Martindale HPAT500 Basic Manual PAT Tester

Martindale Electric

Martindale approved distributor and service centre.

The HPAT500 is a battery powered, hand held PAT tester with simple one-button test selection.

More details

MARHPAT500

New

Usually Stock or Short Lead Time

£ 359.20 rrp £ 449.00

save 20%

(£ 431.04 inc VAT.)

Add to wishlist

The Martindale HPAT500 is a battery powered, hand held PAT tester with simple one-button test selection. It is ideal for use where there is no convenient power socket and provides a time saving solution when adopting a mobile approach to PAT testing.

Unlike similar PAT testers, the HPAT500 has a unique feature to counteract issues with testing appliances with long leads, or long extension leads, caused by the extra resistance added as a result of the lead length.

FEATURES

Simple One Button Operation.
Automatic Class I, Class II & power lead tests.
Pass / Fail Tester with Result.
I.T. safe 200mA DC earth bond test with two pass levels.
Rechargeable Batteries & Charger Included.
Low Current Bond Test for Sensitive IT Equipment.
Tests both 240V and 110V appliances.
Mains rechargeable with in-car option.
Ideal for Low Volume Testing.

Martindale HPAT500 Specifications:

  • Earth Continuity Test voltage: 4V DC (into open circuit).
  • Test current: 200mA DC (into short circuit).
  • Range: 0 - 19.99Ω.
  • Resolution: 0.01Ω.
  • Accuracy: ± (5% of reading + 2 digits).
  • Insulation Fixed voltage: >500V DC at 1mA (< 600V DC into open circuit).
  • Test current: 1.5mA (into short circuit).
  • Ranges: 2.00MΩ, 20.0MΩ, 200MΩ.
  • Resolution: 0.01MΩ.
  • Accuracy: <100MΩ ± ( 5% reading + 2 digits), >100MΩ ± ( 10% reading + 2 digits).
  • Fuse check Test voltage: 4V DC (into open circuit).
  • Test current: 200mA DC (into short circuit).
  • Pass level: >2mA.
  • Overload protection: 300V AC/DC.
  • Battery Life: Fully charged, minimum 600 complete tests.
  • Auto Power Down: After 10 minutes of inactivity, or when battery low.
  • Output: 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive.
  • Protection class: IP20.
  • Safety: Complies to BS EN 61010-1: 2001.
  • Dimensions: 90 x 210 x 54mm.
  • Weight: Approx 700g (including batteries & leads).
  • Martindale HPAT500 warranty: 2 years.

Includes: HPAT 500, Earth Bond Probe with Croc Clip, Calibration Certificate, 6 x 1800mAh NiMH Rechargeable Batteries, Mains Battery Charging Adaptor, 240V Extension Lead Adaptor, Soft Carry Case with Strap, Printed Instruction Manual.

Battery Powered Yes
IT Safe Yes
Handheld Yes

Write a review