ, 20.0MΩ, 200MΩ.
Resolution 0.01MΩ.
Accuracy ± (5% reading + 2 digits).
Default Pass Level (Lead) 1 MΩ.
Default Pass Level (Class I) 1 MΩ.
Default Pass Level (Class II) 2 MΩ.
User Selectable Pass Levels 0.3 MΩ to 1 MΩ in 0.1 MΩ steps
1 MΩ to 10 MΩ in 1 MΩ steps.
Fuse Test
Test Voltage 4 V DC (into open circuit).
Test Current 200 mA DC (into short circuit).
Pass Level >2 mA.
Simulated Load Test
Test Voltage 4 V DC (into open circuit).
Test Current 200 mA DC (into short circuit).
Accuracy ± (5% reading + 2 digits) (referenced to 230 V).
General
Memory Completed test types that can be stored: 200.
Overload Protection 300 V AC/DC.
Protection Class IP20.
Safety Complies to BS EN 61010-1:2001.
Temperature Range -10 to 40°C, non-condensing.
Power Supply 6 x 1.2 V AA NiMH rechargeable batteries
1800 mAh, or greater.
Dimensions 90 x 210 x 54 mm.
Weight Approx 700g (including batteries and leads).

Download

Martindale HPAT600 Datasheet

PDF Specifications of the Martindale HPAT600 Handheld PAT Tester.

Download (37.27k)

No customer reviews for the moment.

Write your review

Martindale HPAT600/2 PAT Tester
COMPONENT
DESCRIPTION PART No.
Earth Bond Lead Heavy duty earth bond lead with single 4mm banana plug connection, compatible with the Martindale HPAT500 & HPAT600. MARTL68
TL151 4 pin, 16A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. MARTL151
TL152 5 pin, 16A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. MARTL152
TL153 4 pin, 32A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. MARTL153
TL154 5 pin, 32A 3 phase socket to UK mains plug, allows testing of earth bond and insulation from PAT testers. MARTL154
EX331 110V Extension Lead Adaptor, use with PATs that have the IEC lead test built in to test 110V extension leads. MAREX331
PAT Register Book A5 register to keep manual records of PAT testing results for up to 315 appliances to ensure your system is fully compliant. MARPATREG