loading spinner
Chauvin PEL103 Promo
  • Chauvin PEL103 Promo
  • Chauvin PEL103 Promo
  • Chauvin PEL103 Promo
  • Chauvin PEL103 Promo

Chauvin PEL103 Promo

chauvin arnoux authorised distributor.

Includes: 4 measurement leads (straight banana / straight banana - 3 m long - black), 4 crocodile clips (black), 3 MA193 mini-AmpFLEX sensors (cable length 3 m), 1 SD card (2 GB), 1 SD-USB adapter, 1 set of inserts (ends of leads and current sensors), 1 mains power cable (1.8 m long - 250 V), 1 USB cable (Type A / Type B - 1 m long), 1 Multifix mounting systems, 1 operating manual (on CD), 1 bag & 1 safety datasheet.

P01299956
Call For Price

Chauvin PEL103 Promotion

Buy a Chauvin PEL103 Power logger and get a self-powering mains adapter, MA193-200 MiniFlex Clamps, Chauvin Arnoux Kit Bag (including Magnetised Probes and Reeling Boxes), Chauvin Arnoux DataView® Software and an Android Tablet FREE whilst stocks last (RRP £2654).
Offer may be withdrawn at any time.


The Chauvin Arnoux PEL 102 and PEL 103 loggers are power and energy measurement loggers for all electrical installations. The measurements are performed with 3 current sensors and voltage inputs. They can be used to view all the electrical parameters and to take advantage of the measurement, energy metering and communication functions.

The PEL100 family of energy meters makes it simple to add metering and measurement points in electrical cabinets where most of the space is already occupied. Because they are magnetic, they can be set up very easily in any cabinet and do not cause any obstruction once the cabinet door is closed.

When installed for a long period in a cabinet, the PEL103 logger constantly monitors the active, apparent and reactive power values on the electrical network involved. This means they will instantly detect whenever the subscribed power threshold is exceeded.

With the software for automatically generating and printing reports, balance sheets, graphs or DataView® summaries, users can act quickly on the cause of this overconsumption which will lead to higher bills. Indeed, every time your subscribed power threshold is exceeded, your bill will increase.

FEATURES

Direct measurements of voltages up to 1000 V CAT III and 600 V CAT IV.
Direct measurements of current from 50 mA up to 10 000 A with MA193 external current sensors.
Power measurements: active (W), reactive (var) and apparent (VA).
Energy measurements: active (source and load (Wh)), reactive 4 quadrants (varh) and apparent (VAh).
Power Factor (PF), cos φ, and tan Φ.
Crest Factor.
Total Harmonic Distortion (THD) for voltages and currents.
Harmonics from the fundamental signal up to the 50th order for 50/60 Hz voltages and currents.
Frequency measurements.
RMS and DC measurements @ 128 samples/cycle – all phases simultaneously.
Bright white triple LCD display on PEL 103 (3 phases shown simultaneously).
Storage of measured and calculated values on an SD-Card or SDHC-Card.
Automatic recognition of the different types of current sensors.
Configuration of current and voltage ratios with external sensors.
Supports 17 types of connections or electrical distribution systems.
USB, LAN, and Bluetooth communication.
PEL Transfer software for data recovery, configuration and real-time communication with a PC.

Chauvin Arnoux PEL Product Video

Chauvin Arnoux PEL103 Specifications
Model 103
Display Triple digital display.
Installation types Single-phase, split-phase, three-phase with or without neutral and many other specific configurations.
Number of channels 3 voltage inputs / 3 current inputs (calculation of neutral current).
Measurements
Network frequency 50 Hz, 60 Hz & 400 Hz.
Voltage (measurement ranges / best accuracy) ± 0.2 % + 0.5 V.
Current (depending on sensor)
(measurement ranges / best accuracy)
5 mA ac to 10 kA ac / 50 mA dc to 1.4 kA dc / ±0.5 %.
Calculated Measurements
Ratio Up to 650,000 V / up to 25,000 A.
Power 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA.
Energy Up to 4EWh / 4 EVAh / 4 Evarh.
Phase cos φ, tan Φ, PF.
Harmonics Up to the 50th order.
Complementary Functions
Phase order Yes.
Min/max Yes.
Mounting Magnet, hook.
Recording
Sampling / Acquisition rate / Aggregation 128 S/period - 1 measurement per second - from 1 min to 60 min.
Memory SD card 2 GB (SD-HC up to 32 GB).
Communication Bluetooth (Class 1), Ethernet, USB.
Power supply 110 V - 250 V (+ 10%, - 15 %) @ 50-60 Hz & 400Hz.
Safety IEC 61010 CAT IV 600 V and CAT III 1,000 V.
Casing
IP54, UL (pending).
Mechanical
Dimensions 256 x 125 x 37 mm without sensor.
Weight 950 g.
Chauvin PEL103 warranty 3 year.

Download

Chauvin PEL100 Series Datasheet

PDF Specifications of the Chauvin Arnoux PEL102 & PEL103 Power Loggers.

Download (1.75M)

No customer reviews for the moment.

Write your review

Chauvin PEL103 Promo
COMPONENT
DESCRIPTION PART No.
A193-450 AmpFlex 450mm, 1...10kA, single, Black. P01120526B
A193-800 AmpFlex 800mm, 1...10kA, single, Black. P01120531B
MN93A AC, 0.5...200A clamp, single, Black. P01120434B
Adapter Mains adapter to power PEL using voltage inputs. P01102134
Kit 4 Crocodile clips and banana leads. P01295476
Bag no.23 120 x 300 x 60cm. P01298078
Battery Rechargeable battery pack. HX0086

5 other products in the same category: